• Title/Summary/Keyword: wind turbine control

Search Result 468, Processing Time 0.038 seconds

Offshore wind turbine installation vessel dynamic positioning capability analysis with considering installation structures

  • Daeseong, Lim;S.W., Kim;Jeong-Hyun, Yoon;Seo-ho, Lee
    • Ocean Systems Engineering
    • /
    • v.12 no.4
    • /
    • pp.461-477
    • /
    • 2022
  • Dynamic Positioning (DP) is a system that uses computer-controlled thrusters, propellers, and other propulsion devices to automatically maintain a vessel's position and heading. In this study, a wind turbine installation vessel with DP capabilities was proposed for use in mild environmental conditions in the Yellow Sea. The thruster arrangements of the vessel were analyzed in relation to wind and current loads, and it was found that a four-corner arrangement of thrusters provided the best position-keeping performance. The vessel's DP control performance was also analyzed in relation to the increased environmental load caused by the presence of a wind turbine, using a capability plot. The vessel's performance was evaluated in three different states: floating with no load, during the loading of a wind turbine and suction buckets, and after the wind turbine has been installed. The use of 750 kW and 1,000 kW thrusters was also considered, and the environmental loads in the Saemangeum coastal area and the environmental load when a 5-Megawatt wind turbine is on board were assessed. The study concluded that at least four thrusters should be used for DP to safely manage the installation process of wind turbines.

A New Structure of Communication System for Monitoring and Control of Heterogeneous Wind Tubines (이종 풍력 터빈의 감시 제어를 위한 통신 시스템 구조)

  • Kim, Tae-Hyoung;Hwang, Tae-Ho;Ham, Kyung-Sun
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.40-45
    • /
    • 2011
  • As increasing the importance of renewable energy recently, the scale of a wind power plant is increasing to the number of GW scale and specially, it is trend to move from onshore to offshore to use the higher quantity and quality of wind. Consequently to meet the trend, it is largely considered the importance of communication protocol to control and monitor remotely. But, because the communication protocol between the control center and a wind turbine has been independently developed by each wind turbine vendor, it is absence of the compatibility and extensibility when the heterogeneous wind turbines are installed in the wind farm. The IEC 61400-25 is the specifying standard for these problems in Europe. In this paper, we will show the state of these problems and present a new structure of communication based on the IEC 61400-25 to get the compatibility and extensibility between a control center and wind turbines.

  • PDF

Development of the Furling Control Type Small Wind Turbine System (과풍속 출력 제한형 소형 풍력 발전장치 개발)

  • Choi, Young-Chul;Kim, Chul-Ho;Lee, Hyun-Chae;Seo, Young-Taek;Han, Young-Oun;Song, Jung-Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.6
    • /
    • pp.693-701
    • /
    • 2012
  • In this study, a small wind turbine airfoil specialized for national wind condition was designed in order to develop the furling control type HAWT. And then a flow analysis was carried out based on the blade drawing which was designed to characterize of the developed airfoil. The result of the flow analysis showed that the torque on the 3 blades was 180.23N.m. This is equivalent to an output power of 5.66kw and an output efficiency of 0.44. Then we produced and constructed a 3kW - furling control type HAWT by getting the system unit design technology such as the specialized furling control device. By operating this turbine, we could get 3kW of the rated power at a wind speed of 10.5m/s through the ability test. Cut-in wind speed was 2m/s, generator efficiency was 92% at the rated power output. Sound power level was 87.2dB(A). Also we observed that the output power was limited to 10.5m/s with furling system operation.

Simplified Wind Turbine Modeling and Calculation of PCC Voltage Variation according to Grid Connection Conditions (간략화된 풍력발전기 모델링과 계통연계 조건에 따른 PCC 전압 변동량 계산)

  • Im, Jl-Hoon;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2402-2409
    • /
    • 2009
  • This paper proposed a simple and helpful analysis model of voltage variation in order to predict the voltage variation at PCC (Point of Common Coupling), when a wind turbine is connected in an isolated grid. The PCC voltage flucuates when the wind turbine outputs active power to an isolated grid. This voltage variation is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And It is different according as where wind turbine is connected. To solve the problem of voltage variation, this paper proposed the reactive power control. To verify the proposed analysis model, this paper utilized PSCAD/EMTDC Simulation and the field measurement data of the voltage variation during the wind power generation.

Design of Power and Load Reduction Controller for a Medium-Capacity Wind Turbine (중형 풍력터빈의 출력 및 타워 하중저감 제어기 설계)

  • Kim, Kwansu;Paek, Insu;Kim, Cheol-Jin;Kim, Hyun-Gyu;Kim, Hyoung-Gil
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.1-12
    • /
    • 2016
  • A control algorithm for a 100 kW wind turbine is designed in this study. The wind turbine is operating as a variable speed variable pitch (VSVP) status. Also, this wind turbine is a permanent magnet synchronous generator (PMSG) Type. For the medium capacity wind turbine considered in this study, it was found that the optimum tip speed ratios to achieve the maximum power coefficients varied with wind speeds. Therefore a commercial blade element momentum theory and multi-body dynamics based program was implemented to consider the variation of aerodynamic coefficients with respect to Reynolds numbers and to find out the power and thrust coefficients with respect tip speed ratio and blade pitch angles. In the end a basic power controller was designed for below rated, transition and above rated regions, and a load reduction algorithm was designed to reduce tower vibration by the nacelle motion. As a result, damage equivalent Load (DEL) of tower fore-aft has been reduced by 32%. From dynamic simulations in the commercial program, the controller was found to work properly as designed. Experimental validation of the control algorithm will be done in the future.

750kW-class DFIG Wind Turbine Monitoring System Development and Study on Scheme for Applying Standardized Communication (750kW급 DFIG 풍력 발전기 모니터링 시스템 개발 및 통신 표준화 적용 방안에 관한 연구)

  • Lee, Duck-Su;Lee, Jun-Chul;Choi, In-Sun;Choi, Young-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.327-330
    • /
    • 2008
  • This paper presents monitoring system for 750kW-class DFIG wind turbine generator system and an architecture for applying standardized communication, IEC61400-25. Monitoring and control system is consists of wind turbine PLC, Local and Remote I/O Server, HMI. and Web-server. Proposed System has been demonstrated in Daegi-ri, Kangwon-do, which aims to test local and/or remote monitoring and control system and evaluate the performance of 750kW-class WTS. Finally we described the design of logical nodes and services based on IEC61400-25 and its application scheme.

  • PDF

Assessment of Wind Turbine Load and Performance Effects by Yaw Control (풍력 터빈의 요 제어에 따른 하중 및 성능 영향성 평가)

  • Kim, Jin;Kim, Ji Yon;Koh, Jang Wook;Kweon, Ki Yeong
    • Journal of Wind Energy
    • /
    • v.4 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • The wind generally includes turbulence characteristics in nature. So the yaw errors between wind turbine direction and wind direction occur due to turbulence fluctuation. The yaw errors affect the fatigue load of wind turbine system and power reduction. The components of turbulence intensity are different from those of each site where the wind turbines are installed. We studied that the fatigue load and power efficiency are improved by controlling yaw motions. In this study, we controlled the averaged yaw error time according to site conditions by turbulence intensity.

Fabrication and Electrical Properties of Blades for Wind Turbine System (풍력발전기용 블레이드의 제작 및 전기적 특성)

  • Lee, Jong-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.345-346
    • /
    • 2006
  • This study proposes a development of blades for the 6W class small wind turbine system, which is applicable to relatively low speed region like Korea, and very easy to pitch control. The materials of the blades was used for the still. Electrical properties of blades improved by increasing with wind speed. The maximum output showed at $10^{\circ}$ of pitch angle and about 3.8[W] at 5.5[m/s] of wind speed.

  • PDF

Experimental Study on Frequency Support of Variable Speed Wind Turbine Based on Electromagnetic Coupler

  • You, Rui;Chai, Jianyun;Sun, Xudong;Bi, Daqiang;Wu, Xinzhen
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.195-203
    • /
    • 2018
  • In the variable speed Wind Turbine based on ElectroMagnetic Coupler (WT-EMC), a synchronous generator is coupled directly to the grid. Therefore, like conventional power plants, WT-EMC is able to inherently support grid frequency. However, due to the reduced inertia of the synchronous generator, WT-EMC is expected to be controlled to increase its output power in response to a grid frequency drop to support grid frequency. Similar to the grid frequency support control of Type 3 or Type 4 wind turbine, inertial control and droop control can be used to calculate the WT-EMC additional output power reference according to the synchronous generator speed. In this paper, an experimental platform is built to study the grid frequency support from WT-EMC with inertial control and droop control. Two synchronous generators, driven by two induction motors controlled by two converters, are used to emulate the synchronous generators in conventional power plants and in WT-EMCs respectively. The effectiveness of the grid frequency support from WT-EMC with inertial control and droop control responding to a grid frequency drop is validated by experimental results. The selection of the grid frequency support controller and its gain for WT-EMC is analyzed briefly.