• Title/Summary/Keyword: wire model

Search Result 656, Processing Time 0.023 seconds

A Study on Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system (불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구)

  • 오재훈;한윤석;김영석;원충연;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.386-393
    • /
    • 2001
  • A series active power filter compensating current harmonics and unbalanced source voltages in a 3phase-3wire power system is presented. The system is composed of series active power filter and shunt passive filters that are tuned at 5th and 7th harmonics. The proposed series active power filter improves harmonic compensation characteristics of the shunt passive filters, reduces source side harmonic currents and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are Presented to demonstrate and confirm its validity.

  • PDF

A Basic Study on Plastic Suspension System for Automotive Seat under Consideration of Body Pressure Distribution (체압 분포를 고려한 자동차 시트용 플라스틱 서스펜션에 대한 기초적 연구)

  • Park, Dae-Min;Kim, Key-Sun;Choi, Doo-Seuk;Kim, Sei-Whan;Park, Won-Sik;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4751-4755
    • /
    • 2011
  • This study investigates the plastic suspension assembly which is installed on inside of vehicle seat and support passenger's back to supply the comfortable ride performance. It aims to develop the structural design in order to support driver's back uniformly and assemble seat back frame with plastic suspension effectively. The part of suspension is designed by considering the body pressure distribution of driver and it has the same size as the practical model on simulation analysis. It is confirmed that the analysis result of plastic suspension approaches the practical measured values and the better body pressure distribution can be obtained as compared with the existing wire type.

An Analysis on the Evolutionary Characteristics of Ubiquitous City through Evolutionary Map of Ubiquitous City (유시티 진화 지도를 통한 유시티 진화 특성 분석)

  • JO, Sung-Soo;LEE, Sang-Ho;LEEM, Youn-Taik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.18 no.2
    • /
    • pp.75-91
    • /
    • 2015
  • This study aims to analyse the U-City characteristics through the U-City historical mapping. The U-City characteristics were analysed by building the U-City historical map in terms of STIM model which consists of service, technology, infrastructure and management. The data for analysis is the National Informatization White Paper published by the NIA (National Information Society Agency) from 2002 to 2013. As a result, first, the U-City service were evolved from administration informatization, enterprise informatization, administration/living informatization and administration/space/private informatization through the intelligence facilities and space. Second, the U-City technology were changed through wire network, sensor/network, processing/super-highway network, convergence of network/security. Third, the U-City infrastructure have had evolutionary process such as wire computer network, wire/wireless network, intellectualization facility and intelligent facility space. Forth, the U-City management were carried out with making the unit network/infrastructure management, information connection/operating management and information integration/participation management. Therefore, the history of U-City has been making rapid development in government computerization, computer oriented society, information city and ubiquitous city.

3-dimensional finite element analysis of maxillary molar distalization using R-jig with TADs (TADs와 R-jig를 이용한 상악 구치 원심 이동에 관한 3차원 유한요소 분석)

  • Tark, Myung-Hyun;Lee, Keunyoung;Cho, Jin-Woo;Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.265-277
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the differences of displacement pattern depending on type of sliding jig and application method during maxillary molar distalization with temporary anchorage devices (TADs). Materials and Methods: Maxilla with normal tooth size and arch shape was selected to create a 3-dimensional finite element model, which included the bracket, orthodontic main archwire, removable sliding jig (R-jig). The orthodontic mini-implant anchorage was set 8 mm superiorly from main archwire, buccally between the second premolar and first molar. The base experimental design was Condition 1, which was composed $0.019{\times}0.025$ inch stainless steel (SS) of wire size of R-jig, 200 gm force, un-tied state. And the other designs varied to wire size of R-jig, magnitude of force. The results are as follows. Results: As the wire size of R-jig was increased, the deformation of R-jig was decreased. However, the displacement of second molar wasn't different each other. As the force to second molar was increased, the more displacement of second molar was observed, and the more distal tipping movement, vetical displacement was observed. Conclusion: R-jig can get distal teeth movement in orthodontic treatment without side effects.

Change in tooth length and angulation on panoramic radiographs taken at different labiolingual and buccolingual inclinations (치아의 순(협)설 경사도 변화에 따라 파노라마 방사선 사진에 나타난 치아 길이 및 각도 변화)

  • Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Jae-Duck;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.114-124
    • /
    • 2007
  • Objective: The purpose of this study was to examine how the mesio-distal angulation and the length of each tooth changes on panoramic radiograph at different bucco-lingual inclinations. Methods: After constructing an acrylic model based on the mean arch of 30 adults with normal occlusion, the wire was placed in the center of the teeth on the acrylic model. First, the wire was implanted in normal angulation and inclination and a panoramic radiograph taken. After changing the inclination from $I-5^{\circ}\;to\;I+15^{\circ}\;by\;5^{\circ}$, a panoramic radiograph was taken again and the mesio-distal angle and wire length on the panoramic radiograph were assessed. Results: When the wire was implanted at the normal angulation and inclination, the length measured in the panoramic radiograph was magnified $111{\sim}117%$ from the original length in the anterior region and $121{\sim}125%$ in the posterior region. Only the central and lateral incisors showed significant length differences when the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$ at fixed angulation. When the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$, the angulation of most teeth on panoramic radiograph appeared to be more disto-angulated than in reality, and the lateral incisor and canine showed the largest difference. Only $l-15^{\circ}\;to\;I+15^{\circ}$ groups of premolars and $I+15^{\circ}$ group of molars showed more mesio-angulation than in reality. As the labio(bucco)lingual inclination of all teeth were decreased, tooth angulation in the panoramic radiograph appeared to be more disto-angulated. Conclusion: The labio-liugual inclination of teeth should be considered because it affects panoramic image of teeth, such as length of incisors and angulation of other teeth.

Three dimensional analysis of tooth movement using different sizes of NiTi wire on NiTi scissors-bite corrector (NiTi scissors-bite corrector의 와이어 굵기에 따른 3차원적 치아 이동 양상)

  • Jeon, Hyun-Ju;Park, Sun-Hyung;Jung, Sang-Hyuk;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • Objective: The purpose of this study was to compare the difference in three dimensional tooth movement using three different wire sizes($0.018{\times}0.025-in,\;0.016{\times}0.022-in$ 0.016-in) on a NiTi scissors-bite corrector. Methods: Computed tomography(CT) images of the experimental model before and after tooth movement were taken and reconstructed into three dimensional models for superimposition. The direction and the amount of tooth movement were measured and analyzed statistically. Results: The lingual and intrusive movements of the crown of the maxillary second molar were increased as the size of the NiTi wire increased. The roots of the maxillary second metals moved buccally except for the 0.016-in group. The intrusive movement of the roots of the maxillary second molars was increased as the size of the NiTi wire increased. Due to the use of orthodontic mini-implants, anchorage loss was under 0.2 mm on average. Conclusions: The $0.018{\times}0.025-in$ NiTi wire was most effective in lingual and intrusive movement of the maxillary second molar which was in scissors-bite position. Indirect skeletal anchorage with a single orthodontic mini-implant was rigid enough to prevent anchorage loss.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

Performance Test and Numerical Model Development of Restoring Viscous Damper for X-type Damper System (X형 감쇠시스템을 위한 복원성 점성 감쇠기 성능 실험 및 수치모형 개발)

  • Kim, David;Park, Jangho;Ok, Seung-Yong;Park, Wonsuk
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.52-57
    • /
    • 2016
  • In this study, a restoring viscous damper is introduced for X-type damper system which is designed for the seismic response control of large spatial structures. A nonlinear numerical model for its behavior is developed using the result of dynamic loading tests. The X-type damper system is composed of restoring viscous dampers and connecting devices such as adjustable wire bracing, where the damping capacity of the system is controllable by changing the number of the dampers. The restoring viscous damper is devised to exert main damping force in tension direction, which is effective to prevent the buckling of bracing subjected to compressive axial force. To evaluate the performance of the proposed damper, dynamic cyclic loading tests are performed by using manufactured dampers at full scale. In order to construct the numerical model of the damper system, its model parameters are first identified using a nonlinear curve fitting method with the test data. The numerical simulations are then performed to validate the accuracy of the numerical model in comparison with the experimental test results. It is expected that the proposed system is effectively applicable to various building structures for seismic performance enhancement.

Developmental Disability Animal Model Based on Neonatal Lipopolysaccharide with Altered 5-HT Function

  • Kim, Jae-Goo;Kim, Min-Soo;Lee, Se-Oul;Kim, Gun-Tae;Lee, Jong-Doo;Kim, Dong-Goo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.11 no.3
    • /
    • pp.113-119
    • /
    • 2007
  • Developmental disability shows life-long behavioral abnormality with no significant physical malformation. This study was undertaken to develop an animal model for developmental disability by using two-factor approach. Lipopolysaccharide (LPS), a bacterial toxin, and NAN-190, a $5-HT_{1A}$ receptor antagonist, were administered to Sprague-Dawley rats on postnatal day (PND) 5 to induce inflammation and an altered 5-HT system, respectively. Long-term alteration of behavior occurred in the drug-treated groups. The LPS-treated group showed impaired motor coordination in the Rota-rod test. The LPS- treated or both LPS and NAN-190-treated groups showed impaired fore-paw muscle power in the wire maneuver test. These groups also showed decreased white matter volume and increased serotonergic fibers. The LPS and NAN-190-treated group also exhibited neurologic deficit in the placing reaction test and impaired equilibrium function in the tilt table test. The results showed that a variety of altered behaviors can be generated by two factor model, and suggested that combination of important etiologic factors and possible underlying defects is a promising strategy of establishing an animal model for developmental disabilities.