• 제목/요약/키워드: zero energy building

검색결과 138건 처리시간 0.023초

Sustainable Smart City Building-energy Management Based on Reinforcement Learning and Sales of ESS Power

  • Dae-Kug Lee;Seok-Ho Yoon;Jae-Hyeok Kwak;Choong-Ho Cho;Dong-Hoon Lee
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권4호
    • /
    • pp.1123-1146
    • /
    • 2023
  • In South Korea, there have been many studies on efficient building-energy management using renewable energy facilities in single zero-energy houses or buildings. However, such management was limited due to spatial and economic problems. To realize a smart zero-energy city, studying efficient energy integration for the entire city, not just for a single house or building, is necessary. Therefore, this study was conducted in the eco-friendly energy town of Chungbuk Innovation City. Chungbuk successfully realized energy independence by converging new and renewable energy facilities for the first time in South Korea. This study analyzes energy data collected from public buildings in that town every minute for a year. We propose a smart city building-energy management model based on the results that combine various renewable energy sources with grid power. Supervised learning can determine when it is best to sell surplus electricity, or unsupervised learning can be used if there is a particular pattern or rule for energy use. However, it is more appropriate to use reinforcement learning to maximize rewards in an environment with numerous variables that change every moment. Therefore, we propose a power distribution algorithm based on reinforcement learning that considers the sales of Energy Storage System power from surplus renewable energy. Finally, we confirm through economic analysis that a 10% saving is possible from this efficiency.

공사비 변화에 따른 제로에너지건축물 경제성 분석 - 사회적비용을 고려한 비용편익 분석을 중심으로 - (Economic Analysis of Zero Energy Building in South Korea - focusing on Cost-Benefit analysis considering Social Cost -)

  • 김재문
    • 대한건축학회논문집:구조계
    • /
    • 제36권3호
    • /
    • pp.147-157
    • /
    • 2020
  • With the increasing obligation to reduce greenhouse gas emissions to the building sector, the government has been gradually expanding its obligation to zero-energy buildings since 2020. Since the ZEB certification took effect in 2017, 48 preliminary and main certifications have been completed as of March 2019, and most of them are public buildings or even certified, but have earned Grade 5 of ZEB. This means that compared with the number of annual building permits registered in Korea, the figure is insignificant, and that it receives little if not mandatory. Therefore, this study investigated empirical cases of ZEB additional construction cost and conducted cost benefit analysis according to changes in ZEB additional construction cost based on a preliminary feasibility analysis project recently conducted by the KDI. In addition, considering the public buildings, the social costs were considered, and the cost-benefit analysis method was the same as the KDI's preliminary feasibility analysis method. The analysis shows that if the ratio of ZEB additional construction cost is more than 5 percent, it is analyzed that there is no economic feasibility, and considering that the ratio of additional construction cost in the cases of ZEB in Korea is 17 percent to 38 percent, it will not be easy to obtain ZEB certification in terms of cost. Finally, to narrow these differences in cost and economic aspects, the overseas low energy and ZEB incentive examples proposed measures such as the concept of subsidy payment in Illinois and the compensation of social costs to private ZEB.

창호의 광학적 특성에 따른 ZeSH의 일사취득 및 난방부하에 관한 민감도 분석 (A Sensitivity Analysis about Solar Heat Gain and Heating Load of ZeSH According to Optical Characteristics of Window system)

  • 손선우;백남춘;서승직
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.66-71
    • /
    • 2009
  • To reduce the building energy consumption, the major advanced nations are conducting actively many researches on so called a "self-sufficient building(or other words zero energy building)" which can support its required energy by itself. Given this background, KIER(Korea Institute of Energy Research) built full size test-bed of the zero energy solar house in early 2002, and has studied on the self-sufficient heating load up to now. We analyse the sensitivity between the heating load and the solar radiation gain according to the change the effective transmittance of windows. The authors classified 9 cases by solar transmittance of glass. The results demonstrate the solar radiation amount is 0.466 MWh from the eastern zone of Fl.,1(the first floor), 0.332 MWh from Fl.,2(the second floor), 1.194 MWh form the southern zone of F1., and 0.822 MWh from the southern zone of Fl.,2 on the case 1(each cases are classified by window types). On the case 9, the solar radiation amount is 3.127 MWh, 2.662 MWh, 8.799 MWh and 6.078 MWh from the same condition. For the Fl.,1, the amount of Heat Load that is saved per year ranged 10.5 to 48 %, and the reduction was anywhere from 0.2 to 17.9% for Fl.,2

  • PDF

시각적 쾌적성을 고려한 차양장치의 조명에너지 성능 분석 방법에 관한 연구 (A Study on the Lighting Energy Performance Analysis of a Shading Device based on Visual Comfort)

  • 오민석;이주윤;김기철
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.1-14
    • /
    • 2018
  • The shading device on the window of the building can be an passive solution to reduce the cooling load and lighting energy, as well as improving the indoor comfort. It is also an architectural element that must be considered for building energy-efficient buildings such as eco-buildings and zero-energy buildings. However, due to various building environments and various shading devices, the installation of excessive shade may lead to the risk of losing the effectiveness of windows. In this study, we propose a method for optimal automatic control of shading device and evaluate its effectiveness by energy analysis of several shading devices.

제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구 (Energy Saving by Combination of Element Technologies of Zero-Energy House)

  • 신현철;장건익
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

제로 에너지 건축물을 위한 자립형 저전력 IoT 센서 모듈 개발에 대한 연구 (A Study on Development of Independent Low Power IoT Sensor Module for Zero Energy Buildings)

  • 강자윤;조영찬;김희준
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권3호
    • /
    • pp.273-281
    • /
    • 2019
  • 국가 총에너지 소비량 중 건축물에서 소비하는 에너지는 전체의 10% 이상을 차지고 있다. 이러한 이유로 우리나라는 2025년부터 제로에너지 건물 의무화 정책을 채택하였고, 결국 건축물 에너지 절감 기술에 대한 연구가 요구되고 있다. 건축물 중 빌딩의 에너지 소비 형태를 분석해보면 조명 및 냉난방 에너지가 전체 에너지 소비량의 60% 이상을 차지하고 있는데, 이는 태양광 취득률 및 창문의 개폐 운용과 직접적인 연관이 있다. 본 논문에서는 건축물에너지 관리시스템에 취득 정보를 전송하기 위한 창호용 저전력 IoT 센서 모듈을 개발하기 위해 연구를 진행하였다. 이 모듈은 외부 환경 및 창문 개폐 상태 정보를 실시간으로 빌딩 에너지 관리 시스템에 전송하여 능동적으로 에너지 절감 조치를 취할 수 있게 네트워크를 구성하였다. 모듈에 사용되는 전력은 하베스트 에너지 중 태양광 발전을 이용한 독립적인 전원으로 설계하였다. 전원은 Buck 컨버터를 적용하여 MPPT 제어를 통해 리튬이온 배터리에 4V로 충전하는 방식으로 효율은 약 85.87%이다. 통신은 WiFi 방식을 적용하여 실시간으로 전송할 수 있도록 구성하였다. 모듈의 소비전력 저감을 위해 하드웨어 및 소프트웨어 측면에서 분석하여 저전력 IoT 센서 모듈을 구현에 대한 연구를 진행하였다.

지열 열펌프 및 태양광 발전 적용이 비주거용 건물의 에너지효율등급과 ZEB 인증 등급에 미치는 영향 (The Effect of a Geothermal Heat Pump and Photovoltaics Application on the Building Energy Efficiency and ZEB Certification Rating for a Non-Residential Building)

  • 문건호;박창용
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-13
    • /
    • 2023
  • Many government in the world have conducted building energy performance certification program to reduce building energy consumption. In this study, a reference building and its HVAC system was modeled, and the energy load and consumption were estimated by the ECO2 program. The software is a simple building energy simulation program based on monthly calculated method. The building energy efficiency rating the the reference building was 1+ under baseline condition. The simulation results showed that the insulation performance slightly affected building energy load and consumption, but light density had a significant effect on them. The application of geothermal heat pumps gave improvement of building energy efficiency rating but it could not make it possible to get zero energy building(ZEB) certification. The ZEB 5 certification could be achieved by using photovoltaics, however getting better grade was difficult. The simulation results showed that the ZEB 4 certification, one grade higher than ZEB 5, could be attained by using more than one renewable energy source such as geothermal and solar energy in this study.

벤투리 효과를 활용한 도심형 건물용 하이브리드 풍력 및 태양광 발전 시스템 기초타당성 예비연구 (Preliminary Feasibility Study on Wind and Solar Hybrid Power Systems based on Venturi Effects for Buildings)

  • 김수현;김윤수;박수민;안지현;이상훈
    • 신재생에너지
    • /
    • 제19권1호
    • /
    • pp.22-30
    • /
    • 2023
  • Recently, the use of renewable energy has been increasing to achieve carbon neutrality. The concept of a zero-energy building is also attracting attention. In this study, a preliminary study was conducted to analyze the feasibility of a hybrid wind and solar power generation system between buildings that utilize the building wind generated by the Venturi effect. For this purpose, the wind speed and sunshine hours were monitored in the area where the building wind blows by the Venturi effect, and the power generation depending on system types, areas, and season was estimated. Consequently, the wind power generation system showed a larger amount of power per area than solar power. The wind power systems can generate larger power if wind power blades are installed along the height of the building. As a preliminary study, this study verified the feasibility of the system utilizing building wind and suggested follow-up studies.

Identification of progressive collapse pushover based on a kinetic energy criterion

  • Menchel, K.;Massart, T.J.;Bouillard, Ph.
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.427-447
    • /
    • 2011
  • The progressive collapse phenomenon is generally regarded as dynamic. Due to the impracticality of nonlinear dynamic computations for practitioners, an interest arises for the development of equivalent static pushover procedures. The present paper proposes a methodology to identify such a procedure for sudden column removals, using energetic evaluations to determine the pushover loads to apply. In a dynamic context, equality between the cumulated external and internal works indicates a vanishing kinetic energy. If such a state is reached, the structure is sometimes assumed able to withstand the column removal. Approximations of these works can be estimated using a static computation, leading to an estimate of the displacements at the zero kinetic energy configuration. In comparison with other available procedures based on such criteria, the present contribution identifies loading patterns to associate with the zero-kinetic energy criterion to avoid a single-degree-of-freedom idealisation. A parametric study over a family of regular steel structures of varying sizes uses non-linear dynamic computations to assess the proposed pushover loading pattern for the cases of central and lateral ground floor column failure. The identified quasi-static loading schemes are shown to allow detecting nearly all dynamically detected plastic hinges, so that the various beams are provided with sufficient resistance during the design process. A proper accuracy is obtained for the plastic rotations of the most plastified hinges almost independently of the design parameters (loads, geometry, robustness), indicating that the methodology could be extended to provide estimates of the required ductility for the beams, columns, and beam-column connections.