• Title/Summary/Keyword: xenon lamp

Search Result 112, Processing Time 0.029 seconds

Discharge characteristics of Flat Fluorescent Lamp (FFL(Flat Fluorescent Lamp)의 방전 특정)

  • Kwon, Soon-Seok;Ryu, Jang-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.44 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • This experiment was analysed the discharge characteristics of FFL(flat fluorescent lamp). FFL is operated by sine and pulse wave source. We use FFL which has the electrodes covered with dielectric, observed the discharge characteristics of FFL by V-Q Lissajous' figure. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. When the duty ratio increases, the number of metastable xenon atoms seem to increase. Consequently, the 172nm radiation becomes strong as the duty ratio increases.

Development of Excitation Light Source for Photodynamic Diagnosis of Cancer (광역학적 암진단을 위한 여기 광원장치의 개발)

  • Lim, Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.49-56
    • /
    • 2007
  • In this paper, the development of excitation light source is proposed for excitation light of the photodynamic therapy of cancer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosensitizer. This study aims at designing and evaluating light source that can stably generate light with various kinds of wavelengths in order to make possible photodynamic diagnosis using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source device by KFDA#s technical reference, the characteristics of the light output and wavelength band were found.

Reflector Design to Improve the Uniformity of an Irradiated Area Using a Xenon Flash Lamp (제논 플래시 램프 사용 시 조사 영역 균일도 개선을 위한 반사경 설계)

  • Kim, Seo-Young;Lee, Han-Yul;Jun, Won-Kyoun;Kang, Dong-Hwa;Jo, Ye-Ji;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.197-203
    • /
    • 2019
  • In this paper, we studied a reflector design that can improve the illuminance uniformity when using a xenon flash lamp in the photonic sintering process. To achieve complete sintering of substrates in the irradiated area, the light efficiency and illuminance uniformity were set to target performance. Existing elliptical reflectors or parabolic reflectors make it easy to satisfy the target light efficiency, but have difficulty satisfying the illuminance uniformity. In this paper, a twin-concave feature has been added to the center of the parabolic reflector to satisfy the illuminance uniformity. It was confirmed that the illuminance uniformity of the parabolic reflector with a twin-concave feature was improved, compared to that of the traditional reflector.

Fabrication and Property of Excimer Lamp Coated with Green-emitting Zn2SiO4:Mn2+ Phosphor Film (녹색발광 Zn2SiO4:Mn2+ 형광체가 코팅된 엑시머 램프의 제작 및 특성)

  • Kang, Busic;Jung, Hyunjee;Jeong, Yongseok;Son, Semo;Kim, Jongsu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.106-109
    • /
    • 2022
  • The green-emitting Zn2SiO4:Mn2+ phosphor film was evaluated in a xenon excimer lamp. The phosphor film with 2 ㎛ thick was formed of monolithic structure on the inner side of quartz through a long-time annealing process of coated ZnO solution doped with Mn2+ ion and SiO2 of quartz tube. The coated quartz was filled with 100 torr of xenon gas, and simultaneously both sides was melt and sealed. The xenon-field quartz tube was discharge by applying the voltage of 15 kV with a frequency of 26 kHz, and emitted the glow with dominant peak at 172 nm. The vacuum ultraviolet excited the inner-side coated Zn2SiO4:Mn2+ phosphor film, which emitted the pure and strong green light.

Fabrication of polymer tip on an optical fiber end-face by guided UV light (도파된 UV 빛에 의한 광섬유 단면의 폴리머 팁 제작)

  • Park, Min-Gyu;Jeong, Ho-Jung;O, Gyeong-Hwan
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.147-148
    • /
    • 2009
  • We have fabricated a down tapered polymer tip on optical fiber end-face by a guided UV light. One side of fiber was aligned with a mercury-xenon lamp and another was put into UV curable polymer. A shape of tip was controlled by adjusting an irradiance of lamp and time of exposure. A bending effect also affects the result. Optical characteristic was achieved preliminarily with solution of minute particles.

  • PDF

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

The study of optical properties by gas pressure and applied power in ICP Xe lamp (ICP 제논 램프의 가스 압력과 공급 전력에 따른 광학적 특성연구)

  • Choi, Gi-Seung;Lee, Jung-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.119-121
    • /
    • 2005
  • The problem of lamp life have being solved before electrode-less lamps were developed. But, mercury is using till now. So people are concerned about friendly-environmental lamp, and many researcher hardly study it. In this paper, an ICP lamp which is using Xe gas and Ne gas was designed after optical properties were measured and analyzed. As a result, H-mode properties and penning effect properties were known. Also xenon and neon of properties analyze by spectrum.

  • PDF

Laser absorption spectroscopy of ternary gas mixture of He-Ne-Xe in External Electrode Fluorescent Lamp (EEFL) (레이저 흡수 분광법을 이용한 He-Ne-Xe 상종가스의 외부전곡 램프의 $1s_4$ 공명준위와 $1s_5$ 준안정준위의 제논 원자 밀도에 대한 연구)

  • Jeong, S.H.;Oh, P.Y.;Lee, J.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.576-580
    • /
    • 2006
  • Mercury-free lamp, external electrode fluorescent lamp (EEFL) which includes the xenon gas, is now going on the research for the replacement of mercury lamp. The densities of excited xenon atom in the $1s_4$ resonance state and the $1s_5$ metastable state are investigated in the EEFL by a laser absorption spectroscopy under various gas pressures. We have measured the absorption signals for both $1s_4$ resonance and the $1s_5$ metastable state in the EEFL by varying the discharge currents for a given pressure. This basic absorption characteristic is very important for improvement of the VUV luminous efficiency of the EEFL as well as plasma display panel.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.