Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2003.11a
- /
- Pages.840-844
- /
- 2003
Flow Analysis for Design Modification of Marine Generator Fan
박용 발전기 냉각 팬 설계변경에 따른 유동해석
- Published : 2003.11.05
Abstract
A study for increase of fan flow rate by geometric modification has been conducted to decrease temperature rise of marine generator inner part. Through experiment of a real product, a performance curve for various flow resistances was obtained. Flow analyses for each cases were done by using commercial code-FLUENT and the results were very similar to experimental data (0.7% deviation at normal operating condition). Through flow analysis results for various design geometric modification, a scroll type fan was adopted as a best design geometry with 100Pa more pressure and 22% more flow rate than original fan.