• Title/Summary/Keyword: windows & doors

Search Result 155, Processing Time 0.026 seconds

Improvement of Bill of Quantities of Door and Window Work for BIM-based Cost Estimation (BIM 기반 견적을 위한 창호공사 내역 작성체계 개선 방안)

  • Kim, Mi-Hyeon;Jo, Chan-Won;Yun, Seok-Heon
    • Journal of KIBIM
    • /
    • v.10 no.2
    • /
    • pp.12-20
    • /
    • 2020
  • Recently, interest in BIM technology has been growing in the domestic construction market as the number of construction projects requiring the application of BIM technology has increased. The use of BIM allows the use of various visualization functions through 3D models as well as drawing interference review, quantity calculation and integrated management of information. In particular, estimates of construction costs based on BIM can increase work efficiency by reducing the burden of calculating construction costs and managing them. In order to increase the efficiency of BIM-based cost estimates, it is necessary to improve the correlation between the BoQ(Bill of Quantity) information and the BIM model. For this purpose, the ratio of the amount and item to the detailed construction of the current BoQ was analyzed, especially the problem of the calculation of construction cost in the window work in this study. In addition, we would like to suggest a method for systematically linking the BoQ information with the BIM model by improving the BoQ information structure of the window work. It is expected that this will increase the efficiency of the quantity calculation and analysis work of construction cost of window work. In addition, it is expected that this method will help to analyze and predict changes in construction cost of windows and doors by facility characteristics and type.

Evaluation for Argon gas-filled Insulating glass units (아르곤가스 주입 단열 복층유리 내구성 평가)

  • Kim, Kyung-Nam;Jung, Jin-Young;Bae, Ki-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.128-131
    • /
    • 2013
  • Energy losses through windows and doors are big problems in the construction industry. For glass only, it has takes the largest portion of mass from window assembly and it responsible for 24 ~ 45% of energy loss from total building energy loss. Insulating glass unit should maintain their basic functions during their working life in order to contribute positively for global warming issue. There have been many research works for improving insulating glass unit durability. But it is not easy job to fulfill the requirements because insulating glass units composed of many components. So, overall it is required to have right qualify control procedures starting from material selection to fabrication, shipping and installation to the customer site. In this report, we have reviewed the durability of insulating glass unit made from different grades of sealing materials based on globally accepted industry codes such as EN1279. ASTM E 2190 and Locally available code. KS L 2003. The result showed that there is a relationship between the mechanical properties of insulating glass 2nd sealant and the durability of the units.

  • PDF

A Study on the Characteristics and Periodical Changes of Meoreum - Focused on Byeoldang (Annexe) and Pavilion Architecture - (머름의 특성과 변천에 관한 연구 - 별당과 정자건축을 중심으로 -)

  • Park, Il-Chan;Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.20 no.2
    • /
    • pp.7-22
    • /
    • 2011
  • This study primarily aims to illuminate the characteristics of $Meoreum$ in Korean traditional fitting system according to the respective types and its periodical changes. Using the research findings as a chronological indicator by which to estimate the construction date of the building is the secondary purpose. In this study 42 of $Byeoldang$ and pavilion architecture remaining in $Yeongnam$ district were examined through the field surveys and methods of documentary research. The research results are as follows. First, $Meoreum$, which is located below the windows or doors, provides protection against the outer wind and has the function to prevent some warm air of the room from flowing outside. Second, $Meoreum$ was recorded as $Yoeum$(了音), $Woneum$(遠音), and $Maleum$(末音) in $Yeong-geon-ui-gwe$(營建儀軌) of Joseon period. While $Yoeum$(了音) was used in $Yeong-geon-ui-gwe$(營建儀軌) of 1776 and 1856, $Woneum$(遠音) had been also used continuously since the year of 1800. The word, $Maleum$(末音) can be seen in $Lim-won-gyeong-je-ji$(林園經濟志), published in 1827. $Woneum$(遠音) and $Maleum$(末音) seem to be the $Yi-du$(吏讀) types of expression of $Meoreum$ which is being extensively used now. Third, the kinds of $Meoreum$ can be classified as $TohMeoreum$, $TongMeoreum$, $TongpanMeoreum$, and $JjaneunMeoreum$. $TongMeoreum$ and $TohMeoreum$ were mostly used at the front part of $Ondol-rooms$, the backside of main floor called $Daechung$(大廳), and at the space between $Daechung$ and rooms in the Pavilions and $Byeoldangs$(Annexes) that had been built in the early Joseon dynasty. $TohMeoreum$ was usually used at the bottom parts of windows between $Daechung$ and $Ondol-rooms$. $TongpanMeoreum$ was mainly used in the mid-Joseon period and relatively high height was the distinctive feature of $Meoreum$ at that time. $Jjaneun$ $Meoreum$, used mainly in the late Joseon dynasty, has become lower and lower gradually in height since 19th century, so people could enter the room through the windows(fittings). Such changes in $Meoreums$ types has brought about the flow of human traffic directly from $Toenmaru$, narrow wooden porch running along the outside of a room to $Ondol-rooms$.

Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings (초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석)

  • Shin, Sang Wook;Ryu, Jong Woo;Jeong, Hee Woong;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.

Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements (현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사)

  • Ryu, Da-Jung;Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.329-337
    • /
    • 2017
  • In USA and UK, the standards of both reverberation time and background noise level have been established for the appropriate aural environment in classrooms. In order to realize this, guidelines for architectural planning and interior finishing have been also suggested. However, in Korea, there has hardly been any guidelines for satisfying background noise criteria and investigation about sound insulation performance of current walls of classrooms. The present study investigates the structure of outer wall and walls between classrooms of two middle schools in order to analyze the sound insulation performance against both exterior and interior noises. Acoustic parameters including transmission loss, standardized sound level difference, and signal to noise ratio have been measured and analyzed for sound insulation performance of walls and flanking noises. As a result, concerning the walls in between classrooms, it was found that walls of dry construction have greater sound insulation performance rather than the walls of wet construction especially in mid and high frequency bands. Also, It was revealed that thermopane, insulated pair glass, of outer walls, has greater sound insulation performance than the double window consisted of two single pane glass. Regarding flanking noises, the standards were exceeded when all windows, or windows and doors front onto corridor were opened. It denotes that students could be disturbed with the sound transmission by the interior noises.

Present Condition of Indoor Thermal and Air Environment by Air-conditioning in School Classrooms (학교교실의 냉방시 실내열.공기 환경 실태)

  • Choi, Yoon-Jung;Kim, Hye-Kyeong;Hwang, Jin-A;Lee, Seon-A;Jeong, Youn-Hong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.291-296
    • /
    • 2006
  • The purpose of this study were to make clear the present condition of indoor thermal and air environment by air-conditioning in school classrooms and to analyze the relation of the living conditions with indoor environment. The measurements on physical elements and observations on living conditions were carried out in 6 classrooms of 3 middle or high schools. Measuring elements were indoor temperature, relative humidity, $PM_{10}$ and $CO_2$ concentration. As results, the averages of indoor temperature each classrooms were 24.9${\sim}$26.6 . Most of classrooms were lower than the Maintenance standard(26${\sim}$28 ) of School Health Law. The means of relative humidity were 51.3${\sim}$72%, all classrooms were ranged within the standard(30${\sim}$80%). The means of $PM_{10}$ concentration were 3.5${\sim}$23.1 ${\mu}g/m^3$, all classrooms were kept within the standard(100 ${\mu}g/m^3$). The means of $CO_2$ concentration were 1218.7${\sim}$4705.4 ppm, all classrooms were exceed the standard(1,000ppm). The results of analysis on relations of living conditions with the physical elements are as follow; the air conditioner set of temperature, windows and doors opening elapsed time, the number of students in classrooms and activities of students had certain effect on indoor environment.

  • PDF

Study on the categorization of modus operandi and tools used in domestic burglary (건축물 침입에 이용되는 침입수법 및 도구의 유형화 연구)

  • Park, Hyeon-Ho;Cho, Joon-Tag
    • Korean Security Journal
    • /
    • no.40
    • /
    • pp.57-86
    • /
    • 2014
  • As the revision of Building Code including applying crime prevention design to buildings passed recently and target hardening ought to be evidence-based, we studied the Modus Operandi (MO) and intrusion tools of domestic burglary to earn basic data for improvement of crime prevention hardware in the future. To be specific, we reviewed related academic literature and police official statistics of domestic burglary critically and interviewed detectives in charge of burglary to specify and categorize MO and tools. We can derive some implications from research findings, including improvement of the statistical system for the MO of burglary, active sharing of the MO of burglary among the criminal justice agencies and related industries and experts. Also, crime prevention advice and education for the local residents focused on MO of burglary can be recommended. Based on this research, to enhance the level of community safety significantly, performance tests of crime prevention hardware such as security doors and windows etc. and the study on related certification system should be vitalized.

  • PDF

Accuracy Comparison Between Image-based 3D Reconstruction Technique and Terrestrial LiDAR for As-built BIM of Outdoor Structures

  • Lee, Jisang;Hong, Seunghwan;Cho, Hanjin;Park, Ilsuk;Cho, Hyoungsig;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.6
    • /
    • pp.557-567
    • /
    • 2015
  • With the increasing demands of 3D spatial information in urban environment, the importance of point clouds generation techniques have been increased. In particular, for as-built BIM, the point clouds with the high accuracy and density is required to describe the detail information of building components. Since the terrestrial LiDAR has high performance in terms of accuracy and point density, it has been widely used for as-built 3D modelling. However, the high cost of devices is obstacle for general uses, and the image-based 3D reconstruction technique is being a new attraction as an alternative solution. This paper compares the image-based 3D reconstruction technique and the terrestrial LiDAR in point of establishing the as-built BIM of outdoor structures. The point clouds generated from the image-based 3D reconstruction technique could roughly present the 3D shape of a building, but could not precisely express detail information, such as windows, doors and a roof of building. There were 13.2~28.9 cm of RMSE between the terrestrial LiDAR scanning data and the point clouds, which generated from smartphone and DSLR camera images. In conclusion, the results demonstrate that the image-based 3D reconstruction can be used in drawing building footprint and wireframe, and the terrestrial LiDAR is suitable for detail 3D outdoor modeling.

Documentation of the History of Ok-Cheon Catholic Church by standardized 2D CAD and 3D Digital Modeling (표준화된 2D CAD와 3D Digital Modeling을 이용한 옥천천주교회의 연혁 기록)

  • Kim, Myung-Sun;Choi, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.523-528
    • /
    • 2011
  • Ok-Cheon catholic church has been changed 4 times since it's first construction in 1955. Prior three changes were small ones of windows, doors, roof finish etc. but the last alteration was the extension of it's plan from 一 shape to long cross shape and along with it the size, structure and form of it changed. This history of the church has not been recorded in drawing but only in text with indistinct features not documented. This study makes a new 2D CAD files using layers matched the changes and 3D digital models, these have not only present information but also change informations of the church. They are useful data for effective management, conservation restoration or possible reuse of it.

An Indoor Propagation Modeling that can Analyze a Fading Characteristic (페이딩 분석이 가능한 실내 전파 모델링)

  • Seok, Woo-Chan;Kim, Jin-Woong;Yoon, Young-Joong;Seok, Jae-Ho;Lim, Jae-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1B
    • /
    • pp.114-124
    • /
    • 2002
  • In this paper, we proposed the image-based 3D ray tracing indoor propagation model using a patch scattering model for fading analysis of indoor propagation environments. An image-based 3D ray tracing technique is mainly used, which allows the rapid generation of the complex channel impulse response for any given location and polarization of transmitter and receiver. Due to the site specific nature of indoor environment, we took into account the location and the electrical properties of individual walls and objects such as windows, doors and plaster board in our propagation model. Besides, the 3D radiation beam-patterns and polarizations of arbitrary antennas were considered, and using patch scattering model we can consider the change of the polarization due to the scattering from the various indoor objects, like desks, chairs and etc. the are almost impossible to be modeled with the basic image-based ray tracing method. The model will predict the impulse response, the rms delay spread, the fading characteristics of the channel and performances of the polarization diversity schemes.