부착 안된 부분 P.C 슬래브의 해석

Analysis of Partially Prestressed Concrete Slab without bond

  • 박흥용 (명지대학교 토목공학과) ;
  • 최익창 (명지대학교 토목공학과) ;
  • 연준희 (명지대학교 토목공학과)
  • 발행 : 1990.10.01

초록

This paper introduced truss model and one-way slab elastic Model to analyse flexure of unbonded prestressed concrete member. After cracking, we could determine concrete membrane depth, deflection and stress. In order to do that, an numerical example of simply supported one way slab which has non-external membrane support(s=0) is analysed. The analytical results using the analytical model were compared with several experimental results and were generally satisfied.

키워드