Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2001.06d
- /
- Pages.738-743
- /
- 2001
Performance Design Analysis of the Bottoming System of Combined Cycle Power Plants
복합화력발전 하부시스템의 성능설계해석
Abstract
A computer program, capable of performing thermal design analysis of the triple pressure bottoming system of combined cycle power plants, was developed. The program is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. The program is applicable to various parametric analyses including optimized design calculation. This paper presents examples of analysis results for the effects of arrangement of heat exchanger units, steam pressures and deaerating sources on design performance indices such as steam turbine power and the size of heat recovery steam generator.
Keywords