• Title/Summary/Keyword: zero-loss

Search Result 526, Processing Time 0.039 seconds

Empirical Investigation on Information Breach Effect on the Market Value of the Firm: Focused on Source and Long Term Performance (정보유출이 기업가치에 미치는 효과분석: 원천 및 장기성과)

  • Kwon, Sun Man;Han, Chang Hee
    • The Journal of Society for e-Business Studies
    • /
    • v.21 no.2
    • /
    • pp.81-96
    • /
    • 2016
  • This paper analyzes the impact of information breach on shareholder value by measuring the stock price reaction associated with the announcements of data breach. The breach firms in the sample lost, on average, 1.3% of their market value, amounting to 98.9 million won of loss within two-day of the event period after the announcement. We examine the abnormal returns in various categories (i.e., source, type, size, etc.) of information breach. Although the market does not react significantly to the announcements of outside breach, we find statistically significant market reactions to inside breach. We estimate abnormal returns over the following 60 days. The mean 60-day cumulative abnormal return and BHAR (buy-and-hold abnormal returns) are both significantly far from zero. We conclude that there is a coherent market reaction following the announcement. The difference between the market reactions to IT firms and Non-IT firms is statistically significant. But breach amount, firm size, and the year the breach occurred do not show to be significant variables.

Critical Conduction Mode BOOST Type Solar Array Regulator (임계모드 부스트형 태양전력 조절기)

  • Yang, JeongHwan;Ryu, SangBurm;Yun, SeokTeak
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.86-90
    • /
    • 2014
  • A DC-DC Converter operates in CCM(Continuous Coundcution Mode), DCM(Discontinuous Conduction Mode), CRM(Critical Conduction Mode). The CRM is boundary between CCM and DCM. If a DC-DC converter is designed to operate in CRM, its inductor volume can decrease and power loss which caused by switch and diode can decrease. In this paper, the DC-DC converter which operates in CRM is applied to a solar array regulator(SAR) for the satellite. The switching frequency of the CRM boost SAR changes according to input and output condition. The switching frequency limit logic is applied to limit the maximum switching frequency. Meanwhile, the small signal transfer function of the CRM boost SAR is simple, so the controller design is also simple. In this paper, the small signal transfer function from control reference to solar array voltage is induced. And the voltage controller is designed based on the small signal transfer function. Finally, the CRM boost SAR is verified by simulation.

A Study on Partial Resonant AC-DC Chopper of Power Factor Correction (역률개선형 부분공진 AC-DC 초퍼에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • In this paper, author proposes a novel step-up AC-DC chopper operated with power factor correction(PFC) and with high efficiency. The proposed chopper behaves with discontinuous current control(DCC) of input current. The input current waveform in the proposed chopper is got to be a discontinuous sinusoid form in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC chopper, the switching devices are turned-on with the zero current switching, but turn-off of the switching devices is switched at current maximum value. To achieve a soft switching of the switching rum-off, the proposed chopper is used a new partial resonant circuit. The result is that the switching loss is very low and the efficiency of chopper is high.

  • PDF

Investigation of Transonic and Supersonic Flows over an Open Cavity Mounted on Curved Wall (I) - Steady Flow Characteristics - (곡면상에 설치된 열린 공동을 지나는 천음속/초음속 유동에 관한 연구 (I) - 정상 유동의 특성 -)

  • Ye, A Ran;Das, Rajarshi;Kim, Huey Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.231-236
    • /
    • 2015
  • Investigations into cavity flows have been conducted for decades now, most of them being about zero-pressure-gradient flows entering a cavity on a straight wall. However, the flow over curved walls in real-life situations has not been fully investigated. As cavity flows on curved walls exert centrifugal force, these walls are likely to possess different features from straight walls. To verify this possibility, this study investigated cavity flows on curved walls. Using numerical method, the effect of two variables, namely, radius of curvature on a curved wall and inlet Mach number, were investigated for subsonic and supersonic cavity flows. The result demonstrates that the value of the peak pressure generated inside the cavity increases with the decrease in the radius of curvature on a curved wall or an increase in the inlet Mach number. The total pressure loss in the cavity also results in an increase in the cavity drag.

A Novel Step-up AC-DC Converter with PFC by Discontinuous Current Control (전류불연속 제어에 의한 새로운 PFC 승압형 AC-DC 컨버터)

  • Kim, Choon-Sam;Shim, Jae-Sun;Kim, Chun-Sik;Lee, Hyun-Woo;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.142-148
    • /
    • 2006
  • In this paper, authors propose a novel step-up AC-DC converter operated with power factor correction (PFC) and with high efficiency. The proposed converter behaves with discontinuous current control (DCC) of input current. The input current waveform in the proposed converter is got to be a discontinuous sinusoid form in proportion to magnitude of at input voltage under the constant duty cycle switching. Therefore, the input power factor is nearly unity and the control method is simple. In the general DCC converters, the switching devices are turned-on with the zero current switching (ZCS). But turn-off of the switching devices is done at the maximum current. To achieve a soft switching at turn-off, the proposed converter uses a new partial resonant circuit, which results in the very low switching loss and the high efficiency of converter.

A effect of the back contact silicon solar cell with surface texturing size and density (표면 텍스쳐링 크기와 밀도가 후면 전극 실리콘 태양전지에 미치는 영향)

  • Jang, Wanggeun;Jang, Yunseok;Pak, Jungho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.112.1-112.1
    • /
    • 2011
  • The back contact solar cell (BCSC) has several advantages compared to the conventional solar cell since it can reduce grid shadowing loss and contact resistance between the electrode and the silicon substrate. This paper presents the effect of the surface texturing of the silicon BCSC by varying the texturing depth or the texturing gap in the commercially available simulation software, ATHENA and ATLAS of the company SILVACO. The texturing depth was varied from $5{\mu}m$ to $150{\mu}m$ and the texturing gap was varied from $1{\mu}m$ to $100{\mu}m$ in the simulation. The resulting efficiency of the silicon BCSC was evaluated depending on the texturing condition. The quantum efficiency and the I-V curve of the designed silicon BCSC was also obtained for the analysis since they are closely related with the solar cell efficiency. Other parameters of the simulated silicon BCSC are as follows. The substrate was an n-type silicon, which was doped with phosphorous at $6{\times}10^{15}cm^{-3}$, and its thickness was $180{\mu}m$, a typical thickness of commercial solar cell substrate thickness. The back surface field (BSF) was $1{\times}10^{20}\;cm^{-3}$ and the doping concentration of a boron doped emitter was $8.5{\times}10^{19}\;cm^{-3}$. The pitch of the silicon BCSC was $1250{\mu}m$ and the anti-reflection coating (ARC) SiN thickness was $0.079{\mu}m$. It was assumed that the texturing was anisotropic etching of crystalline silicon, resulting in texturing angle of 54.7 degrees. The best efficiency was 25.6264% when texturing depth was $50{\mu}m$ with zero texturing gap in case of low texturing depth (< $100{\mu}m$).

  • PDF

An application of LAPO: Optimal design of a stand alone hybrid system consisting of WTG/PV/diesel generator/battery

  • Shiva, Navid;Rahiminejad, Abolfazl;Nematollahi, Amin Foroughi;Vahidi, Behrooz
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.67-84
    • /
    • 2020
  • Given the recent surge of interest towards utilization of renewable distributed energy resources (DER), in particular in remote areas, this paper aims at designing an optimal hybrid system in order to supply loads of a village located in Esfarayen, North Khorasan, Iran. This paper illustrates the optimal design procedure of a standalone hybrid system which consists of Wind Turbine Generator (WTG), Photo Voltaic (PV), Diesel-generator, and Battery denoting as the Energy Storage System (ESS). The WTGs and PVs are considered as the main producers since the site's ambient conditions are suitable for such producers. Moreover, batteries are employed to smooth out the variable outputs of these renewable resources. To this end, whenever the available power generation is higher than the demanded amount, the excess energy will be stored in ESS to be injected into the system in the time of insufficient power generation. Since the standalone system is assumed to have no connection to the upstream network, it must be able to supply the loads without any load curtailment. In this regard, a Diesel-Generator can also be integrated to achieve zero loss of load. The optimal hybrid system design problem is a discrete optimization problem that is solved, here, by means of a recently-introduced meta-heuristic optimization algorithm known as Lightning Attachment Procedure Optimization (LAPO). The results are compared to those of some other methods and discussed in detail. The results also show that the total cost of the designed stand-alone system in 25 years is around 92M€ which is much less than the grid-connected system with the total cost of 205M€. In summary, the obtained simulation results demonstrate the effectiveness of the utilized optimization algorithm in finding the best results, and the designed hybrid system in serving the remote loads.

Corrosion mitigation of photovoltaic ribbon using a sacrificial anode (희생양극을 이용한 태양광 리본의 부식 저감)

  • Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.681-686
    • /
    • 2017
  • Degradation is commonly observed in field-aged PV modules due to corrosion of the photovoltaic ribbon. The reduced performance is caused by a loss of fill factor due to the high series resistance in the PV ribbon. This study aimed to mitigate the degradation by corrosion using five sacrificial anodes - Al, Zn and their alloys - to identify the most effective material to mitigate the corrosion of the PV ribbon. The corrosion behavior of the five sacrificial anode materials were examined by open circuit potential measurements, potentiodynamic polarization tests, and galvanic current density and potential measurements using a zero resistance ammeter. Immersion tests for 120 hours were also conducted using materials and damp heat test tests were performed for 1500 hours using 4 cell mini modules. The Al-3Mg and Al-3Zn-1Mg sacrificial anodes had a low corrosion rate and reduced drop in power, making then suitable for long-term use.

Evaluation of Direct Vessel Injection Design With Pressurized Thermal Shock Analysis (가압 열충격해석에 의한 직접용기주입 설계의 평가)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.86-97
    • /
    • 1992
  • The purpose of this paper is to evaluate the direct vessel injection design from a pressurized thermal shock(PTS) viewpoint for the Combustion Engineering System 80+ A break of the main steam line from zero power and a 0.05 ft$^2$small break loss-of-coolant accident (LOCA) from full power were selected as the potential PTS events. In order to investigate the stratification effects in the reactor downcomer region, the fluid mixing analysis was performed using the COMMIX-IB code for steam line break and using the REMIX code for 0.05 ft$^2$small break LOCA. The stress distributions within the reactor vessel walls experiencing the pressure and the temperature transients were calculated using the OCA-P code for both events. The results of the analysis showed that a small break LOCA without decay heat presented the greatest challenge to the vessel, however, there is no crack initiation through end-of-life of the vessel with consideration of decay heat.

  • PDF

Evaluation of the Flowability and Compressive Strength of Alkali-Activated Blast Slag Mortar (고로슬래그 알칼리 활성 모르타르의 유동성 및 압축강도 평가)

  • Ryu, Gum-Sung;Kang, Hyun-Jin;Koh, Kyung-Taek;Lee, Jang-Hwa;Kang, Su-Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.613-616
    • /
    • 2008
  • Many researches on alkali-activated concrete that does not need the presence of cement as a binder have been carried out recently. Instead, the source of material such as fly ash and blast slag, that are rich in Silicon(Si) and Aluminium(Al), are activated by alkaline liquids to produce the binder. Hence concrete with no cement is effect reduction of CO$_2$ gas. In this study, we investigated the influence of the workability and compressive strength of mortar on water reducing agent, alkaline activator and curing method in oder to develop cementless blast slag based alkali-activated mortar. In view of the results, we found out that the flowability of mortar was lowered as increasing to mole concentration of NaOH, but not large the loss of flowability to 9M NaOH, most of water reducing agent was not effect. The compressive strength was improved as increasing to mole concentration of NaOH, was the most effect in 9M NaOH. The curing temperature and curing conditions on compressive strength of blast slag based alkali-activated mortar didn't influence.

  • PDF