Design of Energy Absorbing Braces

가새형 소성변형감쇠기의 설계 방법에 관한 연구

  • 김진구 (성균관대학교 건축공학과) ;
  • 이강준 (성균관대학교 건축공학과)
  • Published : 2000.10.01

Abstract

Unbond brace hysteretic dampers are generally used to prevent or decrease structural damage in buildings subjected to strong earthquake by its energy dissipating hysteretic behavior. According to a previous research, the optimum ratio of device yield strength to story yield strength of the combined system has been identified as the most important parameter for characterizing the performance of this device. In this research, the validity and the applicability of the previous research has been investigated and a new approach has been proposed through earthquake response analysis of a steel structure installed with unbond brace type hysteretic damper.