대한기계학회:학술대회논문집 (Proceedings of the KSME Conference)
- 대한기계학회 2000년도 춘계학술대회논문집B
- /
- Pages.13-18
- /
- 2000
판형 열교환기에 대한 전자식 스케일 완화 장치의 성능평가
Performance Evaluation of Electronic Scale Mitigation Unit for Plate Heat Exchanger
- 발행 : 2000.04.20
초록
The objective of the Present study is to investigate the performance of electronic scale mitigation unit(ESMU), which reduces the amount of scale in a heat exchanger. A plate heat exchanger with 20 thermal plates is used for the tests. In order to accelerate the rate of fouling in a laboratory test artificial hard water of 2000 ppm(as