Investigation of the Causes of Uncooled Region Induced at Top End in Wire Rolling Process

선재압연에서의 소재선단 미수냉부 발생원인 규명

  • Son, Boong-Ho (Instrumentation & Control Research Group, POSCO) ;
  • Yoo, Jea-Sang (Instrumentation & Control Research Group, POSCO)
  • 손봉호 (포항종합제철 기술연구소 계측제어연구그룹) ;
  • 유재상 (포항종합제철 기술연구소 계측제어연구그룹)
  • Published : 2000.07.17

Abstract

In order to reduce the trimming loss for water cooling zone next to finishing block mill in wire rolling, the operational data related to the crop length control of uncooled region was acquired and analyzed. The time deviation of water cooling spray nozzles and the immoderate preset length of uncooled wire rod result in the excessive trimming loss. Therefore, the preset length of uncooled wire rod at each cooling zone are established. The test results of #3 wire rolling mill turned out to be good enough to be expected to increase the ratio of products about 0.15% and establish operational standards of cooling zone.