Study on The Preventive Structure of field Lead Connector's V-Notch on Synchronic

동기발전기 회전자 계자접속부의 예각변형 방지구조에 관한 연구

  • Published : 2000.07.17

Abstract

The preventive structure of field lead connector's V-notch on synchronous generator has been developed. The preventive structure of field lead, installed in the generator, prevent from V notch of field lead connector in rotor on daily start and stop (on-line). This development of study was performed at the Seoinchon combined cycle power plant on gas turbine generator. This preventive structure of field lead will be prevent from V-notch of field lead on synchronous generator's field.

Keywords