• Title/Summary/Keyword: wind power inverter

Search Result 131, Processing Time 0.025 seconds

Virtual D-STATCOM Considering Distance (거리를 고려한 Virtual D-STATCOM)

  • Kim, Tae-Hun;Oh, Jeong-Sik;Park, Jang-Hyon;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.151-158
    • /
    • 2019
  • In this paper, we construct a Virtual D-STATCOM using a number of grid-connected inverters installed in solar and wind power plants and compensate the reactive power of the cable depending on the reactive power of the load of the power distribution system and the distance to the power distribution line We propose a method to compensate the reactive power of the PCC stage near the substation without installing the existing single large capacity D-STATCOM. The proposed method is verified by Matlab Simulink simulation and its operation principle and reactive power compensation.

A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions (PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구)

  • Kim, Kyeong-Hwa;Song, Hwa-Chang;Choi, Byoung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.

Power Balancing Strategy in the Microgrid During Transient (마이크로그리드 과도상태 시 전력 수급 균형 전략)

  • Seo, Jae-Jin;Lee, Hak-Ju;Jung, Won-Wook;Won, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

Normal Operation Characteristics of 30kW Scale CVCF Inverter-Based Micro-grid System (30kW급 CVCF 인버터 기반의 Micro-grid의 정상상태 운용특성에 관한 연구)

  • Ferreira, Marito;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.662-671
    • /
    • 2020
  • Recently, for the purposes of reducing carbon dioxide(CO2) emissions in the island area, countermeasures to decrease the operation rate of diesel generator(DG) and to increase one of renewable energy sources(RES) is being studied. In particular, the demonstration and installation of stand-alone micro-grid(MG) system which is composed of DG, RES and energy storage system(ESS) has been implemented in some island areas such as Gapa-do, Gasa-do and Ulleung-do island. However, many power quality(PQ) problems may be occurred due to an intermittent output of RES including photovoltaic(PV) system and wind power(WP) system in a normal operating of constant voltage & constant frequency(CVCF) inverter-based MG system. Therefore, this paper presents a modeling of the 30kW scale MG system using PSCAD/EMTDC, and also implements a 30kW scale CVCF inverter-based MG system as test devices to analyze normal operating characteristics of MG system. From the simulation and test results, it is confirmed that the proposed methods are useful and practical tools to improve PQ problems such as under-voltage, over-voltage and unbalanced load in CVCF inverter-based MG system.

CVCF Control of Stand-Alone Wind Power System (독립형 풍력발전 시스템의 CVCF 제어)

  • Kim H.K.;Abo-Khalil Ahmed;Lee D.C.;Seok J.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.379-382
    • /
    • 2003
  • In this paper, a novel nonlinear control method of the CVCF(constant voltage and constant frequency output voltage for the three-phase PWM inverter is proposed, which gives high dynamic responses at load variation as well as zero steady-state error. The experimental results are shown th verify the validity of the proposed scheme.

  • PDF

A Novel Anti-islanding Method of a Grid-connected Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전 시스템 계통연계 인버터의 새로운 단독운전방지 기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.427-428
    • /
    • 2013
  • 풍력발전과 같은 분산전원이 계통에 연계되어 운전될 경우, 계통연계 규정에 따라 운전해야 한다. 특히 계통사고에 의해 계통과 분리되었음에도 불구하고, 지속적으로 운전하는 것을 단독운전 이라 한다. 이러한 단독운전은 전기설비의 손상을 일으킬 수 있으므로 계통연계 규정에 따라 이를 빠르고 정확하게 검출하여야 한다. 본 논문에서는 이러한 단독운전을 검출하기 위해서 NDZ(Non-Detecton Zone)를 갖지 않는 고조파 주입 기법의 새로운 고조파 계산 및 검출 알고리즘 제안한다.

  • PDF

Characteristics of Bidirectional DFIG for Wind Power Generating System (양방향제어를 이용한 풍력발전용 DFIG의 특성)

  • Park, Young-Do;Lee, Woo-Suk;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.969-971
    • /
    • 2000
  • This paper deals with characteristics analysis of Doubly-Fed Induction Generator (DFIG) in the supersynchronous speed regions. by control of voltage fed to the rotor using for bidirection control. This rotor voltage is controlled by con troll of inverter switching frequency and fire angle. Characteristics of DFIG is analyzed by steady-state algebraic equations of the equivalent circuit using numerical analysis. And it is compared with results of experiment. Consequently, this paper presented to find the optimal magnitude of voltage fed to the rotor for maximum power and PF, using result of characteristics analysis.

  • PDF

Cascaded Boost Multilevel Converter for Distributed Generation Systems

  • Kim, Ki-Mok;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.70-71
    • /
    • 2017
  • This paper presents a new cascaded boost multilevel converter topology for distributed generation (DG) systems. Most of DG systems, such as photovoltaic (PV), wind turbine and fuel cells, normally require the complex structure power converters, which makes the system expensive, complex and hard to control. However, the proposed converter topology can generate a much higher output voltage just by using the standard low-voltage switch devices and low voltage DC-sources in a simplified structure, also enhancing the reliability of the switch devices. Simulation and experimental results with a 1.2kW system are presented to validate the proposed topology and control method.

  • PDF

The efficient DC-link voltage design of the Type 4 wind turbine that satisfies HVRT function requirements (HVRT 기능 요구조건을 만족하는 Type 4 풍력 발전기의 효율적인 직류단 전압 설계)

  • Baek, Seung-Hyuk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.399-407
    • /
    • 2021
  • This paper proposes the DC-link voltage design method of Type 4 wind turbine that minimizes power loss and satisfies the High Voltage Ride Through(HVRT) function requirements of the transmission system operator. The Type 4 wind turbine used for large-capacity offshore wind turbine consists of the Back-to-Back converter in which the converter linked to the power grid and the inverter linked to the wind turbine share the DC-link. When the grid high voltage fault occurs in the Type 4 wind turbine, if the DC-link voltage is insufficient compared to the fault voltage level, the current controller of the grid-side converter can't operate smoothly due to over modulation. Therefore, to satisfy the HVRT function, the DC-link voltage should be designed based on the voltage level of high voltage fault. However, steady-state switching losses increase further as the DC-link voltage increases. Therefore, the considerations should be included for the loss to be increased when the DC-link voltage is designed significantly. In this paper, the design method for the DC-link voltage considered the fault voltage level and the loss is explained, and the validity of the proposed design method is verified through the HVRT function simulation based on the PSCAD model of the 2MVA Type 4 wind turbine.

Implementation of Super High-speed Permanent Magnet Synchronous Machine Drive (영구 자석 동기 전동기의 초고속 운전에 관한 연구)

  • Kim, Myoung-Ho;Yim, Jung-Sik;Sul, Seung-Ki;Lim, Sung-Il
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.329-335
    • /
    • 2008
  • Recently, super high-speed motor drives have been available due to the development of power electronics technology And they are used in various fields of industry because of their advantages. This paper describes the control algorithm for a permanent magnet synchronous motor(PMSM) drive at the speed of 118,000r/min using DSP and IGBT inverter. Hall sensors are implemented to measure the rotor position and speed, and a speed observer is used to reduce the performance deterioration caused by the low resolution of hall sensors. To enhance the output power capacity in the high-speed operating region, a flux weakening controller which also can work as an anti-wind up controller is used. Computer simulations and experiments are peformed to validate the proposed method.