• 제목/요약/키워드: x-ray

검색결과 16,670건 처리시간 0.044초

EDS 분석과 모델링에 의한 박막두께 측정 방법에 관한 연구 (Determination of Thin Film Thickness by EDS Analysis and its Modeling)

  • 윤재진;이원종
    • 한국전기전자재료학회논문지
    • /
    • 제24권8호
    • /
    • pp.647-653
    • /
    • 2011
  • In this study, a method to measure the thickness of thin film by EDS (energy dispersive spectroscopy) is suggested. We have developed a model which calculates the thickness of thin film from the characteristic x-ray intensity ratio of the elements in thin film and substrate by considering incident electron beam energy, x-ray generation curve, backscattering and absorption of x-ray, take-off angle of x-ray and tilt angle of the sample. We obtained the relation curve between the film thickness measured experimentally and the x-ray intensity ratio of elements. The film thicknesses calculated from the model agrees quite well with those measured experimentally. Therefore, the thin film thickness can be measured rapidly and accurately by using the model developed in this study and the x-ray intensity ratio obtained in EDS analysis.

X선회절에 의한 분말 고속도공구강의 구름접촉피로 해석 (Analysis of Rolling Contact fatigue for PM-High Speed Steel by X-ray Diffraction)

  • 이한영;노정균;배종수;김용진
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2000년도 제32회 추계학술대회 정기총회
    • /
    • pp.44-49
    • /
    • 2000
  • Recently, PM-high speed steel(PM-HSS) has reportedly been a good alternative material for rolling mill because of its superior peformance to conventional HSS. This paper has been aimed to investigate the possibility for application to rolling contact element for PM-HSS by X-ray diffraction technique. The X-ray elastic constant for PM-HSS has been found by X-ray diffraction during the four-point bending test. Residual stress and half-value breadth on the contact surface during rolling contact fatigue process by X-ray diffraction have also been measured. The result of this study shows that the application of X-ray diffraction technique to PM-HSS could be as possible alternative material as conventional HSS. Half-value breadth on rolling contact surface by X-ray diffraction is not changed during rolling contact fatigue process. On the other hand, the residual stress is changed. This suggests that dislocation reaction has been hardly occurred in rolling contact, depending on supersaturated carbon in PM-HSS.

  • PDF

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • 한국멀티미디어학회논문지
    • /
    • 제25권10호
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF

X-Ray 영상에서 고주파 성분 기반 동적 가우시안 필터를 이용한 피부와 뼈 영역 분할 기법 (Skin and Bone Segmentation Technique Using Dynamic Gaussian Filter Based on High Frequency Components in X-Ray Images)

  • 남윤만;박태언;김주완;송두헌;김광백
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.137-140
    • /
    • 2021
  • 본 논문에서는 X-Ray 영상에서 발 뼈의 골절 영역을 분석 및 진단하기 위한 전단계로서 X-Ray 영상에서 뼈와 피부 영역을 분할하는 방법을 제안한다. 제안된 방법은 X-Ray 영상의 피부 영역과 발 뼈 영역을 분할하기 위해 가우시안 필터를 적용하여 DOG 영상을 생성한다. 그러나 기존의 가우시안 필터는 정적으로 적용되기 때문에 영상을 촬영하는 부위와 각도에 따라 영상의 특성이 달라지는 X-Ray 영상에 적용하기에 부적합하다. 따라서 부위와 각도에 따라 영상의 특성 변화에 민감하지 않는 동적 가우시안 필터를 제안한다. 실험 결과에서는 제안하는 동적 가우시안 필터와 기존의 정적인 가우시안 필터를 각각 적용하여 생성된 DOG 영상에 대해서 발 뼈 영역과 피부 영역을 분할하고, 효율성을 TPR과 특이도로 분석한 결과, 제안된 동적 가우시안 필터를 적용한 방법이 정적 가우시안 필터보다 평균적으로 TPR는 0.12%와 특이도는 평균적으로 0.36%가 개선된 것을 확인하였다.

  • PDF

X-ray Response Characteristic of Zn in the Polycrystalline Cd1-xZnxTe Detector for Digital Radiography

  • Kang, Sang-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.28-31
    • /
    • 2002
  • The Cdl-xZnxTe film was fabricated by thermal evaporation for the flat-panel X-ray detector. The stoichimetric ratio and the crystal structure of a polycrystalline Cd$_{1-x}$ Zn$_{x}$Te were investigated by EPMA and XRD, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in the polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$_{0.7}$Zn$_{0.3}$Te thin film were measured to 0.37 nA/cm$^2$ and 260 pc/cm$^2$ at an applied voltage of 2.5 V/${\mu}{\textrm}{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$_{1-x}$ Zn$_{x}$Te detectors reduced the leakage current and improved the signal to noise ratio significantly.

X-Ray 진찰용 고전압 공진형 DC-DC 컨버터 설계 (High Voltage Resonant DC-DC Converter Design for X-Ray Imaging)

  • 백종무;주해종;조문택;이충식
    • 한국방사선학회논문지
    • /
    • 제4권4호
    • /
    • pp.11-16
    • /
    • 2010
  • 본 논문은 공진형 인버터로 구성된 X-ray 고전압 발생기와 고주파 고전압 변압기의 운영 시스템을 제안하였다. X선 발생장치는 무소음화와 소형화하였으며, 50[kHz]이상의 구동 주파수로 동작하게 하였고, 일반전원을 사용할 때 발생한 전력으로 인한 노이즈, 조사조건의 저하문제 등의 문제점을 해소하였다. 또한, X선관 전압 제어기와 관전류 제어기 및 고주파 고전압 변압기의 필라멘트 가열용 변압기를 고주파용으로 설계, 제작함으로써 X선 장치의 효율적 운영이 되도록 하였다.

X-ray dosimeter 개발을 위한 II-VI 족 화합물 반도체의 kVp 변화에 따른 특성 연구 (The study of characteristics of II-VI group chemical semiconductor by the kVp variation to development X-ray dosimeter)

  • 은충기;조승열;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.23-26
    • /
    • 1997
  • In exposuring x-rays, we can adjust three variables of kVp, mA and sec. The kVp is one of main factors affecting x-ray quality -peneterability. And miliampere-seconds is directly proportional to x-ray quantity. In this paper, we detected voltage variation of CdS, II-VI group semiconductor compounds, by kVp as the fundamental experiments of designing x-ray dosimeter. We exposured x-ray on the material from 40 to 100 kVp by increasing 2kVp using Shimadazu TH-500-125 Radio-Tex cx-s x-ray machine. We fixed miliampere -seconds to 100mA and 0.2 sec. After acquiring the raw data, we plotted the graph of kVp and voltage variation and figured slope value of 0.093 by regression. The standard deviation of voltage to kVp was 0.22. For the future study, the mAs variation study will be needed to investigate the connections between kVp and mAs in order to design x-ray dosimeter.

  • PDF

자동현상장치(自動現像裝置)의 현상액(現像液)과 정착액(定着液)의 관리(管理) (Study on the Management of the Developer and Fixing Solution for Automatic X-ray Film Processor)

  • 강홍석;김창균;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.61-67
    • /
    • 1978
  • Recently, Demands of automatic X-ray film processors are increasing more and more at general hospitals and private clinics, but various troubles because of incorrect control were found out. Authors have researched to find out the function and activity of automatic X-ray film processor for 70 days with Kodak X-OMAT processor, and results obtained were as follows; 1. Automatic X-ray film processor have an advantage to conduct the rapid treatment of X-ray film processing, but incorrect handling of developing and fixing agents were brought about a great change in contrast and optical density of X-ray film pictures. 2. About 10,000 X-ray films could be finished by same developing and fixing solution without exchanging any other solutions in automatic X-ray film processor.

  • PDF

원판형 연골에서 단순 방사선 검사의 의의 (X-ray Significance in Discoid Meniscus)

  • 안진환;하권익;김형국;김호
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.102-107
    • /
    • 1997
  • Discoid meniscus has been well known to a frequent anomaly of meniscus and much reported in diagnosis and treatment. But, associated X-ray findings have not been known well. We reported its significance of X-ray findings in discoid meniscus. From May 1995 to May 1997, 31 cases of discoid meniscus were compared with 51 cases of nondiseoid meniscus both confirmed by arthroscopy, with simple X-my findings. Both groups were evaluated by X-ray findings in view of lateral joint space widening, peripheral spur of lateral joint space, sclerotic change of lateral tibial plateau, concave lateral tibial plateau, flattening of lateral femoral condyle, hypoplasia of lateral femoral condyle and high riding fibula. The results of analysis were as follows: 1. Widening of lateral joint space, sclerotic change of lateral tibial plateau and cupping of lateral tibial plateau were statistically significant in discoid meniscus. 2. X-ray findings in discoid meniscus were not associated with patient's injury history and symptom duration. 3. Other X-ray findings were not related in discoid meniscus significantly. X-ray findings with patient's history and physical examination arc helpful in the diagnosis of discoid meniscus.

  • PDF