• Title/Summary/Keyword: wrist pulse

Search Result 65, Processing Time 0.027 seconds

Pulse Wave Velocity Measured by Radial Artery Clip-type Pulsimeter Equipped with a Hall Device and Electrocardiogram (홀소자가 구비된 요골동맥 집게형맥진기와 심전도로 측정된 맥파전달속도)

  • Lee, Kyu-Hwan;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.130-134
    • /
    • 2013
  • The clip-type pulsimeter equipped with a magnetic sensing Hall device and the most popular body sign of the electrocardiogram (ECG) were investigated in order to analyze the pulse wave velocity (PWV). The PWV simultaneously calculated by means of time difference between the maximum peak of ECG pulse wave and the starting point of radial artery pulse wave, and distance difference between the heart position and the radial wrist position. The PWV analyzed from the clinical data was a wider scope of 5~7 m/s with an average value of 6 m/s. By the prediction of blood vessel's elasticity from the analysis of PWV, it may be useful for developing an oriental-western diagnostic medical signal device for a U-health-care system in the future.

A Wearable Watch-type Reflectance-based Blood-oxygen Saturation (SpO2) Level Estimation (반사광을 이용한 손목시계형 혈중산소포화도 (SpO2) 측정기)

  • Lee, Hooseok;Thap, Tharoeun;Lee, Jinseok
    • Annual Conference of KIPS
    • /
    • 2015.10a
    • /
    • pp.578-579
    • /
    • 2015
  • Transmission and reflectance are two non-invasive techniques to perform pulse oximetry. This paper presents a design of reflectance-based pulse oximetry for watch-type wearable device, in which sensor and detector are located on the same surface of the body part. The basic principle of a pulse oximeter is based on the measurement of the red and infrared (IR) light absorption. Oxygenated blood has significant differences of light absorption characteristics than deoxygenated blood under red (660 nm) and infrared (940 nm) wavelength. Infrared is absorbed more by oxygenated hemoglobin than red. So the hardware implementation is included placing of the two LEDs (red and IR) with single photo-detector in the middle on the patient's wrist to get the corresponding pulsatile signals which are used to estimate the $SpO_2$.

Implementation of Low-Power Ubiquitous Health System based on Real-Time Embedded Linux using ZigBee wireless communication (ZigBee를 이용한 실시간 임베디드 리눅스 기반의 저전력형 U-Health 시스템 구현)

  • Kwon, Jong-Won;Ayurzana, Odgerel;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.436-438
    • /
    • 2007
  • As the sensors and communication technology get advance, the remote health diagnosis for patients and senior persons at home are possible now without visiting doctors in hospitals. A low-power ubiquitous health check device was developed adapting Real-Time Embedded Linux is developed. This ubiquitous device is consisted of three sensors. The wrist type health checking terminal acquires periodically the health data by using a blood pressure sensor, a pulse sensor and a body temperature sensor. It transmits the health data to the access point located at the home center through the ZigBee wireless communication modem. This health data collector or access point device sends the data again to the main server operated in a hospital or health care organization. The health server control continuously the input data and sends an alarm signal to the assigned. doctor and responsible persons using cellular SMS when any dangerous events occur. This wrist type health check device has an embedded linux OS using Intel PAX255 MPU. The developed U-Health system is applicable for checking patients health in remote at home. And their family or related persons in remote site can check the patients health status at any time. They can be assured by receiving SMS record and alarm of emergency case which is transmitted from the health server.

  • PDF

Wrist Wearable Device for the Measurement and Analysis of Physiological Signals (생체신호 측정 및 분석을 위한 손목 착용형 단말기)

  • Im, Jae Joong;Li, Ming Kui;Hwang, Chan Song
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.65-73
    • /
    • 2012
  • Wrist wearable device for the measurement of pulse rate, ECG, and activity during normal daily life, which could be used for the continuous monitoring and remote transmission of acquired data, was developed. Pressure sensor, device attached electrodes, and 3-degree accelerometer were used. Analysis algorithm and firmware program were established for providing diagnostic information for the users. Results of this study, possible for the management of health report and transmission of the results through bluetooth by wearing simple personal wrist device, could be used for the development of portable device in the u-healthcare environment.

A Study on the Cun, Guan, Chi (Inch, Bar, Cubit) from the Elementary Course for Medicine{Yi Xue Ru Men) (의학입문(醫學入門)의 촌관척(寸關尺)에 관한 고찰(考察))

  • Lee, Soo-Kyeung;Park, Won-Hwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.2
    • /
    • pp.10-24
    • /
    • 2005
  • Background and Purpose: Feeling the pulse is based on the pulse condition and alteration to observe the condition of the human body's health and by using a healthy person's pulse as a standard we are able to analyze the patient's pulse to find the attacked channel and collateral, viscera and bowels and understand the pathology such as diseases caused by exogenous evil, disorder of internal organs, and seven modes of emotions. Observing the color and shade of the patient's face, listening carefully to the sound of the patient, and feeling the pulse are methods in accordance with Su Wen 'Plain Questions', 'The Classic on Difficulty' (5th century B.C. Bianque), 'The Classic of Sphymology' (280 A.D. Wang Xi), 'Pulse Formulas' (1189 A.D. Cui Jiayan), and is systematically edited for those who have started studying to easily reach the profound state. Therefore, 'The Elementary Course for Medicine' has been used from ancient times as the textbook for diagnostics. Methods: In this Study, we will inspect commonly used pulse feeling methods, the inch, bar, cubit thesis, the viscera and bowels thesis from The Elementary Course for Medicine and inquire the difference of the text from 'Plain Questions of Huangdi's Internal Classic', 'Treatise on Febrile Diseases', 'Classic on Difficulty'. Results and Conclusion: 1. In 'The Elementary Course for Medicine' the site of the wrist along the pulsation of the radial artery is divided into inch, bar, cubit and has defined the inch, bar, cubit crossways. 2. In 'The Elementary Course of Medicine' the inch, bar, cubit for the left hand and right hand is subjected to each viscera and bowel. By assigning the left hand's inch, bar, cubit to the cardial orb, the hepatic orb, the renal orb, and the right hand's inch, bar, cubit to the pulmonic orb, the splenic orb, the vital gate it has been able to feel the pulse for each viscera and bowel by using the interpromoting and interacting relation of the five evolutive phases.

  • PDF

Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.239-244
    • /
    • 2017
  • Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

An Experimental Study on the Correlationship Between Highrised Safetyguard and Workers' Safety (안전난간유형에 따른 작업자 안전의 상관관계에 대한 실험적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.80-84
    • /
    • 2001
  • Work stress and health are very important factors related to workers' condition and work safety, Author has conducted a couple of tests to check up three people's pulses before they work during their work for three types of safety guard in construction site. Work type, age, weight, sex experience year, ambient temperature n recorded as variables in this study. These are checked and asked by the author directly, before their pulse check Also, workers' Pulses were measured at height H-0 and H-9.0m to understand psychological the degree of psychological nervousness degree. POLAR protrainer NVTM HRM system(wrist recorder and sensor) was used for the site test. There are three(3) different types of construction safety guard which have been used for, this study. They are usually or frequently used and found in the site. Four different ranges of age groups(20's, 30's 40's, 50's) carpenters are assisted to the test sites with wearing pulse recorder and sensor respectively. All three types of safety guards have the same height 90㎝ even though they are different types. On top of five(5) stories tublar framed scaffolding is fabricated, similar to the one in site, where those safety guards are installed. The older(=more experienced) the workers are the more stable they are. it is shown. Also, It is verified the visually uncomfortable rail type can cause workers to psychologically be unstable.

  • PDF

Classification Model of Chronic Gastritis According to The Feature Extraction Method of Radial Artery Pulse Signal (맥파의 특징점 추출 방법에 따른 만성위염 판별 모형)

  • Choi, Sang-Ho;Shin, Ki-Young;Kim, Jeauk;Jin, Seung-Oh;Lee, Tea-Bum
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.1
    • /
    • pp.185-194
    • /
    • 2014
  • One in every 10 persons suffer from chronic gastritis in Korea. Endoscopy is most commonly used to diagnose the chronic gastritis. Endoscopic diagnosis is precise but it is accompanied with pain and high cost. According to pulse diagnosis in Traditional East Asian Medicine, health problems in stomach can be diagnosed with radial pulse signals in 'Guan' location in the right wrist, which are non-invasive and cost-effective. In this study, we developed a classification model of chronic gastritis using pulse signals in right 'Guan' location. We used both linear discrimination method and logistic regression model with respect to pulse features obtained with a peak-valley detection algorithm and a Gaussian model. As a result, we obtained sensitivity ranged between 77%~89% and specificity ranged between 72%~83% depending on classification models and feature extraction methods, and the average classification rates were approximately 80%, irrespective of the models. Specifically, the Gaussian model were featured by superior sensitivities (89.1% and 87.5%) while the peak-valley detection method showed superior specificities (82.8% and 81.3%), and the average classification rate (sensitivity + specificity) of the Gaussian model was 80.9% which was 1.2% ahead of the peak-valley method. In conclusion, we obtained a reliable classification model for the chronic gastritis based on the radial pulse feature extraction algorithms, where the Gaussian model was featured by outperformed sensitivity and the peak-valley method was featured by outperformed specificity.

Development of EMG-Triggered FES System and Optimal Electrode Location for Chronic Hemiplegic Patients (편마비 환자를 위한 근전도 유발 기능적 전기자극기의 개발과 이상적인 전극부착 위치)

  • 박병림;안상호;정호춘;진달복;김성곤;이상세;김영기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.151-156
    • /
    • 2004
  • The purpose of this study was to develop EMG triggered FES system for restoration of upper extremity function in chronic hemiplegic patients and to identify the optimal location of electrode application for the EMG triggered FES system which produces effective muscle contraction and detects EMG activity for extension in the wrist and finger joints. The stimulus system was composed of EMG measuring component, constant current component and the program for muscle contraction by EMG triggered FES and passive FES. Parameter of electrical stimulation was 35 ㎐ in frequency, 150 ${\mu}\textrm{s}$ in pulse width and symmetric bi-phasic wave. In 15 hemiplegic patients, EMG triggered FES was applied to the proximal half of forearm which was divided into 12 areas. The most sensitive area for measuring EMG activities during extension of the wrist and fingers was area 4, 5 and the optimal location of electrical stimulation for producing extension of the wrist and fingers was area 4, 5, 7, 8. These results suggest that the area 4 and 5 was considered as the most optimal location of electrode application for measuring EMG activities as well as producing extension of the wrist and fingers by EMG triggered FES system.

Design and Implementation of a Wearable $SpO_2$ Module based WSN (무선센서네트워크 기반의 손목 착용형 $SpO_2$ 모듈 설계 및 구현)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.495-498
    • /
    • 2008
  • This paper describes design of a real-time, wearable reflectance pulse oximetry which is based Wireless Sensor Network. For the purpose of continuously monitoring vital signs of a human, wearable reflectance pulse oximetry is built into a wrist type that can be obtained $SpO_2$ value of patient unobtrusively. This designed $SpO_2$ module is based on a low-power 8 bit ATmega128L microcontroller operating in 3V. Low power operating $SpO_2$ module was integrated to wireless sensor node for user's health monitoring. This paper is focused on the successful integration of all these components into wearable reflectance pulse oximetry and evaluates its ability to measure patient' $SpO_2$ value. Information from this sensor was wirelessly transmitted to a base-station for storage and display purposes.

  • PDF