콘크리트의 촉진염소이온 확산 시험법에 관한 연구

A Study for the Accelerated Chloride Diffusion Test of Concrete

  • 이용은 (한국도로공사 도로연구소 책임연구원, 이학박사) ;
  • 김진철 (한국도로공사 도로연구소 연구원) ;
  • 이찬영 (한국도로공사 도로연구소 연구원)
  • 발행 : 1999.04.01

초록

An electrci method for the rapid determination of chloride diffusion coefficient in concrete is proposed considering the electrical migration term in the Nernst-Plank equation. The experimental set-up for this method is basically that for PD index by Dhir, excluding some change in the experimental parameter values in consideration of reliability, simplicity and rapidity of the accelerated test method. Experimental results show that 30mm of specimen thickness, 10 volt of supplied potential, and 5M of chloride ion concentration are optimal

키워드