Voltage Clamping 회로를 첨가한 다중 인버어터의 구동에 관한 연구

A study on the multi-inverter drive that is including the voltage clamping circuit

  • 발행 : 1988.07.01

초록

The induction motor is constantly operated by general source, thus its speed control is employed an inverter system which can convert DC into AC. The CSI(Current Source Inverter) which have a commutation capacitor in its circuit is liable to cause a voltage spike that it is due to charge and discharge of commutation capacitor. And six phases inverter makes a number of harmonics. These have a effect upon the induction motor badly. This paper aims to suggest a way to reduce such adverse effects by maximally cutting the voltage spike as well as by eliminating a number of harmonics through the operation of Multi-HFCSI.

키워드