Retrofitting of Reinforced Concrete Wall to Increase Axial Load Capacity

벽체의 축력 증진 방안 연구

  • Published : 1997.10.01

Abstract

The main structural system of domestic apartments is the wall-slab system. In such structures, the lack of material strength of wall affects severely on the safety of structures. It is fond frequently that the wall in the apartment structures has lower strength in concrete than the specified. This paper presents the retrofitting method of the reinforced concrete wall with low concrete strength. The tests are performed to investigate the structural behavior and the effects of external reinforcing and thickness increasing on the axial load capacity of walls. Six specimens are tested. As the test results, the external reinforcing method is less effective than thickness increasing method.

Keywords