Effects of Seismic Isolated Frequency in Structural Responses of Cylindrical Tanks

면진주파수가 원통형탱크의 구조응답에 미치는 영향

  • Published : 1995.10.01

Abstract

For design of seismic isolated system the determination of isolated frequency is very important. In this paper the effects of seismic isolated frequency for cylindrical tank are investigated using the 1940 EL Centre earthquake(NS). From the results of analysis the seismic isolated frequencies significantly depend on input acceleration and displacement components in lower frequency regions. Therefore, the seismic isolated frequency should be determined by consideration of input ground motion characteristics. For the seismic analysis the modified hysteretic hi-linear model of seismic isolators which can consider the yield load variation, shape of hysterisis loop variation and hardening effects of isolators is proposed. The analyses using the proposed model give similar displacement responses but higher maximum acceleration responses than those using the simple hysteretic hi-linear model.

Keywords