Temperature Crack Contol in Subway Box Structures

지하철 박스 구조물에서의 온도균열제어

  • 구본창 (쌍용양회공업(주) 중앙연구소 콘크리트연구실) ;
  • 김동석 (쌍용양회공업(주) 중앙연구소 콘크리트연구실) ;
  • 하재담 (쌍용양회공업(주) 중앙연구소 콘크리트연구실) ;
  • 김기수 (쌍용양회공업(주) 중앙연구소 콘크리트연구실) ;
  • 최롱 (쌍용양회공업(주) 중앙연구소) ;
  • 오병환 (서울대학교 토목공학과)
  • Published : 1999.04.01

Abstract

The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as underground box structure, mat-slab of nuclear reactor buildings, dams or large footings, foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, pre-cooling which lowers the initial temperature of fresh concrete with ice flake, pipe cooling which cools the temperature of concrete with flowing water, design change which considers steel bar reinforcement, operation control and so on. The objective of this paper is largely two folded. Firstly we introduce the cracks control technique by employing low-heat cement mix and thermal stress analysis. Secondly it show the application condition of the cracks control technique like the subway structure in Seoul.

Keywords