Mock-up test for the comparison of hydration heat the thermal stress in different types of cements

시멘트 종류별 수화열 및 온도응력 비교를 위한 모형타설 실험 연구

  • 김상철 (동아건설산업(주) 책임연구원) ;
  • 이두재 (동아건설산업(주)) ;
  • 강석화 (동양중앙연구소 건설재료연구실장) ;
  • 김진근 (한국과학기술원 토목공학과)
  • Published : 1998.04.01

Abstract

Recent construction method in mass concrete structures would depend on the control of hydration heats and thermal stresses by using the low heat cement, optimized block size and a lift height, or both. This experimental study aims at the possibility of thermal cracks according to the different types of cementations material and at the investigation of these effects. Four different types of cements are applied to the mock-up test and are evaluated in terms of temperature rises and thermal stresses with the use of thermocouples, strain gauges and effective stress gauges. As a result of this study, it was found that stresses measured from effective stress gauges agree well with ones form strain gauges, and the trend of stress occurrence can be well evaluated from theoretical analysis.

Keywords