Performance Design Analysis of the Bottoming System of Combined Cycle Power Plants

복합화력발전 하부시스템의 성능설계해석

  • 이봉렬 (서울대학교 대학원 기계공학부) ;
  • 김동섭 (인하대학교 기계공학과) ;
  • 노승탁 (서울대학교 기계항공공학부) ;
  • 신흥태 (현대건설(주) 기술연구소) ;
  • 전용준 (현대건설(주) 기술연구소)
  • Published : 2001.06.27

Abstract

A computer program, capable of performing thermal design analysis of the triple pressure bottoming system of combined cycle power plants, was developed. The program is based on thermal analysis of the heat recovery steam generator and estimation of its size and steam turbine power. The program is applicable to various parametric analyses including optimized design calculation. This paper presents examples of analysis results for the effects of arrangement of heat exchanger units, steam pressures and deaerating sources on design performance indices such as steam turbine power and the size of heat recovery steam generator.

Keywords