• 제목/요약/키워드: zero current detection

검색결과 64건 처리시간 0.022초

Ungrounded System Fault Section Detection Method by Comparison of Phase Angle of Zero-Sequence Current

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.484-490
    • /
    • 2008
  • In this paper, an integrated fault section detection and isolation strategy is proposed based on the application of the Distribution Automation System(DAS) utilizing advanced IT and communication technologies. The Feeder Remote Terminal Unit(FRTU) has been widely used to collect data in the Korean distribution system. The achieved data is adopted in this method for detecting multiple fault types. Especially in the case of single phase-to-ground fault, the fault section is detected by comparison of the zero-sequence current phase angle. The test results have verified the effectiveness of the proposed method in a radial distribution system through extensive simulations in Matlab/Simulink. Furthermore, a communication-based demo system identical to the simulation model has been developed, and it can be applied as an online monitoring and control program for fault section detection and isolation.

전기설비의 저항성 누설전류 검출 및 특성 해석에 관한 연구 (Study on the Resistivity Leakage Current Detection and Properties Analysis of Electrical Installat ion)

  • 최충석;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.301-304
    • /
    • 2008
  • In this paper, we study from of flowing leakage current in electrical installation. Leakage current is expressed by a resistivity leakage current($I_{gr}$), a capacitive leakage current($I_{gc}$), an inductivity leakage current($I_{gl}$). General Zero Phase Current Transformer (ZCT) detect a leakage current($I_{g}$) that are conjoined resistivity leakage current and capacitive leakage current. In case $I_{gr}$ is big than $I_{gc}$, there is no singular problem in leakage current detection of system. But, in case $I_{gc}$ is big than $I_{gr}$, earth leakage breaker can not prevent accident effectively. Can lower electric leakage perception current to 5 mA if apply resistivity leakage current detecting circuit. We can achieve prevention of electricity disaster spontaneously.

  • PDF

이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구 (The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

영상변류기 동작 방식을 이용한 2개의 컨버터 병렬 운전시 고장 탐지 및 분리 (Fault Detection and Isolation of Parallel Operation of Two Converters Using Zero Current Transformer Method)

  • 손승찬;성세진
    • 전력전자학회논문지
    • /
    • 제5권4호
    • /
    • pp.409-416
    • /
    • 2000
  • 시스템 특성상 fault tolerant system을 위해 두개의 컨버티를 1개의 전류센서를 사용하여 영상변류기 동적 방식으토 병렬 운전하는 경우 컨버터에 고자이 발생하면 영상변류기 출력은 두 컨버터 공급 전류 차이이므로, 어떤 컨버터에서 고장이 발생하였는지 고정 탐지 및 분리가 곤란히였다. 본 논문에사는 fault tolerant system를 위해 2 개의 컨버터를 병렬 운전하는 경우 캔버터의 고장 탐지 및 분리를 위한 방안올 제시하고 실험을 통하여 제안한 방법의 타당성을 확인하였다.

  • PDF

Thyristor Switch를 사용한 무효전류 보상에 관한 연구 (A Study on Reactive Current Compensation Using Thyristor Switch)

  • 박민호;이복용
    • 전기의세계
    • /
    • 제28권12호
    • /
    • pp.41-45
    • /
    • 1979
  • Improvement of power factor is achieved by reactive-current compensation, connecting power condenser to the circuit. This paper describes a method of reactive-current compensation, employing thyristor switching of capacitor banks without any breaker. This method reduces supply transients to the minimum by means of connecting condenser, because thyristor is triggered at zero point in condenser current. The reactive current detection and the experimental system to trigger thyristor at appropriate moment are given. IThe results show the fast reactive-current compensation on the condition of minimum transient.

  • PDF

사람 행동 인식에서 반복 감소를 위한 저수준 사람 행동 변화 감지 방법 (Detection of Low-Level Human Action Change for Reducing Repetitive Tasks in Human Action Recognition)

  • 노요환;김민정;이도훈
    • 한국멀티미디어학회논문지
    • /
    • 제22권4호
    • /
    • pp.432-442
    • /
    • 2019
  • Most current human action recognition methods based on deep learning methods. It is required, however, a very high computational cost. In this paper, we propose an action change detection method to reduce repetitive human action recognition tasks. In reality, simple actions are often repeated and it is time consuming process to apply high cost action recognition methods on repeated actions. The proposed method decides whether action has changed. The action recognition is executed only when it has detected action change. The action change detection process is as follows. First, extract the number of non-zero pixel from motion history image and generate one-dimensional time-series data. Second, detecting action change by comparison of difference between current time trend and local extremum of time-series data and threshold. Experiments on the proposed method achieved 89% balanced accuracy on action change data and 61% reduced action recognition repetition.

단상 영구자석 동기 전동기의 비대칭 공극 구조를 고려한 회전자 초기 자극 검출 기법 (Rotor Initial Polarity Detection Method of Single-Phase PMSM Considering Asymmetric Air-Gap Structure)

  • 서승우;황선환;박종원;김용휴
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.80-83
    • /
    • 2022
  • This paper proposes an initial rotor polarity detection algorithm of a single-phase permanent magnet synchronous motor (SP-PMSM) related to stable open-loop starting for sensorless operation. Generally, the SP-PMSM needs an asymmetric air-gap structure to can avoid the initial starting failure at zero torque point. Therefore, the rotor polarity information can be obtained by using the DC offset current direction of a stator current through a high frequency voltage injection into an SP-PMSM with an asymmetric air gap. In this paper, the proposed rotor initial polarity detection algorithm is verified through several experimental results.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

영구자석형 동기발전기의 회전자 위치검출 센서의 옵셋 검출에 관한 연구 (A Study on a Rotor Position Sensor Offset Detection Method in a Permanent Magnet Synchronous Generator)

  • 박규성;신성환;이호광;윤영득;이근호
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.914-921
    • /
    • 2014
  • In this paper, an algorithm is suggested to detect an offset angle of the absolute rotor position sensor after the initial assembly of a PMSG. Unlike previous studies in a stationary state, this one is not designed to detect an electrical angle but rather the absolute position of the rotor is detected while operating the generator. Also,a position sensor, current sensors and voltage sensor were used to ensure reliability. This technique completes the detection of the sensor offset in two steps. In the first step, a zero-crossing of the EMF is measured using a voltage sensor to detect the electrical angle offset when the alternator is actuated by the engine. In the second step, a high frequency current is injected along the d-axis on-line during the control of the generation, eventually to obtain the inductance using a DFT (Discrete Fourier Transform), and then to ultimately extract the final electrical angle offset through the comparison of the inductance magnitude. The suggested algorithm was validated with PSIM simulation and, furthermore, was tested with actual experiments on a dynamometer.

EPD 신호검출에 의한 플라즈마식각공정의 이상검출 (Malfunction detection in plasma etching process using EPD signal trace)

  • 이종민;차상엽;최순혁;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1360-1363
    • /
    • 1996
  • EPD(End Point Detection) is used to decide etching degree of layer which must be removed at wafer etching process in plasma etching process which is one of the most important process in semiconductor manufacturing. In this thesis, the method which detects malfunction of etching process in real-time will be discussed. Several EPD signal traces are collected in normal plasma etching condition and used as reference EPD signal traces. Critical points can be detected by applying differentiation and zero-crossing techniques to reference EPD signal. Mean and standard deviation of critical parameters which is memorized from reference EPD signal are calculated and these determine the lower and higher limit of control chart. And by applying statical control chart to EPD signals which are collected in real etching process malfunctions of process are detected in real-time. By means of applying this method to the real etching process we prove our method can accurately detect the malfunction of etching process and can compensate disadvantage of current industrial method.

  • PDF