• Title/Summary/Keyword: xenon lamp

Search Result 112, Processing Time 0.031 seconds

Design of a Simmer Circuit for Xenon Flash Lamp Driver Based on a LCC Converter (LCC 컨버터 기반의 제논 플래시 램프 구동장치를 위한 시머회로 설계)

  • Song, Seung-Ho;Cho, Chan-Gi;Park, Su-Mi;Park, Hyun-Il;Bae, Jung-Su;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.231-232
    • /
    • 2017
  • This paper describes the design and implementation of a 2.5kW (500V, 5A) simmer circuit that maintains the ionization of xenon gas inside the lamp. The design is based on a LCC resonant converter in continuous conduction mode (CCM) with above resonant frequency to take advantage of high power density from using parasitic elements such as the leakage inductance in a power transformer. In addition, since the converter has current source output characteristics, it is suitable for maintaining ionization of the lamp having the negative resistance load characteristic. To verify this converter design, PSpice modeling was performed. Finally, the developed simmer circuit is verified by a resistive load of rated performance and the Ionization maintenance operation of the xenon flash lamp.

  • PDF

Discharge characteristics of FFL as applied voltage variation (인가 전압의 변화에 따른 FFL(Flat Fluorescent Lamp)의 방전특성)

  • 윤성현;박철현;조민정;임민수;권순석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.379-382
    • /
    • 2000
  • The characteristics of Xe discharge lamp(Mercuryless lamp) are described in this paper. In this paper, FFL is operated by sine wave and pulsed source. We apply V-Q Lissajous' figure for the discharge measurements of FFL which has the electrodes covered with dielectric. When FFL is operated by sine wave source, the characteristics are similar to DBD(Dielectric Barrier Discharge) and SD(Silent Discharge). And we compared the characteristics of FFL which is operated with sine wave and pulsed discharge by using V-Q Lissajous' figure method. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. As the duty ratio increases the electric field becomes strong and much more xenon ions are produced. And the number of metastable xenon atoms seem to increase, therefore, the phosphor radiation after the cut off of voltage increases compared with the first peak of radiation. Consequently, the 172㎚ radiation becomes strong as the duty ratio increases.

  • PDF

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

Effects of the Xe content on the electro-optical properties in the mercury-free Flat Fluorescent Lamp

  • Chung, Kyu-Yong;Lee, Sang-Mok;Jeong, Yoon-Chul;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1577-1579
    • /
    • 2007
  • Xe content is one of important factors related to characteristics of the mercury-free flat fluorescent lamp. The electro-optical properties of lamp were investigated for wide range of Xe content in Xe-Ne mixing gas. The maximum luminance of $9,289\;cd/m^2$ and efficacy of 3 lm/W was obtained with Xe 90 %.

  • PDF

Xe-free 8" class flat fluorescent lamp with good uniformity (8"평판형광램프에 관한 연구)

  • Park, S.G.;Kim, S.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.568-569
    • /
    • 2000
  • By manufacturing 8" class $146{\times}96mm$ "flat fluorescent lamp" of new form that uses xenon gas, an electric optical characteristic has been analyzed. Lamp shows that the lamp surface brightness is 4900 cd/m2 and the birghtness uniformity degree is 90% under sine wave of 15khz and applied voltage of 1,000 Vrms.

  • PDF

A New Xenon Plasma Flat Fluorescent Lamp Enhanced with MgO Nano-Crystals for Liquid Crystal Display Applications

  • Lee, Yang-Kyu;Heo, Seung-Taek;Lee, You-Kook;Lee, Dong-Gu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.4
    • /
    • pp.186-189
    • /
    • 2010
  • Nano-sized MgO single crystal powders have recently been reported to emit ultraviolet by stimulation of electrons in a vacuum. In this study, nanocrystalline MgO powders were applied to a xenon plasma flat fluorescent lamp (FFL) for a liquid crystal display backlight to improve its emission efficiency through the extra ultraviolet from the nano-MgO crystals. For comparison, a MgO nano-thin film was applied directly on the phosphors inside a lamp panel through e-beam evaporation. Adding MgO nano-crystal powders to the phosphors improved the luminance and efficiency of FFLs by around 20% and MgO nano-crystal coverage of 40% of the phosphor provided the best FFL emission characteristics; however, application of MgO thin film to the phosphors degraded the emission characteristics, even compared to FFLs without MgO. This was due to insufficient ultraviolet stimulation of the phosphors and the crystallinity and low secondary electron coefficient of the MgO.

The Power Supply System for Xenon Lamp Light Sintering (광소결용 제논 램프 구동을 위한 파워 서플라이 시스템)

  • Cho, Chan-Gi;Song, Seung-Ho;Park, Su-Mi;Park, Hyeon-Il;Bae, Jung-Soo;Jang, Sung-Roc;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.327-328
    • /
    • 2017
  • This paper presents the power supply system which is made of three units: the capacitor charging and main pulse unit, simmer power supply unit, and series trigger unit. The capacitor charging and main pulse unit charges the capacitor bank by using the series parallel resonant converter and the generated main pulses apply to the lamp. The series trigger unit ionize the xenon gas located in the lamp and the simmer power supply unit sustains the ionized condition. It means that the lamp lifetime and efficiency are advanced by reducing the number of triggering. Not only the operation of the proposed system but also the performance of each unit will be verified by the experimental results.

  • PDF

Analysis of Xenon Flash Lamp Discharge System for Laser Excitation (레이저 발진용 세논기체 섬광관의 방전계통해석)

  • 김영권;이문기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.25-30
    • /
    • 1968
  • The characteristics of single mesh discharge circiut for Xenon flashlamp has been analysised in detail. Since flashlamp voltage characteristics is linear in time, though nonlinear in current, the nonliear differential equation , for this system has beens solved by the analog computer. Also for given lamp type, energy input, pulse duration, and pulse shape factor, the inductance, capacatince and operating voltage were discussed.

  • PDF

Accelerated Weathering Behavior of XLPE (가교폴리에틸렌의 촉진 내후성)

  • Lee, Chul Ho;Kim, Sang Wook
    • Applied Chemistry for Engineering
    • /
    • v.5 no.4
    • /
    • pp.722-730
    • /
    • 1994
  • The effects of antioxidant and carbon black on weatherability of crosslinked polythylene(XLPE) for electrical insulation were investigated. 16 compositions were prepared in other to determine the weathering resistance. Samples were exposed in xenon-arc lamp Weather-Ometer for 500, 1000, 1500, 2000 hours respectively. Tensile strength, elongation at break, dielectric strength and tan ${\delta}$ were measured to evaluate the weatherability of XLPE. The results indicated that the effect of carbon black was more prominent than antioxidant and synergistic effect, was observed when two additives were mixed.

  • PDF

Improving Light Stability of Natural Rubber Latex Foam

  • Shim, Chang Su;Oh, Jeong Seok;Hong, Chang Kook
    • Elastomers and Composites
    • /
    • v.50 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • In this study, natural rubber latex foam was prepared in order to replace commercialized polyurethane foams as a car seat material. Physical properties of the latex foam were investigated and the light stability was improved. The latex foam was mixed in an aqueous solution state, and the degree of foaming and the accelerator ratios were appropriately controlled. Tensile properties, hysteresis and dynamic mechanical properties of the latex foam were measured to compare with those of polyurethane foams. UV light absorbers and radical scavengers were added for improving light stability of the latex foam. Xenon lamp test was conducted to investigate the effects of the reagents on light stability. Our results revealed that the prepared latex foam including a light absorber with an antioxidant showed excellent light stable performances.