• Title/Summary/Keyword: window opening technique

Search Result 12, Processing Time 0.027 seconds

Comparison of implant survival rate by sinus lifting technique in implantation with sinus lift (상악동 거상술을 동반한 임플란트 식립 시에 거상술 방법에 따른 임플란트 생존율의 비교)

  • Park, Kwang-Su;Hong, Ki-Seok;Chung, Chin-Hyung;Lim, Sung-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.445-452
    • /
    • 2008
  • Purpose: The purpose of this study was comparison of survival rate of implant as two sinus elevation techniques and when window opening procedure had done it was comparison of survival rate of implant between the procedure of implantation after 6 month of sinus elevation to allow healing period and that of implantation with sinus elevation simultaneously. Material and Methods: All 79 of patients treated at DanKook University Dental Hospital Dept. of Periodontics for 164 implantation of maxillary posterior edentulous area with sinus elevation. Sinus elevation technique was divided of the technique : Osteotome technique and window opening technique. Result: 14 implants among 96 implants was failed implants of using osteotome for sinus elevation whereas one implant of 68 implants was failed of using window opening technique. Conclusion: Window opening technique had higher survival rate than osteotome technique. In case of window opening, there was no significant difference of immediate implantation and delayed implantation.

Clinical evaluation of $Br{\aa}nemark$ Ti-Unite implant and ITI SLA implant in the post maxillary area with sinus elevation technique. (상악동 거상술을 이용하여 구치부에 식립된 $Br{\aa}nemark$ Ti-Unite와 ITI SLA 임플란트의 임상적 평가)

  • Hong, Seong-Bae;Chai, Gyung-Joon;Jung, UI-Won;Kim, Chang-Sung;Chim, Joon-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.813-822
    • /
    • 2005
  • The predictable outcome of implant placement in the atrophic maxilla with sinus floor elevation procedure(osteotome sinus floor elevation technique and window opening technique) is well documented. Aim of this study was to evaluate the efficacy of $Br{\aa}nemark$ Ti-Unite implant system and ITI SLA implant system placed in the atrophic posterior maxilla with sinus floor elevation procedure. Eighty patients received placement of $Br{\aa}nemark$ Ti-Unite implants(195 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(153 osteotome sinus floor elevation technique and 42 window opening procedure). Fifty patients received placement of ITI SLA implants(83 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(77 osteotome sinus floor elevation technique and 6 window opening procedure). Chart review were taken from each patient. The total failed implants were seven and the total implant survival rate was 96.4% in $Br{\aa}nemark$ Ti-Unite system. The total failed implants were one and the total implant survival rate was 98.8% in ITI SLA system. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in $Br{\aa}nemark$ Ti-Unite system. The implant survival rate with osteotome technique was 98.7% and 100% with window opening. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in ITI SLA system. The results of this evaluation show that the placement of $Br{\aa}nemark$ Ti-Unite system as well as ITI SLA system is a reasonable treatment option for patients with the atrophic posterior maxillary area.

Safety and feasibility of opening window fistulotomy as a new precutting technique for primary biliary access in endoscopic retrograde cholangiopancreatography

  • Yasuhiro Kuraishi;Kazuo Hara;Shin Haba;Takamichi Kuwahara;Nozomi Okuno;Takafumi Yanaidani;Sho Ishikawa;Tsukasa Yasuda;Masanori Yamada;Nobumasa Mizuno
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.490-498
    • /
    • 2023
  • Background/Aims: Post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is the most common and serious complication of endoscopic retrograde cholangiopancreatography. To prevent this event, a unique precutting method, termed opening window fistulotomy, was performed in patients with a large infundibulum as the primary procedure for biliary cannulation, whereby a suprapapillary laid-down H-shaped incision was made without touching the orifice. This study aimed to assess the safety and feasibility of this novel technique. Methods: One hundred and ten patients were prospectively enrolled in this study. Patients with a papillary roof size ≥10 mm underwent opening window fistulotomy for primary biliary access. In addition, the incidence of complications and success rate of biliary cannulation were evaluated. Results: The median size of the papillary roof was 6 mm (range, 3-20 mm). Opening window fistulotomy was performed in 30 patients (27.3%), none of whom displayed PEP. Duodenal perforation was recorded in one patient (3.3%), which was resolved by conservative treatment. The cannulation rate was high (96.7%, 29/30 patients). The median duration of biliary access was 8 minutes (range, 3-15 minutes). Conclusions: Opening window fistulotomy demonstrated its feasibility for primary biliary access by achieving great safety with no PEP complications and a high success rate for biliary cannulation.

Optimal Loudspeaker Positions of an Active Noise Control System with an Opening in an Enclosure (개구부를 가지는 실내의 능동소음제어시스템에서의 최적스피커 위치)

  • 백광현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.788-791
    • /
    • 2003
  • Optimal loudspeaker positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in the enclosure. An optimization technique called simulated annealing algorithm is used to find a set of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wail. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions we identified and compared. When a small number of loudspeakers are used, loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns Un the optimal positions.

  • PDF

Optimal Transducer Positions of an Active Noise Control System with an Opening in an Enclosure (개구부를 가지는 실내의 능동소음제어시스템의 최적 트랜스듀서 위치)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Optimal transducer positions are important as much as the control algorithms and hardware performance in the active noise control system. This study is similar to the past researches on the optimal transducer locations but with a far field noise source having a plane wave characteristic and the noise coming through an opening such as a window in an enclosure. Optimization techniques are used to find sets of optimal loudspeaker positions from a larger possible loudspeaker positions. Loudspeakers are placed on the surface of opening at the wall and inside of the enclosure. Using the measured acoustic transfer impedances and numerical simulations with the optimization technique, optimal positions are identified and compared. When a small number of loudspeakers are used. loudspeaker positions on the opening near the center seems to be the best place, but when a larger number of loudspeakers are used it was difficult to find simple patterns in the optimal positions. With the optimally positioned loudspeakers, optimal microphone positions are also studied.

Rehabilitation of a patient with atrophic ridges using gothic arch tracing and nonpressure impression: a case report (심하게 흡수된 치조제를 가진 환자에서 고딕 아치 기록과 무압 인상을 이용한 총의치 수복: 증례보고)

  • Lee, Shin-Yeop;Yu, Jung-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.232-238
    • /
    • 2018
  • Flabby ridges adversely affect the stability of complete dentures. For the management it is suggested that soft tissues reconditioned before making definitive dentures, and modified impression techniques used for the flabby ridges. Also, correct record of centric relation is important in complete dentures. This case of 67-year-old edentulous female patient had atrophied ridges on the mandible and the flabby ridge on the maxilla. Treatment dentures were fabricated using gothic arch tracing method and tissue conditioner. Definitive dentures were made using window opening impression technique, the gothic arch tracing method, and lingualized occlusion. The patient was satisfied with the function and esthetic quality of the new prostheses.

Temperature Control of Greenhouse Using Ventilation Window Adjustments by a Fuzzy Algorithm (퍼지제어에 의한 자연환기온실의 온도제어)

  • 정태상;민영봉;문경규
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.42-49
    • /
    • 2001
  • This study was carried out to develop a fuzzy control technique of ventilation window for controlling a temperature in a greenhouse. To reduce the fuzzy variables, the inside air temperature shop was taken as one of fuzzy variables, because the inside air temperature variation of a greenhouse by ventilation at the same window aperture is affected by difference between inside and outside air temperature, outside wind speed and the wind direction. Therefore, the antecedent variables for fuzzy algorithm were used the control error and its slop, which was same value as the inside air temperature slop during the control period, and the conclusion variable was used the window aperture opening rate. Through the basic and applicative control experiment with the control period of 3 minutes the optimum ranges of fuzzy variables were decided. The control error and its slop were taken as 3 and 1.5 times compared with target error in steady state, and the window opening rate were taken as 30% of full size of the window aperture. To evaluate the developed fuzzy algorithm in which the optimized 19 rules of fuzzy production were used, the performances of fuzzy control and PID control were compared. The temperature control errors by the fuzzy control and PID control were lower than 1.3$^{\circ}C$ and 2.2$^{\circ}C$ respectively. The accumulated operating size of the window, the number of operating and the number of inverse operating for the fuzzy control were 0.4 times, 0.5 times and 0.3 times of those compared with the PID control. Therefore, the fuzzy control can operating the window more smooth and reduce the operating energy by 1/2 times of PID control.

  • PDF

Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip (미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명)

  • Lee, Jaewoo;Kwak, Tae Joon;Yoon, Dae Sung;Lee, Sang Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.

Combined Effects of Physical Evidence and Functional Service at Bulgogi Restaurants on Customers' Store Image and Purchase Behaviors: Application of Video Scenario Technique

  • Hwang, Daye;Chang, Hyeja
    • Journal of the Korean Society of Food Culture
    • /
    • v.35 no.2
    • /
    • pp.181-192
    • /
    • 2020
  • This study aimed to identify whether or not four service situations varying according to positive and negative combinations of physical evidence and functional service influence store image and purchase behavioral intentions of customers at bulgogi restaurants. The video-scenario technique was used for the study. Data were analyzed with the SPSS (Window 19.0) package using frequency analysis, one-way ANOVA, 2 by 2 factorial ANOVA, exploratory factor analysis, and multiple regression analysis to confirm the hypotheses. The combined effect of functional service and physical evidence influenced store image and purchase intention. In terms of seperate effect of physical evidence and functional service, the effect of employee service on store image was more powerful than that of physical evidence, even though the effect differed depending on the situation. Purchase intention was only influenced by functional service quality from employees under the four different scenarios. Thus, when opening a Korean restaurant, proper management of tangible evidence suitable to service, and the prices expected from local customers should be determined. Additionally, extremely high or low levels of physical evidence management should be avoided.

A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials

  • Hieu, Pham-Duong;Chung, Jin-Hyung;Yim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: The performance of implant surgery in the posterior maxilla often poses a challenge due to insufficient available bone. Sinus floor elevation was developed to increase the needed vertical height to overcome this problem. However, grafting materials used for the sinus lift technique eventually show resorption. The present study radiographically compared and evaluated the changes in height of the grafting materials after carrying out maxillary sinus elevation with a window opening procedure. This study also evaluated the difference between two xenogenic bone materials when being used for the sinus lifting procedure. Methods: Twenty-one patients were recruited for this study and underwent a sinus lift procedure. All sites were treated with either bovine bone (Bio-$Oss^{(R)}$) with platelet-rich plasma (PRP) or bovine bone (OCS-$B^{(R)}$)/PRP. A total of 69 implants were placed equally 6-8 months after the sinus lift. All sites were clinically and radiographically evaluated right after the implant surgery, 7-12 months, 13-24 months, and 25-48 months after their prosthetic loading. Results: Changes of implant length/bone length with time showed a statistically significant decreasing tendency (P<0.05). There was no significant change in the Bio-$Oss^{(R)}$ group (P>0.05). In contrast, the OCS-$B^{(R)}$ group showed a significant decrease with time (P<0.05). However, no significant difference was observed between the two groups (P>0.05). Conclusions: The results showed that there was significant reduction in comparison with data right after placement, after 7 to 12 months, 13 to 24 months, and over 25 months; however, reduction rates between each period have shown to be without significance. No significant difference in height change was observed between the Bio-$Oss^{(R)}$ and the OCS-$B^{(R)}$ groups.