• Title/Summary/Keyword: xenon

Search Result 282, Processing Time 0.031 seconds

Photovoltaic Properties in $CuPc/C_{60}$ heterojunction Structure ($CuPc/C_{60}$ 이종접합을 이용한 광기전 특성)

  • Kim, S.K.;Lee, H.D.;Huh, S.W.;Chung, D.H.;Oh, H.S.;Lee, W.J.;Lee, J.U.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.65-68
    • /
    • 2003
  • Recently, there is a growing concern on the photovoltaic effects using organic materials. This is a phenomena which converts the solar energy into the electrical one. We have fabricated a device structure of ITO/PEDOT:PSS/CuPc/$C_{60}$/BCP/Al. The PEDOT:PSS layer is made by spin coating. and the other organic layers are made by thermal vapor deposition. By measuring the current-voltage characteristics with an illumination of light. we have obtained a value of $V_{oc}$=0.358V and $J_{sc}$=0.338mA/$cm^2$. A fill factor and efficiency are about 0.271 and 0.033%, respectively. A 500W xenon lamp(ORIEL) was used for a light source, and the light intensity illuminated into the device was about 10mW.

  • PDF

녹색형광단백질로 구성된 분자광다이오드의 전자전달 특성

  • Nam, Yun-Seok;Choe, Jeong-U;Lee, Won-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.149-152
    • /
    • 2000
  • In recent years, various artificial molecular photodiode have been fabricated by mimicking the electron transport function of biological photosynthesis. And now, we have been investigated the protein-organic hetero thin film photodiode using GFP as an sensitizer based on the redox potential difference of functional molecules. In this paper, shows molecular photodiode consisting of green fluorescence protein(GFP). viologen and TCNQ. The TCNQ and viologen were deposited onto ITO coated glass by LB technique. And GFP molecule was adsorption onto the viologen LB film surface by self-assembly method. Finally, The Al deposition onto GFP/viologen/TCNQ film surface was performed to make a top electrode. As a result, The MIM(metal/Insulator/Metal) structured device was constructed. The input light of 460nm wavelength was generated by the xenon lamp system, and then the photocurrent produced from the molecular device was detected through a current-voltage(I-V) measuring unit (SMU Model 236, Keithley, USA). An artificial molecular photodiode using protein(GFP)-adsorbed hetero-LB film is presented as a model system for the bioelectronic device based on the biomimesis.

  • PDF

Crystal growth of langasite by floating zone method and characterization (bloating zone법을 이용한 Langasite 단결정 성장 및 특성 분석)

  • 김영석;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.2
    • /
    • pp.63-67
    • /
    • 2002
  • Langasite single crystal was grown by Xenon-arc floating zone method in mixutre of Af and $O_2$ gas atmosphere. Growing and rotation speed were 1.5 much and 15 rPm respectively. The grown crystal had a c-axis and color of orange. Composition of the grown crystal was $La_{3.10}Ga_{4.73}Si_{1.17}O_{14}$. Activation energy of the crystal was 0.23 eV and was PTC characteristics.

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

Study on the Ischemic penumbra concept in stroke patient by case study (허혈경계부의 감소를 보인 뇌졸중 환자에 대한 증례보고)

  • Ko, Seong-Gyu
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.341-348
    • /
    • 2000
  • I have treated one ischemic stroke patient in acute stage with Seonghyangjeonggi-san, and observed remarkable reduction of the size ischemic portion in brain CT, notable improved motor power of patient. So I report this case of stroke patint. The ischemic penumbra, simply stated, is the part of the brain that is sandwiched brain regions committed to die and those that receive enough blood to communicate. Therefore, it is ischemic brain tissue that has just enough to communicte and function. The life expectancy of the penumbrais short. Although the penumbra is an elegant concept, in practice, it has been a difficult one to exploit. Up to now, a lot of research worker have tried to develop the method to make a accurate diagnosis. and then we know that PET and Xenon CT is available for the diagnosis for the ischemic penumbra. But those are not perfect to diagnose of penumbra. The case in my case report was confirmed as ischemic penumbra with CT. I know that CT is not prefect to diagnose penumbra, but I just want to raise the interest in penumbra of oriental medicine researcher and my report will be benificial to the penumbra researcher.

  • PDF

The Fabrication of Microstructures and Curing Characteristics in Photopolymer on the Microstereolithography using a Dynamic Pattern Generator (다이내믹 패턴 형성기를 이용한 마이크로 광 조형기술에서 미세 구조물 제작 및 수지경화특성에 관한 연구)

  • Kwon B.H.;Choi J.W.;Ha Y.M.;Kim H.S.;Won M.H.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1181-1185
    • /
    • 2005
  • Microstereolithography has evolved from the stereolithography technique, and is also based on a light-induced layer-stacking manufacturing. Integral microstereolithography is proposed for building a 3D microstructure rapidly, which allows the manufacture of a complete layer by one irradiation only. In this study, we developed the integral microstereolithography apparatus based on the use of $DMD^{TM}$ as dynamic pattern generator. It is composed of Xenon-Mercury lamp, optical devices, pattern generator, precision stage, controllers and the control program. Also, we estimated curing characteristics in photopolymer. The relationship between the viscosity of diluent-oligomer solutions and curing width, irradiation time and curing property has been studied.

  • PDF

Titanium Oxide Film : A New Biomaterial For Artificial Heart Valve Prepared by Ion Beam Enhanced Deposition

  • Liu, Xianghuai;Zhang, Feng;Zheng, Zhihong;Huang, Nan
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.1-15
    • /
    • 1997
  • Titanium oxide films were prepared by ion beam enhanced deposition where the films were synthesized by deposition titianium atoms and simultaneously bombarding with xenon ion beam at an energy of 40 keV in an $O_2$ environ,ent. Structure and composition of titanium oxide films were investigated by X-ray Doffractopm (XRD) Ritjerfprd Backscattering Spectroscopy (RBS) and X-ray Diffraction(XRD) Rutherford Backscattering Spectroscopy (RBS) and X-ray photoelectron spectroscopy (XPS) The results show that thestructure of the prepared films exhibit a rutile phase structure wit high(200) orientation and the O/Ti ratio of the titanium oxide films was about 2:1 XPS anlysis shows that $Ti^{2+},Ti^{3+}\;and\;Ti^{4+}$ chemical states exist on the titanium oxide films. the blood compatibility of the titanium oxide films was studied by measurements of blood clotting time and platelet adhesion. The results show that the anticoagulation property of titanium oxide films improved significantly and better than that of LTI-carbon which was widely used to fabricate artificial heart valve.

  • PDF

Luminance Improvement by using New Sustain Pulse for AC PDP (새로운 유지 펄스를 이용한 AC PDP의 휘도 향상에 대한 연구)

  • Kim, Hyun-Seok;Lim, Jong-Sik;Kim, Joon-Yub
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.182-185
    • /
    • 2003
  • 본 논문은 AC PDP의 구조, 전극 및 가스등을 기존 방식 그대로 사용하면서 고휘도 방전모드를 구현할 수 있는 새로운 파형의 유지펄스에 관한 연구 결과이다. 기존 PDP 구조에서의 Plasma 방전은 음극영역에서 주된 방전이 발생하기 때문에 Xenon gas의 여기율이 낮아지게 됨으로 충분한 휘도를 얻을 수가 없었다. 이러한 PDP가 갖는 휘도 특성의 문제를 개선하기 위한 목적으로 Panel의 셀구조의 변형, 전극 구조의 변화 또는 방전 가스의 혼합비율조정 둥 다양한 노력과 시도를 계속하고 있다. 하지만 PDP의 생산 단가의 상승을 초래할 수 있으며, 전극 간격을 조절하여 휘도를 개선하는 방식은 화질의 저하시킬 뿐만 아니라 방전전압을 증가시키게 됨으로 소비전력을 증가시키게 된다. 본 연구에서 제안하는 새로운 방식의 유지방전 구동파형은 기존의 유지 방전 펄스인 스퀘어 펄스와는 다르게 계단형의 펄스를 사용하는 방식으로 방전이 일어나기 전까지 일정한 전압을 인가하여 유지시킨 뒤 어느 시점에서 방전 되기까지 전압을 올려주는 방법으로 PDP의 협소한 방전 영역을 증가 시킴으로써 고휘도를 얻을 수 있다. 실험 결과 기존의 유지펄스와 비교하여 39.4%의 휘도와 50.0%의 효율 향상을 얻을 수 있었다.

  • PDF

Light fastness of Zinc oxide for aramid fiber via sol-gel deposition (나노 산화아연 처리에 의한 파라 아라미드 섬유의 내광성 증진 연구)

  • Park, S.M.;Kim, M.S.;Kwon, I.J.;Sim, J.H.;Lee, K.N.;Yoon, N.S.
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2012.03a
    • /
    • pp.110-110
    • /
    • 2012
  • 아라미드 섬유소재는 고강도, 고내열성의 소재로 다양한 용도전개가 가능하나, 일광 및 부식에 의한 내광성 및 내후성이 급격하게 저하되는 단점이 있다. 자외선의 광화학적 작용에 의해 변퇴, 경화, 취하, 강도저하가 일어나는 단점을 보완하기 위해 내광성 및 내화학성이 우수한 전이금속산화물 소재와의 복합화를 통해 내광성 및 내화학성 개선에 대하여 연구하였다. zinc acetate 수화물과 수산화리튬을 무수에탄올로 용해시킨 용액을 강하게 교반하여 나노 산화아연 졸을 제조하였다. 제조된 나노크기의 zinc oxide 입자의 형상과 입자분포 등 제조특성을 입도분석기, FE-SEM 및 EDS 분석을 통하여 고찰하였으며, 제조된 나노졸을 아라미드 섬유에 침지시켜 Xenon-arc 내후성시험기에서 80시간 동안 노출시켜 노출시간에 따른 물성변화를 분석하였다. 나노졸을 5~20% 픽업으로 패딩한 후 광에 노출된 아라미드의 인장강도는 나노졸을 처리하지 않은 아라미드 섬유보다 20~30% 개선된 인장강도를 나타내었다.

  • PDF

Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL) (Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구)

  • Kang, Dong-Yeon;Son, Tae-Yoon;Joo, Yea-Il;Choi, Eung-Ho;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.