• Title/Summary/Keyword: zero-energy

Search Result 1,178, Processing Time 0.027 seconds

Calculation of Leakage Inductance of Integrated Magnetic Transformer with Separated Secondary Winding Used in ZVS PSFB Converter

  • Tian, Jiashen;Zhang, Yiming;Ren, Xiguo;Wang, Xuhong;Tao, Haijun
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.644-651
    • /
    • 2016
  • A novel zero voltage switching (ZVS) phase shift full bridge (PSFB) converter used in geophysical exploration is proposed in this paper. To extend the ZVS ranges and increase power density of the converter, external inductor acting as leakage inductance is applied and integrated into the integrated magnetic (IM) transformer with separated secondary winding. Moreover, the loss of ZVS PSFB converter is also decreased. Besides, the analysis and accurate prediction methodology of the leakage inductance of the IM transformer are proposed, which are based on magnetic energy and Lebedev. Finally, to verify the accuracy of analysis and methodology, the experimental and finite element analysis (FEA) results of IM transformer and 40 kW converter prototypes are given.

Analysis of Grounding Resistance for Zero Energy Town Floating PV System Using Underground Wiring (매설지선 방식을 적용한 에너지 자립마을용 수상 태양광 발전 시스템의 접지저항 분석)

  • Ko, Jae-Woo;Lim, Jong-Log;Kim, David K.;Cha, Hae-Lim;Kim, Si-Han;Lee, Chang-Koo;Ahn, Hyung-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.5
    • /
    • pp.303-306
    • /
    • 2016
  • Floating PV system is installed on the water such as artificial lake, reservoir, river for the purposes of zero energy town and/or large scale of PV station. There are electrical gains from cooling effect by water and reflection of water surface. Particularly, floating PV power station with high efficiency solar cell modules receives a lot of attention recently. Floating PV system is installed on the water, which means grounding method to the frame of solar cell and electrical box such as connector band and distribution panelboard should be applied in different way from grounding method of PV system on land. The grounding resistance should be 10[${\Omega}$] in case the voltage is over 400[V] in accordance with Korean Standard. The applicable parameters are the resistivity of water in various circumstances, depth of water, and length of electrode in order to meet 10[${\Omega}$] of grounding resistance. We calculated appropriate length of the electrode on the basis of theoretical equation of grounding resistance and analyzed the relation between each parameters through MATLAB simulation. This paper explains grounding system of floating PV power station and presents considerations on grounding design according to the resistivity of water.

An Orthogonal Approximate DCT for Fast Image Compression (고속 영상 압축을 위한 근사 이산 코사인 변환)

  • Kim, Seehyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2403-2408
    • /
    • 2015
  • For image data the discrete cosine transform (DCT) has comparable energy compaction capability to Karhunen-Loeve transform (KLT) which is optimal. Hence DCT has been widely accepted in various image and video compression standard such as JPEG, MPEG-2, and MPEG-4. Recently some approximate DCT's have been reported, which can be computed much faster than the original DCT because their coefficients are either zero or the power of 2. Although the level of energy compaction is slightly degraded, the approximate DCT's can be utilized in real time implementation of image or visual compression applications. In this paper, an approximate 8-point DCT which contains 17 non-zero power-of-2 coefficients and high energy compaction capability comparable to DCT is proposed. Transform coding experiments with several images show that the proposed transform outperforms the published works.

A Novel Induction Heating Type Super Heated Vapor Steamer using Dual Mode Phase Shifted PWM Soft Switching High Frequency Inverter

  • Sugimura, Hisayuki;Eid, Ahmad;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.774-777
    • /
    • 2005
  • In this paper, a constant frequency phase shifting PWM controlled voltage source full bridge-type series load resonant high-frequency inverter using the IGBT power modules is presented for innovative consumer electromagnetic induction heating applications such as a hot water producer, steamer and super heated steamer. The full bridge arm side link passive quasi-resonant capacitor snubbers in parallel with the each power semiconductor device and high frequency AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is discussed and evaluated on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency soft switching PWM inverter topology, what is called class DE type. including the variable-power variable-frequency(VPVF) regulation function can expand zero voltage soft switching commutation range even under low output power setting ranges, which is more suitable and acceptable for induction heated dual packs fluid heater developed newly for consumer power utilizations. Furthermore, even in the lower output power regulation mode of this high-frequency load resonant tank high frequency inverter circuit it is verified that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

  • PDF

Theoretical Study for Structures and Spectroscopic Properties of C60(CH2)nOH (n=0~2) and C60(OH)2 (C60(CH2)nOH (n=0~2)와 C60(OH)2의 분자구조 및 분광학적 성질에 관한 이론 연구)

  • Lee, Ju-Young;Kim, Seung-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.6
    • /
    • pp.905-911
    • /
    • 2011
  • The possible minimum structures of $C_{60}(CH_2)_nOH$ (n=0~2) and $C_{60}(OH)_2$have been optimized using density functional theory (DFT) with the 6-311G (d,f) basis set. The harmonic vibrational frequencies and IR intensities are also determined to confirm that all the optimized geometries are true minima. Also zero-point vibrational energies (ZPVE) have been considered to predict the binding energies. The predicted binding energy of $C_{60}CH_2OH$ is about 10 kcal/mol more stable than the binding energy of $C_{60}OH$.

A Novel Epsilon Near Zero Tunneling Circuit Using Double-Ridge Rectangular Waveguide

  • Kim, Byung-Mun;Son, Hyeok-Woo;Hong, Jae-Pyo;Cho, Young-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.1
    • /
    • pp.36-42
    • /
    • 2014
  • In this paper, an epsilon near zero (ENZ) tunneling circuit using a double-ridge rectangular waveguide (RWG) is proposed for the miniaturization of a waveguide component. The proposed ENZ channel and is located in the middle of the input-output RWG (IORWG). The ratio of the height to the width of the channel waveguide is very small compared to the IORWG. By properly adjusting the ridge dimensions, the tunneling frequency of the proposed ENZ channel can be lowered to near the cut-off frequency of the IORWG. For the proposed ENZ tunneling circuit, the approach adopted for extracting the effective permittivity, effective permeability;normalized effective wave impedance, and propagation constant from the simulated scattering parameters was explained. The extracted parameters verified that the proposed channel is an ENZ channel and electromagnetic energy is tunneling through the channel. Simulation and measurement results of the fabricated ENZ channel structure agreed.

Instantaneous Power Compensation Theory in Three-phase Four-wire Systems (3상 4선 계통에서의 순시전력 보상이론)

  • Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.172-183
    • /
    • 2006
  • This paper analyzes instantaneous power compensation theory through comparing p-q theory and cross-vector theory which were proposed by Akagi and Nabae respectively in three-phase four-wire systems. The two compensation theories are identical when there is no zero-sequence voltage component in three-phase three-wire systems, However, when the zero-sequence voltage and/or current components exist in three-phase four-wire systems, the two compensation theories we different in definition on instantaneous real power and instantaneous imaginary power. Based on the analysis, this paper presents instantaneous power compensation method that can eliminate neutral current completely without using energy storage element when the zero-sequence current and voltage components exist in three-phase four-wire systems.

A Two-Phase Interleaved Bidirectional DC-DC Converter with Zero-Voltage-Transition (영 전압 천이를 갖는 2상 인터리브드 양방향 DC-DC 컨버터)

  • Lim, Chang-Soon;Ku, Nam-Joon;Kim, Min-Sub;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.431-439
    • /
    • 2014
  • The two-phase interleaved bidirectional DC-DC converter (TIBDC) is a very attractive solution to problems related to battery energy storage systems. However, the hard-switching TIBDC increases the switching loss and electromagnetic interference noise when the switching frequency increases. Hence, a soft-switching technique is required to overcome these disadvantages. In this study, a novel TIBDC with zero-voltage transition (TIBDC-ZVT) is proposed. Soft switching in the boost and buck main switches is achieved through a resonant cell that consists of a single resonant inductor and four auxiliary switches. Given its single resonant inductor, the proposed TIBDC-ZVT has a reduced size and can easily be implemented. The validity of the proposed TIBDC-ZVT is verified through experimental results.

A Novel Zero-Voltage-Switching Push-Pull Forward Converter with a Parallel Resonant Network

  • Cai, Chunwei;Shi, Chunyu;Guo, Yuxing;Yang, Zi;Meng, Fangang
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.20-30
    • /
    • 2017
  • A novel zero-voltage-switching (ZVS) push-pull forward converter with a parallel resonant network is presented in this paper. The novel topology can provide a releasing loop for the energy storage in a leakage inductor for the duration of the power switching by the resonant capacitors paralleled with the primary windings of the transformer. Then the transformer leakage inductor is utilized to be resonant with the parallel capacitor, and the ZVS operation is achieved. This converter exhibits many advantages such as lower duty-cycle losses, limited peak voltage across the rectifier diodes and a higher efficiency. Furthermore, the operating principles and key problems of the converter design are analyzed in detail, and the ZVS conditions are derived. A 500W experimental converter prototype has been built to verify the effectiveness of the proposed converter, and its maximum efficiency reaches 94.8%.

Bi-Directional Interleaved Current-Fed Resonant Converter with Reduced Sized of Output Filter for FCEV (출력 필터의 크기를 줄인 연료전지 자동차용 양방향 인터리브드 전류원 공진형 컨버터)

  • Moon, Dong-Ok;Park, Jun-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.503-510
    • /
    • 2014
  • This study proposes a bi-directional interleaved current-fed resonant converter (CRC) with reduced size of the output filter for a fuel cell electric vehicle. The proposed CRC achieves zero-current switching turn on and off of switches and diodes and makes ripple current of the output capacitor theoretically zero. As a result, the cost and volume of the output capacitor are significantly reduced. The two-stage power conversion technique is also applied for wide input and output voltage range operations. A 2kW prototype of the proposed converter is built and tested to verify the validity of the proposed operation.