초록

Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity etc.. In this paper we analyze P/S potential and axial current of the pipeline with CP systems using BEM and DC traction stray current influences on buried pipelines.