• 제목/요약/키워드: zone cooling

검색결과 316건 처리시간 0.021초

사무소용 건물의 냉방시스템 운전에 관한 수치적 연구 (A Numerical Study on the Operation of Cooling System in an Office Building)

  • 이승우;민만기
    • 대한설비공학회지:설비저널
    • /
    • 제17권6호
    • /
    • pp.686-695
    • /
    • 1988
  • An algorithm and a computer program were developed for the operational simulation of office building cooling system. Using this computer program, the following results were obtained. ${\bullet}$ There is a critical number of coil rows in AHU with which the cooling system can be operated in maximum efficiency. ${\bullet}$ Energy conservation can be achieved in an office building through TAB(Testing Adjusting and Balancing) of zone air volumes.

  • PDF

Estimating the Air Temperature Cooling Effect of the Cheonggyechun Stream Restoration Project of Seoul, Korea

  • Park Chong-Hwa;Kwon Young-Sang
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • 제2호
    • /
    • pp.120-129
    • /
    • 2004
  • Urban stream restoration projects can improve water quality, wildlife habitats, urban landscape, outdoor recreation spaces, and urban microclimate. The objectives of this research were to investigate temperature cooling effect of urban streams by using satellite imagery, to evaluate environmental variables related to stream cooling effect, and to estimate the cooling effect of the Cheonggye stream restoration project of Seoul, Korea. Findings of this research can be summarized as follows. First, a method of estimating temperature distribution around urban streams by using satellite imagery was developed. Scatter plots of distance from stream edges and average temperature obtained through multiple buffering were used for the estimation. Second, urban temperature cooling effect of streams was estimated by comparing background temperature and temperature of each buffer zone. Third, environmental factors affecting stream cooling effect were also identified. Fourth, the temperature cooling effect of the restoration project was estimated based on three scenarios. An estimated cooling effect based on the average cooling effect of existing tributaries showed the most significant effect; $2.0^{\circ}C$ lower than the present level at the edge of the renovated stream. It was estimated that the temperature of the same area would be $1.4^{\circ}C$ cooler than the present level if the cooling effect of the Yangjaechun was used as the bench mark But the effect would be $1.2^{\circ}C$ lower than the present level if environmental variables related to the temperature cooling effect of urban streams were used as the bench mark.

  • PDF

선회연소기를 이용한 산소부화연소화염의 연소 특성 연구 (Characteristics of Oxygen-Enhanced Flame in Swirl Burner)

  • 이윤원;안국영;김한석;이창언
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.149-154
    • /
    • 2001
  • The emission characteristics, flame stability, the composition of the flame zone and temperature profile were studied experimentally. The compositions of oxydant were varied by substituting $N_2$ with $CO_2$ at the constant $O_2$ concentration. Results showed that flame became unstable due to the high heat capacity, low transport rate and strong radiation effect of $CO_2$ in comparison with those of $N_2$. The reaction zone was cooled, broadened, as the conversion ratio of $CO_2$ to $N_2$ was increased. Temperature has a large effect on the NOx emission. The concentration of NOx in flue gas decreased due to the decreased temperature of reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the conversion ratio of $CO_2$ to $N_2$ was increased, the emission of CO and the higher temperature zone increased due to the decrease of reaction rate by the cooling effect.

  • PDF

온실내 근권부의 지중냉각부하 추정 (Estimation of Soil Cooling Load in the Root Zone of Greenhouses)

  • 남상운
    • 생물환경조절학회지
    • /
    • 제11권4호
    • /
    • pp.151-156
    • /
    • 2002
  • 지중냉각이나 양액냉각과 같은 근권부 냉각은 뿌리의 활력 증진, 양수분 흡수력의 향상, 작물체온의 강하 및 고온스트레스의 감소 등에 효과가 있는 것으로 알려져 있으며, 또한 온실 전체를 냉방하는것 보다 경제적이다. 따라서 본 연구에서는 지중냉각시스템을 경제적인 고온극복 방법중의 하나로 생각하고, 기술을 체계화하기 위한 시도로 지중냉각시스템의 열전달 특성을 분석하여 냉각부하를 산정하기 위한 실험을 수행하였다. 지중열류 측정자료로부터 힘수비에 따른 토양의 열전도율을 분석하였으며, 함수비 19~36%의 범위에서 열전도율은 0.83~0.96W.m$^{-}$.$^{\circ}C$$^{-}$로 직선적인 증가를 보였다. 일사량, 지표온도 및 기온의 관측치로부터 일사량에 따른 지표온도 상승을 회귀분석한 결과 거의 직선적인 관계를 보였으며, 지표온도는 실내 수평면 일사량 300~800W.m$^{-2}$ 범위에서 작물이 없는 경우 3.5~7.$0^{\circ}C$,작물이 지표면을 거의 덮고 있는 경우 1.0~2.5$^{\circ}C$ 정도 기온보다 상승하는 것으로 나타났다. 실험자료를 이용하여 온실의 설계기온과 냉각설정 지온, 일사량 및 토양의 함수비에 따른 지중냉각시스템의 냉각부하를 구하였다. 실내일사량 300~600W.m$^{-2}$ , 토양함수비 20~40%의 범위에서 기온과 지온의 차이를 1$0^{\circ}C$로 유지하기 위해서는 46~59W.m$^{-2}$ 의 냉각열량이 필요한 것으로 나타났다. 보다 정확한 설계자료의 구축을 위해서는 다양한 조건별 실험을 추가로 수행해야 할 것으로 생각된다.EX>$\mu$$_{r}$′) and the dielectric loss ($\varepsilon$$_{r}$"/$\varepsilon$$_{r}$′) were increased. It was caused that the absorption characteristics of the absorber were improved. The conduction loss and magnetic loss were expected to be occurred together because two matching frequencies were shown with carbon addition. It was confirmed that the matching frequency of the microwave absorber could be controlled by controlling heat-treatment temperatures and carbon additions.ons.tions.加的)으로 되거나 과가황(過加黃)이 될 우려가 있는 제조공정(製造工程)에서는 흔히들 이 방법(方法)을 무시(無視)하고 있다. 여기서 강조(强調)해 두어야 할 것은 항상 제품(製品)의 외부(外部)를 완전(完全)히 가황(加黃)시킬 필요(必要)는 없다는 것이다. 다공성(多孔性)이나 기포생성(氣泡生成)을 조장(助長)하는 불량가황상태(不良加黃狀態)와 표면(表面)에서의 과가황상태간(過加黃狀態間)의 균형(均衡)을 취(取)해 줘야 하는데 물론(勿論) 이때는 가황시간(加黃時間)을 단축(短縮)시켜야 한다는 경제적(經濟的)인 측면(側面)도 아울러 고려(考慮)해야 한다. 이것은 고무기술자(技術者)가 당면(當面)해야할 과제(課題)

자동차용 엔진 냉각시스템의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of Automotive Engine Cooling Control System)

  • 박경석;원종필;정동화
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1183-1194
    • /
    • 1998
  • This paper describes a theoretical model developed for analyzing the heat transfer of automotive cooling systems. From the model, heat transfer rate of automotive cooling systems can be predicted, providing useful information at the early stages of the design and development. The aim of the study is to develop a simulation program for automotive cooling system analysis and a performance analysis program for analyzing heat exchanger. Heat release rate from combustion gas to coolant through cylinder wall in engine cylinder was analyzed by using a two zone combustion model. This paper studied how cooling condition would affect engine heat release rate and measured temperature distribution of coolant in water jacket.

데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안 (Analysis and Improvement of Cooling System for Energy Saving in Data Center Building)

  • 장용호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

Bloom 연주기의 최적 냉각조건 도출을 위한 응고 시뮬레이션 (Solidification Simulation for Optimal Cooling of Bloom Type Continuous Casting Machine)

  • 정영진;김영모;조기현;강충길
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1629-1636
    • /
    • 2004
  • The continuous casting is primarily a heat-extraction process in which the heat transfer at various cooling zones profoundly influences quality of products. So development of numerical model is necessarily needed for more specific and clear investigations upon heat transfer mechanism at mold and secondary cooling zones. In this study, heat transfer coefficients which show the characteristic of heat transfer mechanism in mold are calculated for more exact analysis with temperature measured in bloom mold using optimal algorithm, and finally the validity of cooling conditions at secondary cooling zone actually used at field fur 30 Ton bloom type continuous casting of 0.187%C is investigated. From the results of solidification analysis, the characteristic of bloom mold shows a similar tendency with that of previous studies, and optimized cooling conditions for 0.187%C are presented.

Application of Cathodic Protection on Metallic Structure in Extremely Acidic Fluids

  • Chang, H.Y.;Yoo, Y.R.;Jin, T.E.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권4호
    • /
    • pp.140-146
    • /
    • 2005
  • Fossil fired power plant produces the electric energy by using a thermal energy by the combustion of fossil fuels as like oil, gas and coal. The exhausted flue gas by the combustion of oil etc. contains usually many contaminated species, and especially sulfur-content has been controlled strictly and then FGD (Flue Gas Desulfurization) facility should be installed in every fossil fired power plant. To minimize the content of contaminations in final exhaust gas, high corrosive environment including sulfuric acid (it was formed during the process which $SO_2$ gas combined with $Mg(OH)_2$ solution) can be formed in cooling zone of FGD facility and severe corrosion damage is reported in this zone. These conditions are formed when duct materials are immersed in fluid that flows on the duct floors or when exhausted gas is condensed into thin layered medium and contacts with materials of the duct walls and roofs. These environments make troublesome corrosion and air pollution problems that are occurred from the leakage of those ducts. The frequent shut down and repairing works of the FGD systems also demand costs and low efficiencies of those facilities. In general, high corrosion resistant materials have been used to solve this problem. However, corrosion problems have severely occurred in a cooling zone even though high corrosion resistant materials were used. In this work, a new technology has been proposed to solve the corrosion problem in the cooling zone of FGD facility. This electrochemical protection system contains cathodic protection method and protection by coating film, and remote monitoring-control system.

딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향 (Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry)

  • 권진경;강석원;백이;문종필;장재경;오성식
    • 생물환경조절학회지
    • /
    • 제28권1호
    • /
    • pp.46-54
    • /
    • 2019
  • 히트펌프와 냉온수 배관을 이용한 촉성재배 '설향' 딸기의 관부와 근권부에 대한 국소 냉난방 시험과 정식 전 딸기묘의 단근처리 시험을 수행하였다. 정식(2017년 8월 31일) 후 주간의 관부 표면온도는 국소냉방구가 $18{\sim}22^{\circ}C$로 화아분화에 적합한 온도를 유지한 반면 무처리구와 근권부 냉방구는 화아분화 한계온도인 $25^{\circ}C$를 상회한 $30^{\circ}C$ 이상으로 나타났다. 정식 후 30일 경과 시의 생육조사 결과 국소냉방처리 간의 생육차이는 없었으며 단근처리묘에서 초장과 엽병장이 상대적으로 작았으나 전체적으로 지상부의 생육저하는 크지 않은 것으로 나타났다. 국소냉방 및 단근처리에 대한 화방출뢰율을 조사한 결과 정화방 출뢰율은 구입묘를 제외하고 단근처리묘와 비단근처리묘에서 모두 관부 국소냉방구, 근권부 국소냉방구, 대조구의 순서로 높게 나타났으며, 대조구, 근권부 국소난방구, 관부 국소난방구 모두에서 단근처리묘가 비단근처리묘에 비해 높게 나타났다. 정화방 출뢰율은 관부 국소난방구 단근처리묘가 가장 높았으며 가장 낮은 무처리 비단근처리묘 보다 시기별 최대 3.8배 높게 나타났다. 1차 액화방의 출뢰율은 처리구 간 차이가 정화방에 비해 크지 않으나 정화방과 동일한 경향을 나타내었다. 2018년 3월 27일까지의 상품과 수확량은 구입묘를 제외하고 관부 국소난방구, 근권부 국소난방구, 대조구의 순서로 나타났으며, 단근처리묘가 비단근처리묘보다 수확량이 높았다. 이러한 경향은 2018년 2월 14일까지의 정화방 중심의 초기수확량에서 뚜렷하게 나타났으며 2018년 3월 9일부터 국소냉방과 단근처리의 영향은 줄어드는 것으로 나타났다. 난방시험의 경우 근권부 국소난방구(근권 $20^{\circ}C$+공간 $5^{\circ}C$)와 관부 국소난방구(관부 $20^{\circ}C$+공간 $5^{\circ}C$)는 대조구(공간 $9^{\circ}C$) 대비 각각 59%와 65%의 난방유 절감이 가능하였으며, 히트펌프 가동에 의한 전기소비를 반영하였을 때 난방비는 각각 55%와 61%가 절감되는 것으로 분석되었다. 히트펌프와 배관을 이용한 촉성재배 '설향' 딸기의 관부 국소냉난방은 초기수확량 증가와 난방에너지절감 효과를 확인할 수 있었으나 화아분화 촉진에 의한 화방출뢰의 조진화는 정식시기, 환경조건, 초기생육이 미치는 영향이 크므로 이와 관련한 추가적인 연구가 필요한 것으로 판단되었다.

증발 냉각방식을 이용한 딸기 수경재배의 배지 온도조절 기술 개발 (Development of Temperature Control Technology of Root Zone using Evaporative Cooling Methods in the Strawberry Hydroponics)

  • 김기동;하유신;이기명;박대흠;권순구;박종민;정성원
    • 생물환경조절학회지
    • /
    • 제19권4호
    • /
    • pp.183-188
    • /
    • 2010
  • 본 연구는 딸기의 수경재배에서 증발냉각방식을 이용하여 배지의 지하부 온도를 관리할 수 있는 냉각시스템을 개발하고 고온기 온실내 기온에 따른 배지내 온도분포 특성을 분석하고자 다공질 필름 덕트법, 배지 상면 기습부직포 멀칭법, 투수부직포 재배조 표면 증발법의 3가지 냉각시스템에 대하여 배지냉각특성을 시험하였다. 그 결과 투수부직포 재배조 표면 증발법의 경우 온실내 기온 $35^{\circ}C$인 배지표면의 온도와 상대습도 50%일 때 재배조 표변의 부직포의 온도는 $27^{\circ}C$로 니타났으며, 뿌리가 많이 분포되어 있는 배지내 온도는 $28{\sim}30^{\circ}C$ 정도로 나타나 외기온에 비하여 $5{\sim}7^{\circ}C$ 정도로 기장 크게 강하되었다. 따라서, 투수부직포 재배조 표면 증발법이 가장 효율적인 배지냉각 방법이라고 판단된다.