Uniform deformation and Critical Current properties of 500 m class Bi-2223/Ag HTS tapes

500 m급 Bi-2223/Ag 고온초전도 선재의 균일 가공 및 임계전류 특성

  • 이동훈 (한국전기연구원 초전도응용연구그룹) ;
  • 양주생 (한국전기연구원 초전도응용연구그룹) ;
  • 최정규 (한국전기연구원 초전도응용연구그룹) ;
  • 윤진국 (한국전기연구원 초전도응용연구그룹) ;
  • 황선역 (한국전기연구원 초전도응용연구그룹) ;
  • 김상철 (넥상스코리아(주) 기술연구소) ;
  • 하홍수 (한국전기연구원 초전도응용연구그룹) ;
  • 하동우 (한국전기연구원 초전도응용연구그룹) ;
  • 오상수 (한국전기연구원 초전도응용연구그룹)
  • Published : 2003.02.01

Abstract

Intermediate annealing was carried out during wire drawing for uniform deformation of 500 m class Bi-2223/Ag HTS tapes. Wire drawing force was measured to evaluate the uniformity of wire deformation along the length. To prevent sausage and filament breakage of wire, drawing stress was controlled below 200 MPa by using intermediate annealing process. Thickness and width of the rolled tapes was measured 0.23 mm and 4.1 mm with low deviation $\pm$ 0.08 mm and $\pm$ 0.09 mm, respectively. The critical current of the 500 m tapes was measured 33.7 A $\pm$ 3.7 A by continuous critical current measurement system.

Keywords