• Title/Summary/Keyword: wireless communication (Zigbee, CDMA)

Search Result 8, Processing Time 0.031 seconds

A study on the street security light management system using Zigbee network (지그비 통신망을 이용한 보안등 관제 시스템에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.430-436
    • /
    • 2014
  • This paper relates to the study about the street security light management system. The purpose of the wireless remote management system is to manage street security lights efficiently. The system is composed of three components like light controller, CDMA gateway and web based remote management server. The zigbee solution is adopted to make local wireless network between street security lights. The CDMA network is used for the wireless communication between street security light controller and the remote control center. The gateway to interconnect zigbee network and CDMA was designed with low power 32 bits Cortex M3 micro-controller. For the data communication between the management server and the gateway, SMS and socket based TCP streaming is used. The management server sends SMS to the gateway to deliver light control and management requests, and the gateway replies with the light controllers report via TCP streaming. By using both SMS and TCP streaming communication, it was verified that simple cost effective management is possible for street security lights. We tried real test for 95 street security lights in real environment during two months and analyzed the practical possibility for mass supply.

Implementation of the Disaster Monitering System with PLC/CDMA Environments (PLC/CDMA 환경에서의 재난 감시 시스템 구현)

  • Park, Sang-Hwan;Kim, In-Min;Yoon, Seon-Tae;Park, Ki-Won;Go, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.824-830
    • /
    • 2010
  • PLC_Zigbee system, implemented in a previous study, uses ZigBee Node based on PLC (Power Line Communication). The weak point of the system is that the long distance powerline communication and PLC is impossible to use in the areas where the powerline is not installed. In this paper, we added CDMA (Code Division Multiple Access) module using a data transfer method of SMS (Short Message Service) and XBee of WSN (Wireless Sensor Network) module to the previous system, and got around the restriction of place and environment of PLC system through the interfacing of each communication media. We, thus, implemented a wide range of real monitoring system.

Development of Realtime Ubiquitous River Monitoring System (실시간 유비쿼터스 하천정보 모니터링 시스템의 개발)

  • Jang, Bok-Jin;Lee, Jong-Kook;Yeo, Woon-Kwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1305-1312
    • /
    • 2006
  • This study is about the development of measurement system using ubiquitous wireless communication for river flow monitoring. The system can acquire water depth, quality (temperature, pH, conductivity, turbidity etc.) while a GPS module for getting the location data of measurement points. Also this system is able to acquire the field data via RF connection and can be controlled same time. The acquired data is transmitted to a gateway system from the remote buoy using Zigbee wireless connection. And the gateway system is able to monitor the data through GIS monitoring tool. Finally the data are transmitted to a server computer using CDMA wireless connection by gateway system. The D/B of server computer are constructed automatically and monitored the project web site. The resulting system can be used for scour monitoring, environment monitoring and the other monitoring purposes such as a river flow monitoring system.

  • PDF

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.

Design of a Multi-Protocol Gateway System Based on Low Power Wireless Communications (저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계)

  • Hong, Sung-IL;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.10
    • /
    • pp.2006-2013
    • /
    • 2015
  • In this paper we propose a multi-protocol gateway system based on low power wireless communications. The proposed multi-protocol gateway system was designed to allow real-time monitoring and control of the on-site situation through wired and wireless networks by gathering information for streetlight power control and environmental monitoring. The sensing data using multi-sensors with composite processing that selectively used wired or wireless communication (e.g., CDMA, Ethernet (TCP/IP), GPS, etc.) were designed to act as intermediaries that transmitted to the main server through ZigBee. Inaddition, they were designed by separating a CPU board and baseboard to ensure low maintenance cost and ease of hardware replacement. The proposed multi-protocol gateway system's power, impact, continuous operation stability, and immunity test results obtained a normal operation success rate of over 95% and normal continuous operation results. Moreover, in the voltage drop test, instantaneous immunity test, and conductive RF electromagnetic field immunity test, it obtained an average rating result of "A".

Adoption of Wireless Near Field Communication Method in the Discharge Measurements using Microwave Water Surface Current Meter (전자파표면유속계를 이용한 유량측정시 근거리 통신의 적용)

  • Kim, Young-Sung;Yang, Jae-Rheen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1784-1788
    • /
    • 2008
  • 전자파표면유속계는 여러 측정지점을 가능한 신속하게 이동하면서 홍수시 유속을 측정하는데 그 목적이 있다. 또한 홍수시 유속은 시간대 별로 급격히 변하는 속성을 가지고 있으므로 유량측정 지점의 유량을 실시간으로 획득하기 위해서는 현장 측정에서 측정한 유량데이터가 실시간으로 집계 되어야한다. 현재의 시스템은 측정 정보를 실시간으로 전송하기 위하여 현장 측정자에게 PDA가 보급되어 있으며 CDMA망을 통해서 유량 측정을 위한 각종 정보 및 측정결과를 실시간 전송하도록 되어있다. 그러나 전자파표면유속계를 비롯한 각종 유속계가 PDA와 무선으로 통신을 할 수 있게 되어있지 않기 때문에 열악한 여건의 현장에서 측정한 데이터를 야장에 수기로 기록한 후 이를 다시 PDA에 수동으로 입력시켜야하는 불편함이 있다. 전자파표면 유속계를 제외한 다른 측정 장비는 제조회사가 수자원공사와 독립적인 업체이므로 통신 접속을 하기위한 특정 인터페이스를 알아내기가 어려운 실정이다. 그러나 전자파표면유속계는 수자원공사에서 개발한 장비로서 핵심기술을 수자원공사에서 보유하고 있으므로 PDA와 통신을 가능하게 하는 장치의 개발이 가능하다. 이에 이러한 불편한 문제점을 개선하여 현장에서 홍수 유량 측정시 작업자들의 편이성을 증대시키고자 전자파표면유속계와 PDA간에 근거리통신기법을 적용하였다. 이를 위하여 Bluetooth, UWB(Ultra-Wide Band, 초광대역통신), Zigbee 등 적용가능한 근거리 통신기법을 조사하였다. 그 결과 Zigbee가 소비전력이 적어 현장에서 홍수유량측정에 이용되는 전자파표면유속계에 적용성이 가장 뛰어난 것으로 나타났다. 무선통신 모듈과 연동되는 전자파표면유속계는 이동식을 기준으로 적용하였으며 기존 신호처리부에 무선통신 모듈을 장착할 수 있는 구조로 설계하였다. 장착 방식은 기존 이동식 유속계의 신호처리부의 RS-232 포트에 무선통신 모듈을 장착하면 사용할 수 있는 구조로 되어있다. 신호처리부 RS-232 포트는 현재까지는 측정한 유속값을 PC로 전송받는 용도로 활용되었으나 무선모듈 장착 시에는 무선통신 할 수 있는 이중화 구조를 채택하였다. 두 가지 방식에 대한 통신구별은 초기에 송수신하는 데이터에 따라 구별되도록 하였다. 신호처리부에서 무선통신 추가에 따른 운용 방식은 별도의 수자원공사 모드를 추가하여 운용하도록 수정하였다. 유속 측정 시에는 무선통신 모듈을 제거한 상태에서 측정한 후, 측정한 데이터를 PDA로 전송할 때 아를 부착하여 사용할 수 있는 구조를 갖도록 제작하였다. 이러한 방식을 적용시킨 이유는 기존에 보급된 유속계에 무선모듈을 장착한 후, 신호처리부 운용 프로그램을 업그레이드하면 바로 사용할 수 있도록 하기 위함이다.

  • PDF

Development of a Prototype System for Slope Failure Monitoring Based on USN Technology (USN 기술을 이용한 사면붕괴모니터링 시범시스템 개발)

  • Han, Jae-Goo;Kim, Kyoon-Tai
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.316-321
    • /
    • 2007
  • The casualties due to slope failures such as landslide, rock fall, debris flow etc. are about 24% in total casualties caused by natural disasters for the last 10 years. And these slope failures are focused in the season in which typhoon and torrential rain take place. Not much attention, however, have been put into landslide mitigation research. Meanwhile, USN(Ubiquitous Sensor Network) forms the self-organization network, and transfers the information among sensor nodes that have computing technology ability. Accordingly, USN is embossed a social point technology. The objective of this paper is to develop a prototype system for slope failure monitoring using USN technology. For this we develop module that collects and change slope movement data measured by two tiltermeter and a tension wire, store transferred data in database. Also we develop application program that can easily analyze the data. We apply the prototype system to a test site at KICT for testing and analyzing the system's performance.

  • PDF

Real-Time Construction Resource Monitoring using RFID/USN Inter-working System (RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템)

  • Ryu, Jeoung-Pil;Kim, Hyoung-Kwan;Kim, Chang-Yoon;Kim, Chang-Wan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.90-94
    • /
    • 2007
  • Location tracking automation of resources in construction industry is one of the most important procedures to improve construction project performance and reduce the period of construction. Recently, location tracking technologies have proven to be effective in tracking construction materials and equipment in real time through the instrumentality of RFID (Radio Frequency Identification). By using wireless communication and inter-working system between RFID and USN, it is possible that construction engineers receive the location information of construction resources without additional efforts that move the RFID reader to read tags periodically. In the inter-working system, RFID reader delivers the acquired materials information to sensor node which is connected by serial interface. Then sensor node transmits the received data to the data aggregation terminal that is a sink node. The data aggregation terminal can transmit collected data to construction manager who is out of construction site using infrastructure such as CDMA(Code Division Multiple Access) network. The combination model of the two system and field test scenarios are presented in this paper.

  • PDF