Atmospheric and Pressurized Operation of a 25 kW MCFC Stack

25 kW급 용융 탄산염 연료 전지 스택의 상압 및 가압 운전

  • 고준호 (한전 전력연구원 발전연구실 연소신발전그룹) ;
  • 서혜경 (한전 전력연구원 발전연구실 연소신발전그룹) ;
  • 임희천 (한전 전력연구원 발전연구실 연소신발전그룹)
  • Published : 2000.04.20

Abstract

As a part of the ongoing effort towards commercial application of high-temperature fuel cell power generation systems, we have recently built a pilot-scale molten carbonate fuel cell power plant and tested it. The stack test system is composed of diverse peripheral units such as reformer, pre-heater, water purifier, electrical loader, gas supplier, and recycling systems. The stack itself was made of 40cells of $6000cm^2$ area each. The stack showed an output higher than 25kW power and a reliable performance at atmospheric operation. A pressurized performance was also tested, and it turned out the cell performance increased though a few cells have shown a symptom of gas crossover. The pressurized operation characteristics could be analyzed with numerical computation results of a stack model.

Keywords