• Title/Summary/Keyword: white light imaging

Search Result 48, Processing Time 0.025 seconds

A Case of Necrotizing Meningoencephalitis in a Maltese Dog (말티즈견에서 괴사성 뇌막뇌염 증례)

  • Park Jin-hee;Eom Ki-dong;Kim Jae-hoon;Seong Yun-sang;Lee Hae-oon;Lee Sang-gwan;Jang Kwang-ho;Lee Keun-woo;Kweon Oh-deog;Park Hyun-jung;Oh Tae-ho
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.284-287
    • /
    • 2005
  • A 18-month-old, male Maltese dog with acute seizure was referred to Veterinary Medical Teaching Hospital, Kyungpook National University. Abnormal neurologic findings included a tendency to fall to the left, turn and circle to the right, negative bilateral menace responses and pupillary light reflexes, and diminished responses to facial sensation testing on both sides. Radiographic signs were normal, except for occipital dysplasia. Magnetic resonance imaging of the brain revealed bilateral asymmetric ventriculomegaly, which is more on left side. Cerebral edema was also suspected. The dog died after 9 days from the onset of seizure, and a necropsy was performed. Histopathologically, the brain lesions in the meninges and the cerebral cortex of this dog was presented. There was severe diffuse nonsuppurative inflammation in perivascular area of the meninges and the cerebral white matter. Based on the results, this case was diagnosed as necrotizing meningoencephalitis in Maltese dog.

A Correlation Study of the Body Mass Index and the Indicators of Oral Health (체질량지수와 구강건강지표 사이의 상관성에 대한 연구)

  • Shim, Hyeyoon;Park, Jeong Hwan;Lee, Sanghun;Kim, Hojun
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.21 no.1
    • /
    • pp.32-41
    • /
    • 2021
  • Objectives: We aim to observe the relation of body mass index (BMI) and the indicators of oral health. Methods: 400 subjects participated in the study. The BMI values are calculated from the height and weight. For the tongue diagnosis, we used the tongue imaging device to analyze the color, tongue coating, and tooth marks. We measured the concentration of hydrogen sulfide (H2S) and methyl mercaptan (CH3SH) to evaluate the halitosis. The dry mouth was evaluated through the measurement of saliva secretion and with the questionnaire asking the frequency of dry mouth. Results: The BMI values were significantly higher in the group with light-white and blue-purple colored tongue, and significantly lower for lightly-coated tongue. However, the correlation of BMI and the amounts of saliva secretion was not significant as well as in the correlation of BMI and the concentration of H2S, CH3SH. In tongue diagnosis, the subjects who had blue-purple colored tongue also had significantly higher H2S and CH3SH, but tendency of lower saliva secretion. Conclusion: We obtain data showing that BMI value and the indicators of oral health including tongue diagnosis have meaningful correlation.

Cortical Network Activated by Korean Traditional Opera (Pansori): A Functional MR Study

  • Kim, Yun-Hee;Kim, Hyun-Gi;Kim, Seong-Yong;Kim, Hyoung-Ihl;Todd. B. Parrish;Hong, In-Ki;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.113-119
    • /
    • 2000
  • The Pansori is a Korean traditional vocal music that has a unique story and melody which converts deep emotion into art. It has both verbal and emotional components. which can be coordinated by large-scale neural network. The purpose of this study is to illustrate the cortical network activated by a Korean traditional opera, Pansori, with different emotional valence using functional MRI (fMRI).Nine right-handed volunteers participated. Their mean age was 25.3 and the mean modified Edinburgh score was +90.1. Activation tasks were designed for the subjects to passively listen to the two parts of Pansories with sad or hilarious emotional valence. White noise was introduced during the control periods. Imaging was conducted on a 1.5T Siemens Vision Vision scanner. Single-shot echoplanar fMRI scans (TR/TE 3840/40 ms, flip angle 90, FOV 220, 64 x 64 matrix, 6mm thickness) were acquired in 20 contiguous slices. Imaging data were motion-corrected, coregistered, normalized, and smoothed using SPM-96 software.Bilateral posterior temporal regions were activated in both of Pansori tasks, but different asymmetry between the tasks was found. The Pansori with sad emotion showed more activation in the light superior temporal regions as well as the right inferior frontal and the orbitofrontal areas than in the right superior temporal regions as well as the right inferior frontal and the orbitofrontal areas than in the left side. In the Pansori with hilarious emotion, there was a remarkable activation in the left hemisphere especially at the posterior temporal and the temporooccipital regions as well as in the left inferior and the prefrontal areas. After subtraction between two tasks, the sad Pansori showed more activation in the right temporoparietal and the orbitofrontal areas, in contrast, the one with hilarious emotion showed more activation in the left temporal and the prefrontal areas. These results suggested that different hemispheric asymmetry and cortical areas are subserved for the processing of different emotional valences carried by the Pansories.

  • PDF

Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source (음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구)

  • Jang, Hansol;Kim, Gyeong Hun;Han, Ga-Hee;Cho, Jaedu;Kim, Chang-Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Time-encoded near-infrared spectroscopy (NIRS) system is proposed, based on a near-infrared (NIR) swept laser source, for comparison to the conventional NIRS method using a detector-type spectrometer. The cavity of the NIR swept laser source consists of a semiconductor optical amplifier (SOA) with a gain region around 800 nm, and several fiber-optic components. To change the output wavelength in time using an applied electric radio-frequency signal, an acousto-optic tunable filter (AOTF) is introduced in the fiber ring cavity configuration. To demonstrate the feasibility of an NIR swept laser source for NIRS imaging, the spectroscopic comparison of two kinds of absorbance-measuring systems a detector-type spectrometer using a white light source, and a source-type spectrometer using an NIR swept laser is successfully performed with an NIR-absorbing dye.

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

Toxic Optic Neuropathy Caused by Chlorfenapyr Poisoning (클로르페나피르 음독 후 발생한 독성 시신경병증 1예)

  • Park, Su Jin;Jung, Jae Uk;Kang, Yong Koo;Chun, Bo Young;Son, Byeong Jae
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1097-1102
    • /
    • 2018
  • Purpose: To report a case of toxic optic neuropathy caused by chlorfenapyr ingestion accompanied by central nervous system involvement. Case summary: A 44-year-old female visited our clinic complaining of reduced visual acuity in both eyes for 7 days. She had ingested a mouthful of chlorfenapyr for a suicide attempt 2 weeks prior to the visit. Gastric lavage was performed immediately after ingestion at the other hospital. Her best-corrected visual acuity was finger count 30 cm in the right eye and hand motion in the left eye. Both pupils were dilated by 5.0 mm and the response to light was sluggish in both eyes. A relative afferent pupillary defect was detected in her left eye. Funduscopy revealed optic disc swelling in both eyes. Magnetic resonance imaging of the brain showed a symmetric hyper-intense signal in the white matter tract including the internal capsule, corpus callosum, middle cerebellar peduncle, and brainstem. The patient was diagnosed with toxic optic neuropathy induced by chlorfenapyr ingestion, and underwent high-dose intravenous corticosteroid pulse therapy. Three days later, the best-corrected visual acuity was no light perception in both eyes. Three months later, optic atrophy was observed in both eyes. Optical coherence tomography revealed a reduction in the thicknesses of the retinal nerve fiber layer and ganglion cell and inner plexiform layer in the macular area. Conclusions: Ingestion of even a small amount of chlorfenapyr can cause severe optic nerve damage through the latent period, despite prompt lavage and high-dose steroid treatment.

Black ginseng extract ameliorates hypercholesterolemia in rats

  • Saba, Evelyn;Jeon, Bo Ra;Jeong, Da-Hye;Lee, Kija;Goo, Youn-Kyoung;Kim, Seung-Hyung;Sung, Chang-Keun;Roh, Seong-Soo;Kim, Sung Dae;Kim, Hyun-Kyoung;Rhee, Man-Hee
    • Journal of Ginseng Research
    • /
    • v.40 no.2
    • /
    • pp.160-168
    • /
    • 2016
  • Background: Ginseng (Panax ginseng Meyer) is a well-characterized medicinal herb listed in the classic oriental herbal dictionary as "Shin-nong-bon-cho-kyung." Ginseng has diverse pharmacologic and therapeutic properties. Black ginseng (BG, Ginseng Radix nigra) is produced by repeatedly steaming fresh ginseng nine times. Studies of BG have shown that prolonged heat treatment enhances the antioxidant activity with increased radical scavenging activity. Several recent studies have showed the effects of BG on increased lipid profiles in mice. In this study report the effects of water and ethanol extracts of BG on hypercholesterolemia in rats. To our knowledge, this is the first time such an effect has been reported. Methods: Experiments were conducted on male Sprague Dawley rats fed with a high-cholesterol diet supplemented with the water and ethanol extracts of BG (200 mg/kg). Their blood cholesterol levels, serum white blood cell levels, and cholesterol-metabolizing marker genes messenger RNA (mRNA) expression were determined. Liver and adipose tissues were histologically analyzed. Results: We found that BG extracts efficiently reduced the total serum cholesterol levels, low-density lipoprotein (LDL) levels with increased food efficiency ratio and increased number of neutrophil cells. It also attenuated the key genes responsible for lipogenesis, that is, acetyl-coenzyme A (CoA) acetyltransferase 2, 3-hydroxy-3-methyl-glutaryl-CoA reductase, and sterol regulatory element-binding protein 2, at the mRNA level inside liver cells. Furthermore, the BG extract also reduced the accumulation of fat in adipose tissues, and inhibited the neutral fat content in liver cells stained with hematoxylin and eosin and oil red O. Conclusion: Administration of BG extracts to Sprague Dawley rats fed with high-cholesterol diet ameliorated hypercholesterolemia, which was mediated via modulation of cholesterol-metabolizing marker genes. This data throw a light on BG's cardioprotective effects.

Clinical Practice Guideline for Endoscopic Resection of Early Gastrointestinal Cancer (조기위장관암 내시경 치료 임상진료지침)

  • Park, Chan Hyuk;Yang, Dong-Hoon;Kim, Jong Wook;Kim, Jie-Hyun;Kim, Ji Hyun;Min, Yang Won;Lee, Si Hyung;Bae, Jung Ho;Chung, Hyunsoo;Choi, Kee Don;Park, Jun Chul;Lee, Hyuk;Kwak, Min-Seob;Kim, Bun;Lee, Hyun Jung;Lee, Hye Seung;Choi, Miyoung;Park, Dong-Ah;Lee, Jong Yeul;Byeon, Jeong-Sik;Park, Chan Guk;Cho, Joo Young;Lee, Soo Teik;Chun, Hoon Jai
    • Journal of Digestive Cancer Research
    • /
    • v.8 no.1
    • /
    • pp.1-50
    • /
    • 2020
  • Although surgery was the standard treatment for early gastrointestinal cancers, endoscopic resection is now a standard treatment for early gastrointestinal cancers without regional lymph node metastasis. High-definition white light endoscopy, chromoendoscopy, and image-enhanced endoscopy such as narrow band imaging are performed to assess the edge and depth of early gastrointestinal cancers for delineation of resection boundaries and prediction of the possibility of lymph node metastasis before the decision of endoscopic resection. Endoscopic mucosal resection and/or endoscopic submucosal dissection can be performed to remove early gastrointestinal cancers completely by en bloc fashion. Histopathological evaluation should be carefully made to investigate the presence of risk factors for lymph node metastasis such as depth of cancer invasion and lymphovascular invasion. Additional treatment such as radical surgery with regional lymphadenectomy should be considered if the endoscopically resected specimen shows risk factors for lymph node metastasis. This is the first Korean clinical practice guideline for endoscopic resection of early gastrointestinal cancer. This guideline was developed by using mainly de novo methods and encompasses endoscopic management of superficial esophageal squamous cell carcinoma, early gastric cancer, and early colorectal cancer. This guideline will be revised as new data on early gastrointestinal cancer are collected.