• Title/Summary/Keyword: winding

Search Result 2,086, Processing Time 0.029 seconds

Auto-Diagnosis for Stator Winding Faults Using Distortion Ratio of Park's Vector Pattern (Park's 벡터 패턴의 왜곡률을 이용한 고정자 권선 고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Yang, Chul-Oh
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.160-163
    • /
    • 2008
  • In this paper, an auto-diagnosis method of the stator winding fault for small induction motor is suggested. 3-phase stator currents are sampled, filtered, and transformed with Park's vector transformation. After then Park's vector patterns are obtained. To detect the stator winding fault automatically, a distortion ratio is newly defined and compared with the one of healthy motor, and the threshold levels of distortion ratio are suggested. The 2-turn, 4-turn, 8-turn winding fault are tested with no load, 25%, 50%, 75%, and 100% rated load. The distortion ratio of the Park's vector patterns are increased as the increase of the faulted turns, but are same as the increase of the load.

10kVA High $T_c$ Superconducting Power Transformer with Double Pancake Winding (더블펜케익 권선형 10kVA 고온초전도 변압기)

  • Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.934-936
    • /
    • 2000
  • This paper presents the design of a double pancake winding type high $T_c$ superconducting power transformer In the design of the transformer. BSCCO-2223 tape was considered as the conductor. Double pan cake winding was adopted in order to easy the construction of the winding and to lessen the leakage reactance of the transformer. Numerical calculation was used to decide the arrangement of the double pan cake winding. Room temperature bore type cryostat has been constructed and its heat loss was estimation.

  • PDF

A Study on the Improvement of Dynamic Characteristics of the Motor Stator Coil Winding Machine (모터 고정자 코일 권선기의 동특성 개선 연구)

  • Kim, Dong-Sung;Kim, Kwang-Young;Ham, Sang-Yong;Son, Young-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1589-1596
    • /
    • 2003
  • In this paper, we performed the improvement study for the dynamic characteristics enhancement of the motor stator coil vertical winding machine. The dynamic characteristics improvement was done by means of the optimized design and the weight reduction of the flyer configuration, modified design of the servo control system for the flyer and the former actuation, and the development of jump timing digital circuit for the reduction of former jumping error. As the results, the maximum winding speed pattern of the developed machine was attained up to 3000rpm and also reduced the jumping error. In conclusion, domestic design technology for manufacturing the motor coil vertical winding machine was established through this study.

The Characteristics Analysis of a HTS Transformer (고온초전도변압기의 특성해석)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Yong-Uk;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.1
    • /
    • pp.27-31
    • /
    • 2000
  • This paper presents the performance evaluation of an HTS transformer. Numerical calculation by finite element method was used to evaluate the performance. BSCCO-2223 HTS tapes and double pancake winding were adopted in this design. Four double pancake windings were used in total. Among them two windings were connected in series for high voltage winding and two windings are connected in parallel for low voltage winding. Propertied of various type of the winding arrangement were examined. Characteristics of the transformer during the transient which was caused by sudden short were simulated. The current limiting effect, temperature rise and resistance growth of the superconducting winding were shown.

  • PDF

Graphical Presentation on Operational Principle of Pretective Relay According to Winding Type and Vector Group in Transformer (전력용 변압기에서 권선방식과 벡터그룹에 따른 보호계전기 동작원리의 그래픽 표현)

  • Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.226-233
    • /
    • 1999
  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical mode. It is developed using MATLAB for and educational purpose on engineer related in power system and protection in university and power utility including large factory.

  • PDF

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Characteristic Analysis of Synchronous Reluctance Motor Related to Slot Numbers and winding using Coupled Preisach Model & FEM (프라이자흐 모델이 결합된 유한요소법을 이용한 슬롯수, 권선법에 따른 동기형 릴럭턴스전동기의 특성해석)

  • Byun, Chan-Geun;Jang, Young-Jin;Lee, Mi-Jung;Lee, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1012-1014
    • /
    • 2003
  • This paper deals with the characteristic Analysis of synchronous reluctance motors (SynRMs) using coupled Preisach modeling & FEM. The focus of this paper is the characteristic Analysis relative to Inductances and losses on the basis of stator slot number, winding in SynRMs. The coupled Finite Elements Analysis (FEA) & Preisach model has been used to evaluate the nonlinear solution. Comparisons arc given with characteristics of normal distributed winding SynRM and those according to stator slot number, winding in concentrated winding SynRM, respectively.

  • PDF

A Surge Voltage Distribution Analysis of 2MVA Cast Resin Transformer Winding with FEM Simulation (FEM 시뮬레이션을 이용한 2MVA 몰드변압기 권선간 써지전압 분배 해석 기법 연구)

  • Jang, Hyeong-Taek;Shin, Pan-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.15-21
    • /
    • 2011
  • This paper presents an analyzing method of the capacitance of the power transformer for initial voltage distribution and insulation design. When a high incoming surge voltage is accidently occurred in windings of transformer, it does not distribute equally in the windings. This phenomenon makes electric field concentration and the insulating material could be break. Initial voltage distribute mostly depends on capacitances between winding to winding or winding to core in the transformer. If the C network can be structuralized into the equivalent circuit model and be calculated each capacitance element value by circuit analysis and FEM(Finite Element Method) simulation program, the transformer designer could know the place where the structure is to be modified or the insulation to be reinforced. This method quickly provides the data of the voltage distribution in each winding to the designer.

Analysis of Impulse Response of Power Transformer using Electric Equivalent Circuit (등가회로를 이용한 전력용 변압기의 과도응답 특성 해석)

  • Chang, Kyung-Woon;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.97-99
    • /
    • 1998
  • This paper presents a numerical study of the behavior of the transformer winding, when stressed by the standard impulse voltage. The mathematical model of the transformer takes several points into the account. Capacitance of not adjacent winding as well as adjacent winding, eddy current loss caused by self and mutual inductance given as the functions of frequency. Not like the previous approach where calculation of capacitance is performed, in average sense. In this paper, capacitance of both adjacent and not adjacent winding is calculated using the numerical approach(B.E.M.), so they can get the more accurate value of capacitance. Because of frequency dependency of inductance, numerical-laplace-transform technique is required. Finally, to validate this approach, a simple test winding is simulated.

  • PDF

Effect of Winding Coil Diameter on AC Insulation Breakdown Voltage of Polyamideimide/Nanosilica Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.231-234
    • /
    • 2016
  • The AC insulation breakdown voltage was investigated for seven types of winding coils made of polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires with various winding coil diameters of φ5, φ15 and φ25 mm. The winding coil was made of enameled wire with an enamel thickness of 30~50 μm, and the rectangular copper wire had a thickness of 0.77~ to 0.83 mm and width of 1.17~ to 1.23 mm, respectively. The insulation breakdown voltages of the original PAI coils with diameters of φ5, φ15 and φ25 mm were 7.30, 6.58, and 5.95 kV, respectively, and those values decreased as the winding coil diameter increased, regardless of the wire types.