Experimental Study of the pressure characteristics in the Stirling refrigerator

스터링 냉동기의 압력특성에 관한 실험적 연구

  • 홍용주 (한국기계연구원 열유체환경연구부) ;
  • 박성제 (한국기계연구원 열유체환경연구부) ;
  • 김효봉 (한국기계연구원 열유체환경연구부) ;
  • 고득용 (한국기계연구원 열유체환경연구부)
  • Published : 2001.11.01

Abstract

The linear compressor have been widely used for pressure wave generation in the Stirling cryocooler and Stirling type pulse tube cryocooler for tactical purpose. The linear compressor has small and compact structure, and long life due to having non-contact sealing mechanism. and the pressure drop through regenerator was ver important role in the motion of displacer in the expander of the Stirling cryocooler. In this study, the characteristic of the linear compressor and the pressure drop through regenerator in the expander was experimentally investigated. The results show the resonance of the compressor is very important to get maximum performance. and the gas spring force in the compression space of the compressor has effect on the characteristic of reonance. and the results show the pressure drop through regenerator is very small than operating pressure change.

Keywords