• Title/Summary/Keyword: width of device

Search Result 718, Processing Time 0.029 seconds

Design and Fabrication of C-Band GaN Based on Solid State High Power Amplifier Unit for a Radar System (레이다용 C-대역 GaN 기반 고출력전력증폭장치 설계 및 제작)

  • Jung, Hyoung Jin;Park, Ji Woong;Jin, Hyoung Seok;Lim, Jae Hwan;Park, Se Jun;Kang, Min Woo;Kang, Hyun Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.685-697
    • /
    • 2017
  • In this paper, it is presented the result of design and fabrication for C-band solid state high power amplifier unit and components using in search radar. The solid state power amplifier(SSPA) assembly was fabricated using GaN(Gallium Nitride), which is semiconductor device, and the transmit signal output power of the solid state high power amplifier unit is generated by combining the transmit signal power of the solid state power amplifier configured in parallel through a design and fabricated waveguide type transmit signal combine assembler. Designed solid state high power amplifier unit demonstrated C-band 500 MHz bandwidth, maximum 10.5% duty cycle, transmit pulse width from $0.0{\mu}s{\sim}000{\mu}s$, and transmit signal power is 44.98 kW(76.53 dBm).

A Study on DC Traction Power Supply System Using PWM Converter (PWM컨버터를 적용한 경전철 전력공급시스템에 관한 연구)

  • Kim, Joorak;Park, Chang-Reung;Park, Kijun;Kim, Joo-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.250-254
    • /
    • 2016
  • Currently, power conversion system which converts AC to DC Power is applied in domestic urban railway. The diode rectifier is used in most of them. However the diode rectifier can not control the output voltage and can not regenerate power as well. On the other hand, PWM (pulse width modulation) converter using IGBT (isolated gate bipolar transistor) can control output voltage, allowing it to reduce the output voltage drop. Moreover the Bi-directional conduction regenerates power which does not require additional device for power regeneration control. This paper compared the simulation results for the DC power supply system on both the diode rectifier and the PWM converter. Under the same load condition, simulation circuit for each power supply system was constructed with the PSIM (performance simulation and modeling tool) software. The load condition was set according to the resistance value of the currently operating impedance of light rail line, and the line impedance was set according to the distance of each substations. The train was set using a passive resistor. PI (proportional integral) controller was applied to regulate the output voltage. PSIM simulation was conducted to verify that the PWM Converter was more efficient than the diode rectifier in DC Traction power supply system.

Synchronous Buck Converter with High Efficiency and Low Ripple Voltage for Mobile Applications (고 효율 저 리플 전압 특성을 갖는 모바일용 동기 형 벅 컨버터)

  • Yim, Chang-Jong;Kim, Jun-Sik;Park, Shi-Hong
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.319-323
    • /
    • 2011
  • In this paper presents a new model of dual-mode synchronous buck converter with dynamic control for mobile applications was proposed. The proposed circuit can operate at 2.5MHz with supply voltage 2.5V to 5V for low ripple and minimum inductor and capacitor size, which is suitable for single-cell lithium-ion battery supply mobile applications. For high efficiency, the proposed circuit adopts synchronous type and dynamic control. The proposed circuit is designed by using the device parameter of TSMC 0.18um BCD process and the performance is evaluated by Cadence spectre. Experimental board level results show the maximum conversion efficiency is 96% at 100mA load current.

Analysis of Threshold Voltage Characteristics for FinFET Using Three Dimension Poisson's Equation (3차원 포아송방정식을 이용한 FinFET의 문턱전압특성분석)

  • Jung, Hak-Kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2373-2377
    • /
    • 2009
  • In this paper, the threshold voltage characteristics have been analyzed using three dimensional Poisson's equation for FinFET. The FinFET is extensively been studing since it can reduce the short channel effects as the nano device. We have presented the short channel effects such as subthreshold swing and threshold voltage for PinFET, using the analytical three dimensional Poisson's equation. We have analyzed for channel length, thickness and width to consider the structural characteristics for FinFET. Using this model, the subthreshold swing and threshold voltage have been analyzed for FinFET since the potential and transport model of this analytical three dimensional Poisson's equation is verified as comparing with those of the numerical three dimensional Poisson's equation.

Optimal Design of Long-fiber Composite Cover Plate with Ribs (리브를 가진 장섬유 복합재료 커버 플레이트의 최적설계)

  • Han, Min-Gu;Bae, Ji-Hun;Lee, Sung-Woo;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Carbon fiber reinforced composites have light weight and high mechanical properties. These materials are only applicable in limited shape structure cause by complex curing process and low drapability. To solve this problem, Long Fiber Prepreg Sheet (LFPS) has been proposed. In this research, electric device cover plate was selected and designed by using LFPS. Before the design process, we analyzed the target structure to which the rib structures were applied. And 8-inch tablet PC product was selected. For FE analysis, simple loading and boundary conditions were applied. Stiffness of rib structure was investigated according to the rib pattern and shape changes. Rib pattern and shape were selected based on fixed volume condition analysis results. And uneven rib width model was selected for the best case whose deflection was reduced 6~10% than uniform rib model.

Design and Implementation of High-Resolution Image Transmission Interface for Mobile Device (모바일 환경을 위한 맞춤형 서비스 유비쿼터스 영상전송 시스템의 설계)

  • Lee, Sang-Wook;Ahn, Yong-Beom;Kim, Eung-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.791-799
    • /
    • 2008
  • An image recognition for surrounding conditions is very important in image transmission. In recently rears, as the information infrastructure is more general, the user-centered demands in which they want to identify by object's states image using wire or wireless environment have increased. However, existing mobile solution could be hard to expect high quality mage, because limitation of software processing according as network based on mobile terminal which has low band width supports software codec. To solve this weak point, this paper describes on hardware codec design based on MPEG-4 which is international video compression standard. Implemented system contains the embedded CPU for optimized design and it works high quality service as transmission speed and resolution in mobile circumstance.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

The Thickness Measurement of Masticatory Mucosa on the Hard Palate and Maxillary Tuberosity in Healthy Korean Adults (건강한 한국 성인에서 경구개와 상악결절 부위 저작점막의 두께 측정)

  • Cho, Ik-Hyun;Park, Jung-Mi;Chang, Moon-Taek;Kim, Hyung-Seop;Kim, Hyun-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.641-649
    • /
    • 2001
  • The aim of present study was to assess the thickness of masticatory mucosa on the hard palate and tuberosity as a potential donor site for mucogingival surgery. Thickness measurement was performed in 30 dental college students who are periodontally healthy, with a recently developed, ultrasonic device(SDM). The mean age of study subjects was 23.7(range 21-29) years old and the subjects were composed of 18 males and 12 females. Eighteen standard measurement points were defined on the hard palate, located on 3 lines which ran at different distances parallel to the gingival margin. Six positions were designated on each of these 3 lines between the level of the canine and the second molar. On the tuberosity, 6 standard measurement points were defined, located on 2 lines running parallel to the gingival margin at different distances. Data were analyzed to determine differences in gender, between different positions, and between lines, by an analysis of variance. The results showed that the mucosa of the tuberosity was significantly thicker than that of the hard palate region. Gender did not influence the thickness of masticatory mucosa, either on the hard palate or the tuberosity. On the hard palate, mucosa thickness increased as the distance from the marginal gingiva increased. The mucosa over the palatal root of the maxillary first molar was significantly thinner than that at all other positions on the hard palate. Measurement error at palate was 0.25mm, at tuberosity 0.51mm. No difference in the thickness of masticatory mucosa on palate and tuberosity was found between men and women. On the hard palate, soft tissue thickness progressively increased in sites further from the gingival margin. Therefore, we may harvest more thicker graft on the tuberosity that has more masticatory mucosa thickness than hard palate, however the width may not be sufficient for using.

  • PDF

Opto-Electrochemical Sensing Device Based on Long-Period Grating Coated with Boron-Doped Diamond Thin Film

  • Bogdanowicz, Robert;Sobaszek, Michał;Ficek, Mateusz;Gnyba, Marcin;Ryl, Jacek;Siuzdak, Katarzyna;Bock, Wojtek J.;Smietana, Mateusz
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.705-710
    • /
    • 2015
  • The fabrication process of thin boron-doped nanocrystalline diamond (B-NCD) microelectrodes on fused silica single mode optical fiber cladding has been investigated. The B-NCD films were deposited on the fibers using Microwave Plasma Assisted Chemical Vapor Deposition (MW PA CVD) at glass substrate temperature of 475 ℃. We have obtained homogenous, continuous and polycrystalline surface morphology with high sp3 content in B-NCD films and mean grain size in the range of 100-250 nm. The films deposited on the glass reference samples exhibit high refractive index (n=2.05 at λ=550 nm) and low extinction coefficient. Furthermore, cyclic voltammograms (CV) were recorded to determine the electrochemical window and reaction reversibility at the B-NCD fiber-based electrode. CV measurements in aqueous media consisting of 5 mM K3[Fe(CN)6] in 0.5 M Na2SO4 demonstrated a width of the electrochemical window up to 1.03 V and relatively fast kinetics expressed by a redox peak splitting below 500 mV. Moreover, thanks to high-n B-NCD overlay, the coated fibers can be also used for enhancing the sensitivity of long-period gratings (LPGs) induced in the fiber. The LPG is capable of measuring variations in refractive index of the surrounding liquid by tracing the shift in resonance appearing in the transmitted spectrum. Possible combined CV and LPG-based measurements are discussed in this work.