Calculation and Measurement of Column Shortening High-Rise RC Structure

초고층 RC구조의 기둥축소량 해석 및 현장계측

  • 이성원 (삼성물산㈜ 건설부문 갤러리아 팰리스 현장) ;
  • 박현일 (삼성물산㈜ 건설부문 갤러리아 팰리스 현장) ;
  • 김원식 (삼성물산㈜ 건설부문 갤러리아 팰리스 현장) ;
  • 오정근 (삼성물산㈜ 건설부문 기술연구소)
  • Published : 2003.05.01

Abstract

Axial shortenings of wall and columns were measured on level 2 and precise leveling between wall and columns were surveyed on level 5 at the Galleria Palace structure. Measured and surveyed shortening values were compared with the analysis results at the earlier stage on the process of construction for evaluating the predicted values. Though measured values represent relatively low and scattered values at earlier construction stage, probably they show similar slope curves to predicted ones with the progress of time.