• 제목/요약/키워드: working fluid of ammonia

검색결과 39건 처리시간 0.024초

R744-R717 캐스케이드 냉동시스템에서 운전조건 변화에 따른 성능 해석 (Performance Simulation of a R744-R717 Cascade Refrigeration System According to Operating Conditions)

  • 유지호;조홍현
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.497-505
    • /
    • 2015
  • The evaporating temperature range required for the low temperature freezing system is from $-50^{\circ}C$ to $-30^{\circ}C$. Since it is difficult to keep the required capacity in a cabinet, it is advantageous to design the system using a cascade refrigeration system. Use of carbon dioxide and ammonia would be advantageous since ammonia is an environment-friendly working fluid and has a high capacity for performance improvement. To investigate the performance characteristics of the R744-R717 cascade refrigeration system, a theoretical model was developed and performance was analyzed according to cascade heat exchanger operating temperature. The optimal cascade R744 condensing temperature was $-5^{\circ}C$, and maximum COP was 1.13 when the temperature difference of the cascade heat exchanger was $5^{\circ}C$. In addition, the total system COP increased by 1.17 when the cascade temperature gap was $3^{\circ}C$ at the middle temperature of $-7.5^{\circ}C$.

축방향 사다리꼴 그루브 히트파이프의 열성능에 대한 실험적 연구 (Experimental Study of Thermal Performance of Heat Pipe with Axial Trapezoidal Grooves)

  • 서정세;이운
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.407-414
    • /
    • 2003
  • Analysis and experiment are performed to investigate the thermal performance of a heat pipe with axial grooves. The heat pipe was designed in a 6.5 mm I.D., 17 axial trapezoidal grooves. 1000 mm long tube of aluminium, and ammonia as working fluid. A mathematical equations fur heat pipe with axial grooves is formulated to obtain the capillary limitation on heat transport rate in a steady state. As a result, heat transport factor of heat pipe has the maximum at the operating temperature of 293K in 0m elevation. As the elevation of heat pipe increases. the heat transport factor of the heat pipe is reduced markedly, comparing with that of horizontal elevation of the heat pipe. It may be considered that such behavior of heat pipe is caused by the working fluid swarmed back to the condenser port due to gravity force and supercooled by a coolant of heat exchanger. Analytical results of heat transport factor are in a good agreement with those of experiment.

저온 열원 및 LNG 냉열을 이용하는 복합 발전 사이클의 성능 해석 (Performance Analysis of a Combined Power Cycle Utilizing Low-Temperature Heat Source and LNG Cold Energy)

  • 김경훈;오재형;고형종
    • 한국수소및신에너지학회논문집
    • /
    • 제23권4호
    • /
    • pp.382-389
    • /
    • 2012
  • Power generation cycle using ammonia-water mixture as working fluid has attracted much attention because of its ability to efficiently convert low-temperature heat source into useful work. If an ammonia-water power cycle is combined with a power cycle using liquefied natural gas (LNG), the conversion efficiency could be further improved owing to the cold energy of LNG at $-162^{\circ}C$. In this work parametric study is carried out on the thermodynamic performance of a power cycle consisted of an ammonia-water Rankine cycle as an upper cycle and a LNG cycle as a bottom cycle. As a driving energy the combined cycle utilizes a low-temperature heat source in the form of sensible heat. The effects on the system performance of the system parameters such as ammonia concentration ($x_b$), turbine 1 inlet pressure ($P_{H_1}$) and temperature ($T_{H_1}$), and condenser outlet temperature ($T_{L_1}$) are extensively investigated. Calculation results show that thermal efficiency increases with the increase of $P_{H_1}$, $T_{H_1}$ and the decrease of $T_{L_1}$, while its dependence on $x_b$ has a downward convex shape. The changes of net work generation with respect to $P_{H_1}$, $T_{H_1}$, $T_{L_1}$, and $x_b$ are roughly linear.

마그네틱 커플링으로 연결된 터빈-발전기 시스템의 로터다이나믹 해석 및 실험적 고찰 (Rotordynamic Analysis and Experimental Investigation of the Turbine-Generator System Connected with Magnetic Coupling)

  • 김병옥;박무룡;최범석
    • 한국유체기계학회 논문집
    • /
    • 제16권3호
    • /
    • pp.32-38
    • /
    • 2013
  • This paper deals with the study on the rotordynamic and experimental analysis of turbine-generator system connected with a magnetic coupling. Although magnetic coupling has been used to torque transmission of chemical processing pump rotating at under 3,600rpm, magnetic coupling in this study is applied to high-speed turbine-generator system using a working fluid that is refrigerant such as ammonia or R-124a. Results of rotordynamic design analysis are as follows. The first, shaft diameter nearest to outer hub of magnetic coupling has a big effect on the $1^{st}$ critical speed of generator rotor. The second, if the $1^{st}$ critical speeds of turbine rotor and generator rotor have enough to separation margin in comparison to rated speed, the $1^{st}$ critical speed of turbine-magnetic coupling-generator rotor train has enough to separation margin regardless of connection stiffness of magnetic coupling. The analytical FE model is guaranteed by impact test on the prototype and condition monitoring such as measurements of vibration and bearing temperature is also performed.

상향류식 연속역세여과를 이용한 양어장 순환수 재이용(I) (Treatment of Recycling Wastewater of Aquaculture Using DynaSand Filter( I ))

  • 박종호;김이오;황규덕;황금희;조규석;김동식
    • 한국양식학회지
    • /
    • 제15권2호
    • /
    • pp.87-93
    • /
    • 2002
  • 양어용수 재순환을 위한 생물여과상의 처리효율을 향상시키기 위하여 상향류식 연속역세여과장치를 이용하여 다양한 조건하에서 실험하였는데, 기존의 연속역세여과장치와 이를 개량한 연속역세여과장치를 가지고 실험하였다. 개량역세여과장치는 기존에 이용되고 있는 DynaSand 여과장치를 유체역학 및 물리,화학적 개념을 응용한 장치로 개조하여 역세기능의 향상, 산소전달 능력의 향상, 여과 처리수 인출부의 개량에 의한 처리수 탁도제거 기능 향상 및 연속적인 수두손실 감지에 의해 폐수성상에 따른 여과장치운전의 자동화를 도모하는데 중점을 두었고, 또한 여과사의 표면을 특정물질로 코팅함으로 여과사 표면전하를 변화시켜 여과능력의 향상과 생물막 형성력의 증대를 꾀하는데 실험의 목적을 두었다. 본 실험에서 사용 한 여과장치의 크기는 전체 용적이 약 70 L이고 working volume은 35 L이었다 이번 연구에서 양어장사육용수 처리를 위해 조사된 개량형 상향류식 연속역세여과장치의 효율은 부유물 제거 효율이 평균 71% 이었고, NH$_4$$^{+/-N}$ , T-P및 SRP의 제거효율은 84%, 85% 및 88%로 각각 나타나서 그 효과가 인정되었다.

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

산업폐기물 소각플랜트의 작업환경개선 (Improvement of Working Surroundings in the Industrial Waste Incinerator)

  • 손병현;이강우
    • 한국산학기술학회논문지
    • /
    • 제7권3호
    • /
    • pp.431-439
    • /
    • 2006
  • 산업폐기물소각로에서 폐기물을 처리 시 폐기물 투입공정이나 전처리공정에서 많이 발생하는 오염물질인 입자상물질과 악취 등은 작업자의 작업능률의 저하를 초래하므로, 본 연구에서는 이러한 문제를 해결하기 위해 새로운 형태의 오염물질 저감설비를 설치하여 작업환경을 개선하고자 하였다. 전산유체역학을 이용하여 산업폐기물소각로에서 발생하는 오염물질의 확산경로를 예측하였으며, 이 결과를 이용하여 오염물질 저감설비의 형태와 설치 위치를 결정하였다. 오염물질 저감설비를 설치한 후, 드럼폐기물 보관장(사이트 1)과 폐합성수지 보관장(사이트 2)에서 톨루엔 83-97%, 스티렌 48-72%, 크실렌 75-87%, 암모니아 23-36%의 저감효과를 보였으며, 또한 PM-10과 TSP는 폐기물 투입구 하단부(사이트 3)에서 각각 87%와 86%, 폐기물 투입구 옆부분(사이트 4)에서 각각 87%와 85%의 저감효과를 보였다. 본 연구에서 설계한 새로운 형태의 오염물질 저감설비는 입자상물질과 악취의 제거에 뛰어난 성능을 보여 산업페기물소각로를 운용하는 다른 페기물처리업체에 적용할 수 있을 것으로 판단된다.

  • PDF

Zeta-potential을 이용한 이성분 나노유체의 분산안정도 측정 (Measurement of distribution stability of binary nanofluids by zeta-potential)

  • 이강일;정청우;김현준;정진희;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.52-57
    • /
    • 2006
  • This study investigates the distribution stability of binary nanofluids where binary mixtures such as $NH_3/H_2O$ and $H_2O/LiBr$ solution are used as a base fluid. When a little amount of certain nanosized particles is added into a basefluid, the thermal conductivity of that mixture increases greatly. Such mixtures are named 'nanofluids' where nano-particles should be distributed stably and uniformly so the distribution stability of nanoparticles in nanofluids is one of the most important factors for nanofluid application. Therefore, binary nanofluids in which binary mixtures are applied as the basefluids are considered as working fluids. The kind and the concentration of nanoparticles, and the concentration of ammonia are considered as the key parameters. The objectives of this paper are to visualize the dispersed status of particles in binary nanofluids and to find the effect of key parameters on the distribution stability in the ammonia absorption system.

  • PDF

전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계 (Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology)

  • 권경석;이인복;황현섭;;홍세운;서일환;최지선;송상현;문운경
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.