• Title/Summary/Keyword: x-ray PIV 기법

Search Result 16, Processing Time 0.024 seconds

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1475-1478
    • /
    • 2008
  • We have investigated the blood sucking phenomena of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism and eventually to develop a bio-mimic technology that can be used to resolve the problem encountered in the transport of infinitesimal biological fluids in various bio-chips and microchips. At first, the consecutive velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) system employed with a high-speed camera. The velocity signals of the blood-sucking flow in the proboscis represent a periodic pulsatile flow pattern and spectral analysis on the velocity waveform shows a clear peak at 6.1 Hz.

  • PDF

Advanced Flow Visualization Technologies and Blue Ocean Strategy (첨단 유동가시화 기법들과 Blue Ocean 전략)

  • Lee, Sang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.145-146
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, dynamic PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced measurement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. These would be indispensable in solving complicated thermo-fluid flow problems not only in the industrial fields such as automotive, space, electronics, aero- and hydro-dynamics, steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy engineering etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe most complicated nano- and bio-fluidic phenomena. In this presentation, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body will be introduced as a blue ocean strategy.

  • PDF

Advanced Flow Visualization Technologies and Blue Ocean Strategy (첨단 유동가시화 기법들과 Blue Ocean 전략)

  • Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.3-5
    • /
    • 2006
  • Recently, the next-generation advanced flow visualization techniques such as holographic PIV, aynni.c PIV, echo-PIV, micro/nano-PIV, and X-ray PIV have been introduced. These advanced mea-surement techniques have a big potential as the core technology for analyzing outmost thermo-fluid flows in future. They would be indispensable in solving complicated thermo-fluid flow problems not only in industrial fields such as automotive, space, electronics, aero- and hydro-dynamics. steel, and information engineering, but also in the research fields of medical science, bio-medical engineering, environmental and energy technology etc. Especially, NT (Nano Technology) and BT (Bio Technology) strongly demand these advanced measurement techniques, because it is impossible for conventional measurement methods to observe the nano- and bio-fluidic flow phenomena. In this article, the basic principle of these high-tech flow visualization techniques and their practical applications which cannot be resolved by conventional methods, such as blood flows in a micro-tube, in vivo analysis of micro-circulation, and flow around a living body are introduced as a blue ocean strategy.

  • PDF

A Tuberculosis Contact Investigation on Health Care Workers in One Hospital (일개 병원 내 의료종사자에서의 결핵 접촉자 조사)

  • Kim, Tae Hee;Jang, Yoon Suk;Jung, Sun Ju;Kim, Yeon Jae;Pai, Hyun Joo;Oh, Sung Hee
    • Pediatric Infection and Vaccine
    • /
    • v.23 no.2
    • /
    • pp.94-101
    • /
    • 2016
  • Purpose: This study aimed to describe the results of a contact investigation on health care workers after exposure to a house officer with smear-positive pulmonary tuberculosis (TB). Methods: Eighty nine out of 101 subjects who had close contact with the index patient agreed to be enrolled in the investigation. The first contact investigation was conducted approximately 30 days after the index patient's onset of symptoms, followed by the second investigation after 10 weeks. In both, clinical manifestations were studied, and chest X-ray and tuberculin skin test (TST)/QuantiFERON-TB Gold (QFT-G) in dual screening strategy were conducted. Results: The first TST resulted in positive in 34 subjects (38.2%). QFT-G was conducted on 16 subjects who tested positive in the first TST and aged under 36. Six of them (37.5%) were positive. The second TST was conducted on 41 subjects with negative results in the first TST. Seventeen (41.5%) were positive and among them, three (17.6%) showed positive QFT-G. None of the subjects were diagnosed with active TB. The probability of TB infection through contact with the index patient was 7.3% (3/41) in dual screening strategy while it was 41.5% (17/41) in TST strategy. Conclusions: This first hospital-setting contact investigation for tuberculosis in Korea revealed that latent tuberculosis infection (LTBI) rates vary depending on different diagnostic strategies. This indicates the need for systematic guidelines for diagnosing LTBI in health care workers who have professional exposure to TB.