The Cooling Effect of Pipe Cooling in Mass Concrete Structures

매스 콘크리트 구조물의 파이프 쿨링에 의한 냉각효과

  • 오병환 (서울대학교 토목공학과) ;
  • 신경준 (서울대학교 토목공학과 대학원) ;
  • 차수원 (서울대학교 토목공학과 대학원)
  • Published : 1999.04.01

Abstract

Cracking of concrete is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal cracking is a recurring concern in the production of concrete structures in particular when large, massive structures are considered. Thremal stresses arise from the differential temperature distribution either within s sturcture or between newly cast sectons and adjoining older parts. There are many different methods of reducing thermal stresses. A method often used for reducing temperature within a structure, is to cool the inner core with embedded cooling pipes. In this study, finite element method is employed for thermal analysis of concrete structures. To calculate water temperature variation in pipe, the conservation of thermal energy in internal flow was adopted. The cooling effect of pipe cooling is studied with several factors like convective coefficient, water temperature, concrete heat characteristics

Keywords