• Title/Summary/Keyword: work zones

Search Result 181, Processing Time 0.025 seconds

The Effect of ZnO Content on the Performance of Spray-dried Zn-based Desulfurization Sorbent for H2 Cleanup (황화수소 정제용 아연계 분무건조 탈황제의 활성성분 함량 변경에 따른 물성 및 반응 특성)

  • Baek, Jeom In;Eom, Tae Hyoung;Lee, Joong Beom;Jegarl, Seong;Ryu, Chong Kul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.482-490
    • /
    • 2014
  • Gaseous sulfur compound such as $H_2S$ or COS in coal- or biomass-derived hot syngas can be purified by solid sorbents at high temperatures. In this study, we investigated the physical properties and reactivity of solid regenerable desulfurization sorbents with 37.2, 41.9, and 46.5wt% ZnO to look into the ZnO content effect. The sorbents were produced by spray-drying method to apply to a fluidized-bed process. Sulfidation and regeneration reaction were carried out using a thermogravimetric analyzer. Sorbent prepared with 46.5wt% ZnO had physical properties suitable for a fluidized-bed process applications such as spherical shape, sufficient mechanical strength and density, high porosity and surface area. It showed high sulfur sorption capacity of 10.4wt% (ZnO utilization of 57%) at reaction temperatures of 500 and $650^{\circ}C$ for sulfidation and regeneration, respectively. However, the sulfur sorption capacity and ZnO utilization were significantly reduced and dimple shape appeared when the ZnO content decreased to 37.2 and 41.9wt%. Sulfur sorption capacity and regenerability were improved as reaction temperature increased within the experimental temperatures used in this work. The reaction temperature zones of $1500{\sim}550^{\circ}C$ and $650{\sim}700^{\circ}C$ are recommended for sulfidation and regeneration, respectively, to lead best reaction performances of the ZnO-based spray-dried sorbents developed in this work.

Exclusion zones for GNSS signals when reconfiguring receiver hardware in the presence of narrowband RFI

  • Balaei, Asghar T.;Dempster, Andrew G.;Barnes, Joel
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.347-352
    • /
    • 2006
  • Narrowband interference can severely degrade the performance of GPS receivers. Detecting the presence of interference and then characterizing it can lead to its removal. Receivers can be reconfigured to focus on other signals or satellites that are less vulnerable to that interference at that moment. Using hardware reconfigurability of FPGA receivers and characterizing the effect of narrowband interference on the GNSS signal quality lead us to a new RFI mitigation technique in which the highest quality and less vulnerable signal can be chosen at each moment. In the previous work [1], the post processing capability of a software GPS receiver, has been used to detect and characterize the CW interference. This is achieved by passing the GPS signal and the interference through the correlator. Then, using the conventional definition of C/No as the squared mean of the correlator output divided by its variance, the actual C/No for each satellite is calculated. In this work, first the 'Exclusion zone' for each satellite signal has been defined and then by using some experiments the effects of different parameters like signal power, jamming power and the environmental noise power on the Exclusion zone have been analyzed. By monitoring the Doppler frequency of each satellite and using the actual C/No of each satellite using the traditional definition of C/No and actual data from a software GPS receiver, the decision to reconfigure the receiver to other signal can be made.

  • PDF

A Study on Red Hill Copper Deposits of the Dongjom Mine (동점광산(銅店鑛山)의 붉은등 광체(鑛體)의 성인(成因)에 관한 연구(硏究))

  • Kim, Ok Joon;Kim, Kyu Han
    • Economic and Environmental Geology
    • /
    • v.7 no.4
    • /
    • pp.157-173
    • /
    • 1974
  • The Red Hill deposit of the Dongjom Copper Mine is the most promising deposit of the mine and under intensive exploration at present although there are eight more deposits of vein type. With total 2160m drilling of 9 holes completed and 400m drilling on two holes underway, the nature of the Red Hill deposit has come more clear. The copper content in the whole ore body is meager so far as the exploration done up to present indicates, but there are evidences that mineralization covers all over the granodiorite cupola at the Red Hill area. The petrological work and assay on the samples taken by the writers indicate that granodiorite rocks can be divided into fresh zone and alteration zone. Alteration zone consists of potassic and argillic zones accompanyied by silicification zone on basis of Lowell and Guilbert model Argillic zone has closely related with a mineralization in the Red Hill deposit. It has been cleared that the alteration acompanyied with the mineralization took place not only &long vertical fissures but also in the irregular lateral zone, the nature of which is unknown. Judging from the results of exploration and petrochemical study on the Red Hill deposit which is imbedded in a southern part of the granodiorite cupola, it can be concluded by the writer's opinion that the Red Hill deposit is possibly a porphyry copper deposit, because the shape of the ore body, mineral zoning and paragenesis and wall rock alteration resemble to those of typical porphyry copper deposits. It is the writers' opinion that more exploration work is required so as to evaluate the deposit.

  • PDF

Investigation of Microbial Contamination and Working Environment in University Foodservices (대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

Yield and Fracture of Paper

  • Park, Jong-moon;James L. Thorpe
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.31 no.5
    • /
    • pp.57-72
    • /
    • 1999
  • Traditional theories of the tensile failure of paper have assumed that uniform strain progresses throughout the sheet until an imperfection within the structure causes a catastrophic break. The resistance to tensile elongation is assumed to be elastic , at first, throughout the structure, followed by an overall plastic yield. However, linear image strain analysis (LISA) has demonstrated that the yield in tensile loading of paper is quite non-uniform throughout the structure, Traditional theories have failed to define the flaws that trigger catastrophic failure. It was assumed that a shive or perhaps a low basis weight area filled that role. Studies of the fracture mechanics of paper have typically utilized a well-defined flaw around which yield and failure could be examined . The flaw was a simple razor cut normal to the direction of tensile loading. Such testing is labeled mode I analysis. The included fla in the paper was always normal to the tensile loading direction, never at another orientation . However, shives or low basis weight zones are likely to be at random angular orientations in the sheet. The effects of angular flaws within the tensile test were examined. The strain energy density theory and experimental work demonstrate the change in crack propagation from mode I to mode IIas the initial flaw angle of crack propagation as a function of the initial flaw angle is predicted and experimentally demonstrated.

  • PDF

Optimal stiffness distribution in preliminary design of tubed-system tall buildings

  • Alavi, Arsalan;Rahgozar, Reza
    • Structural Engineering and Mechanics
    • /
    • v.65 no.6
    • /
    • pp.731-739
    • /
    • 2018
  • This paper presents an optimal pattern for distributing stiffness along a framed tube structure through an analytic equation, which may be used during the preliminary design stage. Most studies in this field are computationally intensive and time consuming, while a hand-calculation method, as presented here, is a more suitable tool for sensitivity analyses and parametric studies. Approach in development of the analytic model is to minimize the mean compliance (external work) for a given volume of material. A variational statement of the problem is made, and a specified deformation-profile is obtained as the necessary condition for a minimum; enforcing this condition, stiffness is then computed. Due to some near-zero values for stiffness, the problem is modified by considering a lower bound constraint. To deal with this constraint, the design domain is assumed to be divided into two zones of constant stiffness and constant curvature; and the problem is restated in terms of these concepts. It will be shown that this methodology allows for easy computation of stiffness through an analytic and dimensionless equation, valid in any system of units. To show practicality of the proposed method, a tubed-system structure with uniform stiffness distribution is redesigned using the proposed model. Comparative analyses of the results reveal that in addition to simplicity of the proposed method, it provides a rather high degree of accuracy for real-world problems.

An experimental performance analysis of a cold region stationary photovoltaic system

  • Choi, Wongyu;Warren, Ryan D.;Pate, Michael B.
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.1-28
    • /
    • 2016
  • A grid-connected photovoltaic (PV) system comprised of multicrystalline silicon (mc-Si) modules was installed in a cold climate region in the U.S. This roof-mounted stationary PV system is a real-world application of PV for building energy generation in International Energy Conservation Code (IECC) Climate Zone 5 (and possibly similar climate zones such as 6, 7 and 8), and it served the purposes of research, demonstration, and education. The importance of this work is highlighted by the fact that there has been less emphasis on solar PV system in this region of the U.S. because of climate and latitude challenges. The system is equipped with an extensive data acquisition system capable of collecting performance and meteorological data while visually displaying real-time and historical data through an interactive online interface. Experimental data was collected and analyzed for the system over a one-year period with the focus of the study being on measurements of power production, energy generation, and efficiency. The annual average daily solar insolation incident upon the array was found to be $4.37kWh/m^2$. During the first year of operation, the PV system provided 5,801 kWh (1,264 kWh/kWp) of usable AC electrical energy, and it was found to operate at an annual average conversion efficiency and PR of 10.6 percent and 0.79, respectively. The annual average DC to AC conversion efficiency of the inverter was found to be 94 percent.

The Safety Assessment of Embankment by Three Dimensional Electrical DC Modeling (3차원 전기비저항 모델링을 통한 제체의 안정성 분석 연구)

  • Oh, Seok-Hoon
    • Journal of the Korean earth science society
    • /
    • v.29 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Recently, the electrical DC survey has frequently been performed to assess the safety of embankment. This study showed that the damaged section of embankment could be appropriately detected by the survey only when the three dimensional effect was correctly considered. The shape of the three dimensional embankment was numerically implemented, and a proper modeling was performed to confirm the effect by analyzing the apparent and inverted true resistivity. Then, the field work was carried out. The three dimensional interpretation distinguished the erroneous weak zones from the geometrical artifact, and the embankment was ensured as safe both by the additional survey performed in rainy season and the partial excavation for direct observation.

An exosolar planetary system N-body simulator II

  • Hong, ChaeLin;van Putten, Maurice
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.46.3-47
    • /
    • 2018
  • We present a general N-body exasolar system simulator in anticipation of upcoming searches for exoplanets and even exomoons by next generation telescopes such as James Webb Space Telescope. For habitable zones, traditionally defined by temperature, we here address the essential problem of dynamical stability of planetary orbits. Illustrative examples are presented on P-type orbits in stellar binary systems, that should be fairly common as in Kepler 16b. Specific attention is paid to reduced orbital lifetimes of exoplanets in the habitable zone by the stellar binary, that is propoesed by Maurice van Putten (2017). Especially, we focused on a classic work of complex three-body problem that is well known by Dvorak(1986). We charge his elliptic restricted three-body problem to extend unrestricted three-body problem to look into dynamical motions in view of circumbinary planet, furthermore, we suggest that opposite angular orientation of the planet is relative to the stability of orbits. In here, counter-rotation case is relatively more faster than co-rotation case for being stable. As a result, we find that various initial conditions and thresholds to approach dynamical stability and unstability with unexpectable isolated islands over enormous parameter space. Even, superkeplerian effect of binary is important to habitability of the exoplanet and we can verify that superfaster binary doesn't effect on th planet and increases survivality of planet around the binary.

  • PDF

A Study on the Welfare Services and Their Grouping in Welfare Complexes -Focused on Urban Area (복합복지시설의 서비스기능 및 서비스 그룹화에 관한 연구)

  • Kwon, Soonjung;Choi, Kyungsook;Oh, Eunjin;Kim, Sanggil;Sung, Gichang;Park, Hyesun;Kim, Seokjoon;We, Kwonil;Shin, Heejin;Jung, Eunyoung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.17-24
    • /
    • 2010
  • At the moment many welfare complexes are being constructed in Korea as the welfare demand of contemporary society increases. However, there are a few useful guidelines for the planning of the welfare complexes. So it is not easy for the local governments to work out the proper plan for the construction of welfare complexes for their own. This study has been started in order to provide basic informations for the planning of Korean welfare complexes. The result of this study can be summarized into two points. The first one is that 8 welfare services (elderly, women, children, nursery, adolescence, handicapped, health care, public support) are necessary in general welfare complexes in local governments. The second one is that 4 welfare zones are desirable for the planning of welfare complexes. For example, the 1st zone is consist of welfare services for the adolescence, women and children, the 2nd zone for the elderly, handicapped, the 3rd zone for the public support and the 4th zone for the health care.