Behavior of High-Strength Concrete Columns by Longitudinal Reinforcement Ratio and Eccentric Distance
주근비와 편심거리에 따른 고강도 콘크리트 기둥의 거동
Abstract
With increasing use of high-strength concrete tied columns in structural engineering, it becomes necessary to examine the applicability of related sections of the current design codes. This experimental study was conducted to investigate the behavior of eccentrically loaded high-strength concrete columns. Column specimens with concrete strength 234, 437, 703kgf/㎠ were tested under monotonically increasing eccentric compression. The test parameters included the longitudinal reinforcement ratio, eccentric distance and concrete compressive strength. The analytical results obtained from the stress-strain relationship and the ACI's equivalent rectangular stress block are compared with experimental test results.
Keywords