A New Switching Strategy for The Output Current Control of Inverters

인버터 출력 전류제어를 위한 새로운 스위칭 방법

  • Published : 1999.11.20

Abstract

It is necessary to obtain the high performance of the inverter system that control the output current of inverters. The dead time causes detrimental effects to the control performance of the inverter system. So we need to compensate the dead time effects. And the dead time minimization switching method can be considered as the best way to avoid the dead time effects fundamentally. In this paper, a new dead time minimization switching strategy is proposed. According to the proposed method, very short dead time is adopted in only once when the current polarity is changing. And the adopted dead time is equal to the applied dead time or shorter than it. As the proposed method can be done with the porlarity information of the reference current. it is easy to avoid some problems in comparison with the case that the real current is used to get the polarity changing time; level detection difficulty, noise problem and so on.

Keywords