Non destructive test of Fire-damaged reinforced concreted beams with high strength concrete

화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 비파괴 검사

  • Published : 2003.11.01

Abstract

Non-destructive testing is essential in the inspection of alteration, repair and new construction in construction industry. This paper is to evaluate the strength variation of fire damaged concrete by non-destructive testing. Furthermore, It is to infer the recovery degree of residual strength of fire-damaged concrete. For this purpose, researchers are exploring the performance of non-destructive testing method using ultrasonic testing and Schmidt hammer in concrete specimens. Testing is performed four-times: before fire test, directly after fire test, after 20 days and after 60 days.

Keywords