An Experimental Study on Static Test of Linear Induction Motor(I)

선형유도전동기의 정특성에 대한 실험적 연구(I)

  • Published : 1996.07.22

Abstract

This paper deals with experimentation on static test of linear induction motor for the propulsion system of UTM(Urban Transit Maglev). It is very important that vertical force zero effects to levitation field of maglev. Because it is continuous for air gap 11mm of levitated maglev vehicle. Then we found the slip frequency that the vertical force zero due to it is variable. Thus we had compared between simulation value and experiment value for lim by static test Jig.