Dynamic Characteristics of LIM controlled by constant V/f

V/f일정제어로 제어되는 LIM의 동특성

  • Published : 1995.07.20

Abstract

This paper deals with the dynamic characteristics of LIM which is controlled by constant V/f ratio and the characteristics of the Inverter acted as interface between the utility power system and LIM. Though open-loop control method is less reliable than closed-loop control method, it's commonly used because it is simple and cheap. This paper shows the consideration for dynamic characteristics of LIM under open-loop control and for Inverter.

Keywords