A Study on Seismic Performance of Spiral Prer

나선철근교각의 내진성능에 관한 연구

  • 배성용 (정회원, 영남대 토목공학과) ;
  • 김광수 (정회원, 영남대 토목공학과) ;
  • 이형준 (정회원, 한국도로공사 책임연구원) ;
  • 이재훈 (정회원, 영남대 토목공학과)
  • Published : 2000.04.01

Abstract

The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. However, The current seismic design requirements for bridges are based on the USA seismic codes for sever earthquake. This provides the basic factors that affects the performance of spiral reinforced concrete piers for seismic loading, and The specimen tests are performed based on load-displacement, effective stiffness and displacement ductility, etc. The quasi-static test was adopted in order to investigate seismic performance of the spiral reinforced concrete pier specimens which had different transverse steel amount, spacing and longitudinal steel ratio under different axial load levels. This study is concluded that seismic design for transverse reinforcement content of spiral reinforced concrete column has influenced on axial load and effective stiffness etc.