• Title/Summary/Keyword: wind cable

Search Result 300, Processing Time 0.029 seconds

MR fluid damper-based smart damping systems for long steel stay cable under wind load

  • Jung, Hyung-Jo;Jang, Ji-Eun;Choi, Kang-Min;Lee, Heon-Jae
    • Smart Structures and Systems
    • /
    • v.4 no.5
    • /
    • pp.697-710
    • /
    • 2008
  • Long steel stay cables, which are mainly used in cable-stayed bridges, are easy to vibrate because of their low inherent damping characteristics. A lot of methods for vibration reduction of stay cables have been developed, and several techniques of them have been implemented to real structures, though each has its limitations. Recently, it was reported that smart (i.e. semi-active) dampers can potentially achieve performance levels nearly the same as comparable active devices with few of the detractions. Some numerical and experimental studies on the application of smart damping systems employing an MR fluid damper, which is one of the most promising smart dampers, to a stay cable were carried out; however, most of the previous studies considered only one specific control algorithm in which they are interested. In this study, the performance verification of MR fluid damper-based smart damping systems for mitigating vibration of stay cables by considering the four commonly used semi-active control algorithms, such as the control algorithm based on Lyapunov stability theory, the maximum energy dissipation algorithm, the modulated homogeneous friction algorithm and the clipped-optimal control algorithm, is systematically carried out to find the most appropriate control strategy for the cable-damper system.

Wave Simulation for Submarine Cable Route of Southwest Sea Offshore Wind Farm Using the SWAN Model (SWAN 모델을 이용한 서남해 해상풍력단지 해저케이블 경과지의 파랑 수치모의)

  • Ryu, Hwang-Jin;Kim, Sang-Ho;Kwoun, Chul-Hui;Cho, Kwang-Woo;Maeng, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.5
    • /
    • pp.583-590
    • /
    • 2015
  • Submarine cable installation is essentials for grid connection between existing power grid and newly produced electricity which will be from offshore wind farm in Southwest sea area of Korea. Especially, submarine cable route and protection method is designed in order to ensure the economical efficiency, workability and stability of submarine cable installation. On this paper, we will give the basic information about the submarine cable route and protection method of offshore wind farm which will be built in Southwest sea area of Korea. For this, we have a numerical simulation at high and low tide based on the third-generation wave model SWAN(Simulating WAves Nearshore) using the long term wave data from Korea Institute of Ocean Science and Technology(KIOST). The results of the study, year mean Hs is 1.03m, Tz is 4.47s and dominant wave direction is NW and SSW When the incident wave direction is NW(Hs: 7.0 m, Tp: 11.76s), the distribution of shallow water design wave height Hs was calculated about 4.0~5.0m at high tide and 2.0~3.0m at low tide. When the incident wave direction is SSW(Hs: 5.84 m, Tp: 11.15s), the distribution of shallow water design wave height Hs was calculated about 3.5~4.5m at high tide and 1.5~2.5m at low tide. The wave direction on a dominant influence in the section of longitude UTM 249749~251349(about 1.6 km) and UTM 251549~267749(about 16.2 km) in the submarine cable route are each NW and SSW. Prominently, wave focusing phenomenon appears between Wi-do and Hawangdeung-do, in this sea area is showing a relatively high wave hight than the surrounding sea areas.

A Study on the Power Loss Cost of Inner-Grid in the Offshore Wind Farm (해상풍력단지 내부그리드의 전력손실비용에 관한 연구)

  • Shin, Je-Seok;Kim, Sung-Yul;Bae, In-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.72-77
    • /
    • 2014
  • The cross-section area of cable in the Offshore Wind Farm (OWF) is smaller than that in the onshore wind farm. Because the power loss in OWF is large relatively, the power loss is a key element for the economic evaluation of OWF design. The availability of wind turbine in OWF and the size of OWF are larger than those of onshore wind farm. If the economic evaluation of OWF ignores the availability of wind turbines, the power loss cost of OWF is overpriced. Since there are so many wind turbines, also, the calculation of power loss should be more accurate. In this paper, a method to calculate power loss is proposed for the design of big and complex inner-grid in OWF. The 99.5MW OWF is used for case study to see what effect the proposed method have on the power loss cost.

Vibration Characteristics of the Tower Structures of Wind Turbine Generators (풍력발전기 타워 구조의 진동 특성)

  • Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.49-59
    • /
    • 2009
  • Vibrations of the tower structures of 750kW and 6kW wind turbines(WT) are investigated by measurement and analysis. Acceleration responses of the WT towers under various operation condition are monitored in real time by the remote monitoring system using LabVIEW. Using the monitoring system, resonance condition of the tower structures is diagnosed with the wind speed data within the operating speed range. To predict the tower resonance frequency, 750 kW tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. For 6 kW WT, Rayleigh-Ritz analysis is carried out on the tower-cable coupled system. Calculated tower bending frequency is in good agreement with the measured value. Using the analysis model, parametric study is available in order to prevent the severe resonance.

  • PDF

Dynamic response of a bridge deck with one torsional degree of freedom under turbulent wind

  • Foti, Dora;Monaco, Pietro
    • Wind and Structures
    • /
    • v.3 no.2
    • /
    • pp.117-132
    • /
    • 2000
  • Under special conditions of turbulent wind, suspension and cable-stayed bridges could reach instability conditions. In various instances the bridge deck, as like a bluff body, could exhibit single-degree torsional instability. In the present study the turbulent component of flow has been considered as a solution of a differential stochastic linear equation. The input process is represented by a Gaussian zero-mean white noise. In this paper the analytical solution of the dynamic response of the bridge has been determined. The solution has been obtained with a technique of closing on the order of the moments.

Fatigue of tubular steel lighting columns under wind load

  • Peil, U.;Behrens, M.
    • Wind and Structures
    • /
    • v.5 no.5
    • /
    • pp.463-478
    • /
    • 2002
  • Lighting and traffic signal columns are mainly stressed by excitation due to natural, gusty wind. Such columns typically have a door opening about 60 cm above ground level for the connection of the buried cable with the column's electric system. When the columns around this notch are inadequately designed, vibrations due to gusty winds will produce considerable stress amplitudes in this area, which lead to fatigue cracks. To give a realistic basis for a reliable and economic design of lighting and traffic signal columns, a number of experimental and theoretical investigations have been made. The proposed design concept allows the life of such columns to be assessed with a satisfactory degree of accuracy.

Experiments on the Submarine Cable Protection Methods Considering the Connection Type (체결형상을 고려한 해저케이블 보호공법에 관한 실험)

  • Yoon, Jae Seon;Ha, Taemin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.329-329
    • /
    • 2017
  • In this study attempted to evaluate the stability of the protection methods by examining hydraulic characteristics of the area around the point in which marine cable protector is installed such as surf zone occurrence point of shore-end submarine cables suitable for coastal marine environmental conditions, flow rate t the tope of the protector and maximum wave height, and to provide basic data for the selection of the optimal protection method. In performing hydraulic model experiments, the topography of submarine cable installation location was reproduced in 2-D sectional channel, and models appropriate for experimental scale and similitude law were produced and installed for each condition of submarine cables and protectors. Since the topography and submarine cable protectors were reproduced and installed in 2-D sectional channel, the exact reproduction of surf and transformation in shallow water zone was possible, and thus the physical properties could be clearly analyzed. For stability review, an experiment to examine the stability was conducted using a wave maker with 50-year frequency design waves as target, and wave height and cycles were applied based on the approximate lowest low water level(Approx. L.L.W), which is the most dangerous in submarine cable protection methods. As for experimental time, typhoon passing time in summer (about 3 hours) was applied, and wave patterns and deviation ratio of the submarine cable protector were investigated after making irregular waves corresponding to design waves. In addition, current meter and wave height meter were installed at the installation location of the submarine cable protector, and the flow rates and wave height at the top of the protector were measured and analyzed to review hydraulic properties.

  • PDF

An analysis of structural characteristic's changing as stranded wire's pitch changing of wind turbine type cable's conductor by CAE techniques (CAE 기법을 활용한 풍력 케이블의 도체 연선 피치 변화에 따른 구조적 특성 변화 분석)

  • Park, Moon-Gun;Jang, Jin-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.276_277
    • /
    • 2009
  • 풍력 케이블의 nacelle부와 Tower 사이에 포설되는 케이블은 사용 환경의 특성상 장력+비틀림의 스트레스를 받는다. 이러한 사용 환경 때문에 케이블은 전기적인 특성 뿐 아니라 반복 운동을 하는 환경에 대해 구조적인 특성에 대해서도 검토가 요구되어진다. 본 논문에서는 풍력 케이블의 핵심 검토 요소로 도체의 구조적 위험 요소를 줄이기 위한 연구 대상으로 도체의 (*)피치 변화의 특성을 분석하였으며, 피치가 길어지면 도체에 발생되어지는 응력(스트레스)이 작아질 것이고 피치가 짧아지면 도체에 발생되어지는 응력(스트레스)이 커질 것이라는 일반적인 상식을 벗어나 각 피치별 응력(스트레스)의 최저점들을 찾게 되었고 그 중 유연성을 함께 고려하여 품질의 향상을 기여하는 최적 피치를 선정하였다.

  • PDF

Smart Control Techniques for Vibration Suppression of Stay Cable (사장 케이블 제진을 위한 스마트 제진 기법)

  • Jung Hyung-Jo;Park Chul-Min;Cho Sang-Won;Lee In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.264-271
    • /
    • 2006
  • Stay cables, such as used in cable-stayed bridges, are prone to vibration due to their low inherent damping characteristics. It has been reported that a semiactive control system using MR dampers could potentially achieve both the better performance compared to a passive control system and the adaptability with few of the detractions. However, a control system including a power supply, a controller and sensors is required to improve the control performance of MR dampers. This complicated control system is not effective to most of large civil structures such as long-span bridges and high-rise buildings. This paper proposes a smart damping system which consists of an MR damper and the electromagnetic induction (EMI) part that is considered as an external power source to the MR damper. The control performance of the proposed damping system has been compared with that of the passive-type control systems employing an MR damper and a linear viscous damper.

  • PDF

Design Specifications of Cable Stayed Bridge Across Chambal River (참발강 횡단 사장교의 설계기준)

  • Kim, Mo-Seh;Yoo, Jun-Yeol;Cho, Eu-Kyeong;Lee, Sang-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.41-46
    • /
    • 2008
  • The bridge across Chambal River consists of two approach bridges and a cable stayed bridge with concrete girder and pylon. And the main bridge has been designed mainly based on AASHTO LRFD. This article covers design specifications from AASHTO LRFD, which are applied to load combinations and structural verification. And it also covers local standards applied in definition of loads such as live load, wind load, temperature, etc. In addition, the difference between applied design specifications and Korean standards is mentioned in this article briefly.