• Title/Summary/Keyword: zinc galvanizing

Search Result 58, Processing Time 0.023 seconds

Charactristice of a colored Galvanized Coating using Ti-Zn Alloy System (Zn-Ti계용융아연 도금강판의 착색화 특성)

  • 전선호
    • Journal of the Korean institute of surface engineering
    • /
    • v.30 no.5
    • /
    • pp.320-332
    • /
    • 1997
  • The development of colored surface on zinc coating by the oxidation of a melten alloy of zinc with a minor amount of oxygen-avid additive such as tianium has been studied. Using a galvanizing Zinc alloy containing 0.1 to 0.3wt%Ti, gold, purple or blue color was developed clearly and stably, depending upon the extent of oxidation, by air cooling after hot dipping in a bath at temperature of $550^{\circ}C$ to $600^{\circ}C$. The source of the color is light interference with surface oxide layer. THe final color depends on the thickness of the color depends on the thickness of $TiO_2$, played So compositing, temperature and time at elevated temperature after are all controlling variables. Since oxidation film such as $TiO_2$ played role of passivation film, the corrosion resistance in a colored galvanized steel sheet. It is also thought that surface oxide layer of $TiO_2$ inhibited dissolution of the coating layer.

  • PDF

Effect of Nickel Addition in Hot Dip Galvanizing of Mini-mill Steels Containing Silicon (실리콘을 함유한 미니밀 소재의 용융아연도금성에 미치는 니켈첨가의 영향)

  • Lee, H.J.;Kim, J.S.;Chung, J.H.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.2
    • /
    • pp.157-164
    • /
    • 1999
  • In this study the effect of nickel addition on the coating weight of mini-mill steels containing silicon has been studied. It is shown that the pure zinc accelerated growth of the alloy layers occurred by a rapid growth of the zeta phase at 0.06%Si. The addition of 0.06%Ni to a pure zinc bath was found to be very effective in reducing the coating weight and promoting preferential development of the delta phase. The coating obtained by immersion in the Zn-Ni bath shows the presence of a nickel-rich region between the zeta phase and the eta phase. It is suggested that nickel prevents the rapid growth of the zeta phase due to the formation of the Zn-Ni-Fe ternary compound, which may act as a barrier to inward diffusion of zinc or iron at the zeta-eta boundary.

  • PDF

A Numerical Analysis on the Coating Thickness in Continuous Hot-Dip Galvanizing (연속 아연 도금 코-팅 두께에 관한 수치 해석적 연구)

  • Lee, Dong-Won;Shin, Seung-Young;Kim, Byung-Ji;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2955-2960
    • /
    • 2007
  • To control the coating thickness of zinc in the process of continuous hot-dip galvanizing, it is known from early day that the gas wiping through an air knife system is the most effective because of the obtainable of uniformity of coating thickness, possibility of thin coating, working ability in high speed and simplicity of control. But, the gas wiping using in the galvanizing process brings about a problem of splashing from the strip edge for a certain high speed of coating. And, it is known that the problem of splashing is caused mainly by the existence of separation bubble at the neighbor of the strip surface. In theses connections, in the present study, we proposed two kinds of air knife systems having the same expansion rate of nozzle, and the jet structures and coating thicknesses from a conventional and new proposed nozzles are compared. In numerical analysis, the governing equations consisted of two-dimensional time dependent Navier-Stokes equations, standard ${\kappa}-{\varepsilon}$ turbulence model to solve turbulence stress and so on are employed. As a result, it is found that it had better to use the constant rate nozzle from the point view of the energy saving to obtain the same coating thickness. Also, to reduce the size of separation bubble and to enhance the cutting ability at the strip, it is recommendable to use an air knife having the constant expansion rate nozzle.

  • PDF

Corrosion Mechanism and Bond-Strength Study on Galvanized Steel in Concrete Environment

  • Kouril, M.;Pokorny, P.;Stoulil, J.
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2017
  • Zinc coating on carbon steels give the higher corrosion resistance in chloride containing environments and in carbonated concrete. However, hydrogen evolution accompanies the corrosion of zinc in the initial activity in fresh concrete, which can lead to the formation of a porous structure at the reinforcement -concrete interface, which can potentially reduce the bond-strength of the reinforcement with concrete. The present study examines the mechanism of the corrosion of hot-dip galvanized steel in detail, as in the model pore solutions and real concrete. Calcium ion plays an important role in the corrosion mechanism, as it prevents the formation of passive layers on zinc at an elevated alkalinity. The corrosion rate of galvanized steel decreases in accordance with the exposure time; however, the reason for this is not the zinc transition into passivity, but the consumption of the less corrosion-resistant phases of hot-dip galvanizing in the concrete environment. The results on the electrochemical tests have been confirmed by the bond-strength test for the reinforcement of concrete and by evaluating the porosity of the cement adjacent to the reinforcement.

Study of Characteristics of Hot Dip Galvanized Steel Strip by Oxygen-free Finishing (비산화성 분위기에 의한 용융아연도금의 특성 연구)

  • 진영구;김흥윤
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.5
    • /
    • pp.300-308
    • /
    • 1995
  • The effect of nitrogen finishing for the control of coating weight in a nitrogen sealing box on the coating surface property in hot dip galvanizing process has been studied. The coated surface is free of oxide marks and edge overcoated. The coating uniformity is excellent ; the standard deviation of the coating thickness along width of the specimen was $1~1.2\mu\textrm{m}$ in the box whereas $2.5~3\mu\textrm{m}$ in the air. Considering surface quality of the coating such as oxide mark, edge overcoated and zinc dust, the oxygen content between 40 and 200 ppm was suggested in the box in addition the oxygen content of at least 40 ppm or the minimum dew point of $-27^{\circ}C$ is required to prevent a zinc vaporization.

  • PDF

A Study on Coating Adhesion of Hot Rolled Galvanized Iron Manufactured without pickling process (산세생략형 열연 용융아연도금강판의 특성)

  • 최진원;전선호
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.1
    • /
    • pp.21-30
    • /
    • 1999
  • Coating adherance behavior of low carbon steels, produced by POSCO, Korea, was studied in order to study the characteristics of hot rolled galvanized iron(HGI) manufactured without pickling line and the development of its process. Galvanizing experiments were carried out in zinc pot with 0.2wt% Al after hot rolled plates with scale were reduced at $550~750^{\circ}C$ in 10~30% hydrogen gas atmosphere during 60~400seconds. The reduced plates and coated products were examined by SST, XRD, SEM and EPMA on their surfaces and cross sections. Coating layer of HGI manufactured with pickling line was composed of retained scale, Fe-Zn-Al compound, Fe-Zn compound ($\delta_1\;and\;\zeta$ Phase) and pure zinc. It was superior to HGI in coating adhesion. It seems to be due to forming of Fe-Zn-Al compound in interface of matrix and retained porous scale.

  • PDF

Challenges in the Production of Thin Coatings at High Line Speed

  • Michel, Dubois;Luc, Warichet;Jose, Callegari
    • Corrosion Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Cost reduction of products is and will always be a key objective of industrials. However, it is well identified that the wiping process reaches its limits at high line speed in general and especially thin coatings. If wiping models predict that it is possible to reach 32-37 g/$m^2$ of pure Zinc at 180 m/min provided the nozzle to strip distance can be reduced to 6mm, the possibility to reach that process window industrially with sufficient robustness is debated. 3 key problems are reviewed and analyzed: Zinc splashing and liquid drop emissions of various forms, the production of skimming and the noise generated by the nozzles. The available data and models are firstly used to predict phenomena. Secondly, videos and pictures from the lines showing what really happens on the edges especially in case of a strip width change are analyzed. Whereas the predicted level of skimming to remove from the pot is expected very high, it turns out that the target may be very close to the full splashing phenomena and that the most critical industrial situation is related to strip specification changes. It is then expected that the industrial feasibility of the 32-37 g/$m^2$ at 180 m/min will depend strongly on the amount of incoming strip with the same width that can be processed continuously.

Measurement of Al Concentration in Liquid Zinc by E.M.F Method with $CaF_2$ ($CaF_2$ 기전력법에 의한 용융아연 중 알루미늄 농도의 측정)

  • Park Jin Sung;Kim Hang Soo;Jung Woo-Gwang;Katayama I.;Kim Jong Sang
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.204-210
    • /
    • 2000
  • The control of dissolved aluminum concentration in the hot dip zinc galvanizing bath is greatly important in producing galvannealed steel sheets. The purpose of present study is to provide basic data for measurement of the aluminum concentration in site in hot dip zinc bath at the temperature of $460^{\circ}C\~500^{\circ}C$ using $CaF_2$ solid electrolyte sensor with three kinds of reference electrode. Good workability and stability of the sensor were confirmed with the $Bi+BiF_3$ reference electrode from the emf measurement. In order to measure the aluminum concentration in Zn-Al bath, the galvanic cell of fluorine ion was constructed with $CaF_2$ solid electrolyte as follows; $$(-)W|Zn-Al,\;AlF_3|CaF_2|Bi,BiF_3|W(+)$$. The emf measurement was made at the temperature of $460\pm10^{\circ}C$ in the Zn-Al bath. The following correlationship between aluminum concentration and emf was obtained by the least square regression analysis; $$E/mV=56.795log[\%Al]+1881.7\;R=0.9704$$,$$0.026wt\%{\leq}[\%Al]{\leq}0.984wt\%$$

Numerical Simulation of an Impinging Jet with Various Nozzle-to-strip Distances in the Air-knife System

  • So, Hong-Yun;Yoon, Hyun-Gi;Chung, Myung-Kyoon
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.239-246
    • /
    • 2010
  • When galvanized steel strip is produced through a continuous hot-dip galvanizing process, the thickness of the adhered zinc film is controlled by impinging a thin plane nitrogen gas jet. The thickness of the zinc film is generally affected by impinging pressure distribution, its gradient and shearing stress at the steel strip. These factors are influenced by static pressure of gas spraying at air knife nozzle, a nozzle-to-strip distance and strip and a geometric shape of the air knife, as well. At industries, galvanized steel strip is produced by changing static pressure of gas and a distance between the air knife nozzle and strip based on experimental values but remaining a geometric shape of nozzle. Splashing and check-mark strain can generally occur when a distance between the air knife nozzle and strip is too short, while ability of zinc removal can lower due to pressure loss of impinging jet when a distance between the air knife nozzle and strip is too long. In present study, buckling of the jet and change of static pressure are observed by analyzing flow characteristics of the impinging jet. The distance from the nozzle exit to the strip varies from 6 mm to 16 mm by an increment of 2 mm. Moreover, final coating thickness with change of a distance between the air knife nozzle and strip is compared with each case. An ability of zinc removal with the various distances is predicted by numerically calculating the final coating thickness.

Improvement of Hot Dip Galvanizing Process by Additive to Flux Solution (플럭스액의 첨가제에 의한 용융아연도금 공정개선)

  • Moon, Kyung-Man;Jeong, Jae-Hyun;Park, Jun-Mu;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.6
    • /
    • pp.513-520
    • /
    • 2016
  • Many surface protection methods have been developed to apply to constructional steels which have been used under severe corrosive environments. One of these methods, hot dip galvanizing is being widely used to the numerous constructional steels such as a guard rail of high way, various types of structural steel for manufacturing ship and for some other industrial fields etc.. Recently, the cost of zinc is getting higher and higher, thus, it is considered that improvement of hot dip galvanizing process to reduce the cost of production should be developed possibly. In this study, additives such as acid cleaning solution, $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ were added to flux solution, and omission of water washing treatment after acid cleaning was investigated with some types of flux solutions added with some additives mentioned above. The decrement of pH by adding the acid cleaning solution could be controlled due to neutralization reaction with addition of $NH_4OH$. The flux solution added with both $NH_4OH$ and $Al(OH)_3$ exhibited nearly the same color and pH value as those of orignal flux solution with no added, and the sample dipped to the flux solution which was added with additives mentioned above indicated a relatively good corrosion resistance compared to other samples. However, the flux solution added with $NH_4OH$, $Al(OH)_3$ and $H_2O_2$ exhibited a different color, sediment and a bad corrosion resistance. Consequently, it is considered that omission of water washing treatment may be able to perform by adding optimum additives to the original flux solution.