A Study on the Development of a Ultra-Strength Precast Concrete Bearing Concrete Bearing Plate

초고강도 ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$) P.C Bearing Plate 개발에 관한 연구

  • 소현창 (정회원, 현대산업개발(주) 기술연구소) ;
  • 정병욱 (정회원, 현대산업개발(주) 기술연구소, 소장) ;
  • 김재우 (정회원, 현대산업개발(주) 기술연구소) ;
  • 문성규 (정회원, 현대산업개발(주) 기술연구소)
  • Published : 1997.04.01

Abstract

P.C Bearing Plate method, corresponding to the existing steel plate build-up method, is developed by the very first in domestic and is applied to the foundation in the HYUNDAI building at Kang-Nam. P. C Bearing Plate produced in ourself P.C plant can stand against vertical load of 7,000ton obtaining allowable force of soil. It is possible to minmize cost expediting, do site assembling and omit unnecessary excavation work by plant prefabrication of foundation member. The purpose of this paper is to study the optimum mixing design of Ultra-high strength concrete ($\acute{f}_{C91}$= 950kg/$\textrm{cm}^2$), crack control through measuring the heat of hydration, mock up test for the optimum curing method. As mentioned above, developing the Ultra-high strength Precast Concrete Bearing Plate set up successfully in the site foundation work of the HYUNDAI Building at Kang-Nam.